SUTO S520 Manuel

English
Instruction and operation manual
S520
Portable Dew Point Meter

Dear Customer,
Thank you for choosing our product.
Please read the operating instructions in full and carefully observe it
before starting up the device. The manufacturer cannot be held liable
for any damage that occurs as a result of non-observance or non-
compliance with this manual.
Should the device be tampered with in any manner other than a
procedure that is described and specified in the manual, the warranty is
cancelled and the manufacturer is e empt from liability.
The device is designed e clusively for the described application.
SUTO offers no guarantee for the suitability for any other purpose.
SUTO is also not liable for consequential damage resulting from the
delivery, capability or use of this device.
2 S520

Table of contents
1 Safety instructions......................................................................5
2 Registered trademarks.................................................................7
3 Application.................................................................................8
4 Features....................................................................................8
5 Technical data.............................................................................9
5.1 General................................................................................9
5.2 Electrical data.....................................................................10
5.3 Accuracy ...........................................................................10
6 Dimensional drawing..................................................................11
7 Installation...............................................................................12
7.1 Installation procedure..........................................................13
7.2 Electrical connection............................................................14
7.3 Replacing the sensor unit......................................................15
8 Operation.................................................................................16
8.1 Buttons and connectors........................................................16
8.2 Symbols on screen..............................................................17
8.3 Home screen ......................................................................18
8.3.1 Home Screen operations.................................................18
8.4 Menu.................................................................................19
8.4.1 Device settings..............................................................22
8.4.2 Sensor Settings.............................................................23
8.4.3 Logger.........................................................................24
8.4.4 Files.............................................................................24
8.4.5 Device info....................................................................25
8.4.6 Service info...................................................................26
8.4.7 Site information.............................................................26
8.4.8 Wireless printer.............................................................27
8.5 Graph................................................................................27
8.6 Print files............................................................................28
8.7 Smart features....................................................................29
8.8 E port logger files to a PC.....................................................30
8.9 Update the device Firmware..................................................30
9 Application software .................................................................32
9.1 S4A...................................................................................32
10 Optional accessories................................................................33
10.1 Wireless printer CS2 (A1372)..............................................33
10.1.1 Paper loading..............................................................33
10.1.2 Basic operations..........................................................34
10.2 Measuring chambers for the S520........................................35
10.2.1 Standard measuring chamber (A699 3500).....................35
10.2.2 By-pass measuring chamber (A699 3501).......................35
S520 3

11 Calibration..............................................................................36
11.1 Dew point calibration..........................................................36
11.2 Pressure calibration ...........................................................36
12 Maintenance...........................................................................36
13 Disposal or waste....................................................................37
4 S520

1 Safety instructions
1 Safety instructions
Please check if this instruction manual matches the
product type.
Please observe all notes and instructions indicated in this
manual. It contains essential information which must be
observed before and during installation, operation, and
maintenance. Therefore this instruction manual must be read carefully
by the technician as well as by the responsible user/qualified personnel.
This instruction manual must be available at the operation site of the
dew point meter at any time. In case of any obscurities or questions,
regarding this manual or the product, please contact the manufacturer.
ARNING!
Compressed air!
Any contact with quickly escaping air or bursting
parts of the compressed air system can lead to
serious injuries or even death!
•Only use pressure tight installation material.
•Avoid that persons get hit escaping air or bursting parts of the
instrument.
•The system must be pressure-less during maintenance work.
ARNING!
Voltage used for supply!
Any contact with energized parts of the product may
lead to an electrical shock, which can lead to serious
injuries or even death!
•Consider all regulations for electrical installations.
•The system must be disconnected from any power supply during
maintenance work.
•Any electrical work on the system is only allowed by authorized
qualified personal.
S520 5

1 Safety instructions
ATTENTION!
Permitted operating parameters!
Observe the permitted operating parameters. Any
operation exceeding this parameters can lead to
malfunctions and may lead to damage on the
instrument or the system.
•Do not e ceed the permitted operating parameters.
•Make sure the product is operated in its permitted limitations.
•Do not e ceed or undercut the permitted storage and operating
temperature and pressure.
General safety instructions
•It is not allowed to use the product in e plosive areas.
•Please observe the national regulations before/during installation
and operation.
Remarks
•It is not allowed to disassemble the product.
•Always use a spanner to mount the product properly.
ATTENTION!
Measurement values can be affected by malfunction!
The product must be installed properly and
frequently maintained. Otherwise, it may lead to
wrong measurement values, which can result in
wrong results.
Storage and transportation
•Make sure that the transportation temperature of the dew point
meter is between -30 ... +70°C.
•For transportation it is recommended to use the packaging that
comes with the sensor.
•Please make sure that the storage temperature of the sensor is
between -20 ... +50°C.
•Avoid direct UV and solar radiation during storage.
•For the storage the humidity must be <80% rH with no
condensation.
6 S520

