630315_1 AF700 Builders and Architects Sheet
Product Dimensions
All outside dimensions taken from the appliance are
with the standos attached.
693mm
593mm*
711mm*
596mm
387mm
AF700 Information Sheet for Builders and Architects
Appliance Information
For further information or specications, visit the
technical section of our website www.escea.com
to view the latest product Installation Manual.
Specications
Heat Output 5-5.6 kW
Star Rating 3-4 stars
Gas Input/Consumption 22-25 MJ/hr
Gas Connection Rear right or front right, 1/2”BSP female thread
Gas Type Natural Gas / ULPG (NZ) / Propane (Aus)
Weight 45 kg
Room fan Yes
Flue Type Simpson Duravent Direct Vent (False Chimney)
Flexi Flue (Masonry)
Flue Size 6” mm Outer, 4” mm Inner (Direct Vent)
4” and 3” Flexi Flue (Masonry)
Power Requirement 3 pin earthed 230V power outlet +isolating switch
to be within 1.0m of rear right hand corner of the
appliance.
Smart Heat App Yes
*Slim Fascia Dimensions.
Distance from fireplace base
to Fascia face
False cavity Installation
Cavity Construction
Masonry Installation Requirements
The masonry install requires a spacer below the appliance
to allow room for the fascia to sit flush with the ground.
Cavity Base
This appliance MUST be fully supported on its
base. The base must extend over the entire area of
the underside of the appliance. The base must also
be levelled to prevent vibration from possible fan
imbalance. M5 Standos (circled in the diagram
below) may be used to screw in any feet with an
M5 thread to level the rear of the fireplace inside
the cavity. The base of the cavity must be strong
enough to support 75kgs.
Cavity Shape
The stando rails installed on the outside must only be re-
moved when being installed into a masonry cavity.
Note: a top is not required when creating the cavity
Height Width Depth
False Chimney
installation (top standos
must be adjusted to the
upright position)
600mm 695mm 390mm
+flue
clearances
Masonry install with
Stando Rails Removed
585mm 685mm 385mm
*Note: If cavity dimensions significantly exceed those spec-
ified, a register plate is available for purchase through your
local escea retailer (New Zealand Only).
D