2 Registered trademarks
2 Registered trademarks
SUTO®
Registered trademark of SUTO iTEC
MODBUS®
Registered trademark of the Modbus Organization, Hopkinton, USA
HART®
Registered trademark of the HART Communication Foundation, Austin,
USA
PROFIBUS®
Registered trademark of the PROFIBUS User Organization, Karlsruhe,
Germany
S520 7

3 Application
3 Application
The S520 is a dew point meter that is designed to monitor the dew
point in the industrial application within the permissible operating
parameters. These parameters can be found in the Technical data
chapter on page 9.
The S520 can measure and display the following values for compressed
air or gas:
•Dew point, default unit: °C Td
•Humidity, default unit: °C Td
•Temperature, default unit: °C
•Pressure, default unit: bar (g)
The S520 dew point meter is mainly used in compressed air systems in
industrial environments. It is not developed to be used in e plosive
areas. For the use in e plosive areas please contact the manufacturer.
4 Features
•Measures dew point, temperature, humidity, and pressure
•Two sensor solutions available:
◦Sensor A: Standard sensor unit with a range of
-100 … +20°C Td
◦Sensor B: Economic sensor unit with a range of
-50 … +50°C Td
•Smart dew point prediction
•Integrated pressure sensor
•Modern colour touch screen interface
•Data logger, USB interface, and Bluetooth connection to a portable
printer
•Measuring/parking chamber, designed for fast sensor response
•Application software included
•Integrated camera for more elegant reports
•ISO8573-1 Class indication
8 S520

5 Technical data
5 Technical data
5.1 General
Parameters Standard unit dew point: °C Td
Standard unit temperature: °C
Other units: °F, K
Standard unit humidity: % rH
Standard unit pressure: bar(g), MPa(g)
Principle of measurement Capacitive method, Oscillating crystal
Sensor Sensor A: QCM + Polymer
Sensor B: Polymer
Temperature: Pt100
Pressure: Piezo resistive type (only with
Sensor A1370)
Measuring medium Air, CO2, N2, Argon (CO2 measurements with
the A1371 module are limited to -40 °C Td)
Measuring range Sensor A: -100 … +20°C Td
Sensor B: -50 … +50°C Td
Pressure: 0 … 1.5 MPa (g)
Temperature: -30 … +50°C
Operating temperature Medium: -30 … +50°C
Ambient: 0 … +40°C
Operating pressure -0.1 … 1.6 MPa (g) *
Humidity Medium: 0 … 90% rH
Ambient: 0 … 80% rH
Casing material PC + ABS
Protection class IP65
Dimensions See dimensional drawing on page 11
Display 3.5” color LCD touch screen
Weight 2.7 kg complete set in transport case
Camera 5.0 megapi els (only with smart features
option)
Data Logger Integrated mass storage, 100 Million values
Process connection G1/2” for direct sensor connection,
S520 9

5 Technical data
Measuring chamber with 6 mm hose quick
coupling
* At least 0.3 MPa(g) is needed for the measuring chamber supplied with
the instrument. For low-pressure measuring below 0.3 MPa(g), choose
the optional bypass measuring chamber A699 3501.
5.2 Electrical data
Power supply USB charger: 5 V, 2 A
Connector: USB-C
Battery Operating time on one charge: ~8 h
Charging time until full: ~3 h
5.3 Accuracy
Accuracy Dew point:
± 1 °C Td (0 … 20°C Td)
± 2 °C Td (-60 … 0 / +20 … +50°C Td)
± 3 °C Td (-100 … -60°C Td)
Temperature:
± 0.3 °C
Pressure:
0.5 % FS
Repeatability ± 0.5°C
Stated accuracy at Ambient/process temperature: 23°C ± 3°C
Ambient humidity: 0 … 80% rH, no
condensation
10 S520
Table des matières
Autres manuels SUTO Instrument de mesure
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur



































