SUTO S 120 Manuel

English
Instruction and operation manual
S120
Oil Vapor Monitor

Dear Customer,
Thank you for choosing our product.
Before you start up the device, please read this manual in full and
carefully observe instructions stated. The manufacturer cannot be held
liable for any damage that occurs as a result of non-observance or non-
compliance with this manual.
Should the device be tampered with in any manner other than a
procedure that is described and specified in the manual, the warranty is
void and the manufacturer is e empt from liability.
The device is designed e clusively for the described application.
SUTO offers no guarantee for the suitability for any other purpose.
SUTO is also not liable for consequential damage resulting from the
delivery, capability or use of this device.
2 S120

Table of Contents
1 Safety instructions......................................................................5
2 Registered trademarks.................................................................7
3 Application.................................................................................8
4 Features....................................................................................8
5 Technical data.............................................................................9
5.1 Measuring parameter.............................................................9
5.2 General data.........................................................................9
5.3 Electrical data.....................................................................10
5.4 Output signals.....................................................................10
6 Dimensional drawing..................................................................11
7 Installation ..............................................................................12
7.1 Installation requirements......................................................12
7.2 Wall mounting instructions ...................................................12
7.3 Installation procedure..........................................................14
7.3.1 Installation requirements................................................14
7.3.2 Installation steps...........................................................16
7.4 Electrical connection............................................................17
7.4.1 USB port.......................................................................17
7.4.2 RJ45 connector..............................................................17
7.4.3 M12 connectors.............................................................17
8 Configuration ...........................................................................20
8.1 Integrated display...............................................................20
8.2 E ternal display device ........................................................20
8.3 Service kit..........................................................................20
9 Operations using the integrated display........................................21
9.1 User interface ....................................................................21
9.1.1 Main screen..................................................................21
9.1.2 Quick buttons................................................................22
9.1.3 Status bar....................................................................22
9.2 Main menus........................................................................23
9.3 Sensor settings ..................................................................24
9.3.1 Basic setting.................................................................24
9.3.2 Analog output ..............................................................25
9.3.3 Modbus/RTU settings......................................................25
9.3.4 Modbus/TCP settings......................................................26
9.3.5 Alarm settings...............................................................26
9.3.6 Status..........................................................................26
9.4 Logger settings...................................................................27
9.5 Files...................................................................................28
9.6 Service info .......................................................................28
9.7 System settings .................................................................29
S120 3

10 Troubleshooting.......................................................................30
10.1 LED indicators...................................................................30
10.2 Error indications................................................................31
11 Signal outputs.........................................................................32
11.1 Analog output ..................................................................32
11.2 Digital output ...................................................................32
11.3 Alarm output ....................................................................33
12 Optional accessories................................................................35
12.1 Sensor display...................................................................35
12.2 Service kit .......................................................................35
13 Calibration..............................................................................35
14 Maintenance...........................................................................35
15 Disposal or waste....................................................................35
16 Warranty................................................................................36
4 S120

1 Safety instructions
1 Safety instructions
Please check if this instruction manual matches the
product type
Please observe all notes and instructions indicated in this
manual. It contains essential information which must be
observed before and during installation, operation and
maintenance. Therefore this instruction manual must be read carefully
by the technician as well as by the responsible users and qualified
personnel.
This instruction manual must be available at the operation site of the oil
vapor sensor at any time. In case of any obscurities or questions,
regarding this manual or the product, please contact the manufacturer.
WARNING!
Compressed air!
Any contact with quickly escaping air or bursting
parts of the compressed air system can lead to
serious injuries or even death!
•Do not e ceed the ma imum permitted pressure range (see
sensors label).
•Only use pressure tight installation material.
•Avoid that persons get hit by escaping air or bursting parts of the
instrument.
•The system must be pressure-less during maintenance work.
WARNING!
Voltage used for supply!
Any contact with energized parts of the product, may
lead to an electrical shock which can lead to serious
injuries or even death!
•Consider all regulations for electrical installations.
•The system must be disconnected from any power supply during
maintenance work.
•Any electrical work on the system is only allowed by authorized
qualified personal.
S120 5

1 Safety instructions
ATTENTION!
Permitted operating parameters!
Observe the permitted operating parameters, any
operation exceeding this parameters can lead to
malfunctions and may lead to damage on the
instrument or the system
•Do not e ceed the permitted operating parameters.
•Make sure the product is operated in its permitted limitations.
•Do not e ceed or undercut the permitted storage and operation
temperature and pressure.
•The product should be maintained and calibrated frequently, at
least annually.
General safety instructions
•It is not allowed to use the product in e plosive areas.
•Please observe the national regulations before/during installation
and operation.
Remarks
•It is not allowed to disassemble the product.
ATTENTION!
Measurement values can be affected by malfunction!
The product must be installed properly and
frequently maintained, otherwise it may lead to
wrong measurement values, which can lead to
wrong results
Storage and transportation
•Make sure that the transportation temperature of the device is
between -30 ... +70°C.
•For transportation it is recommended to use the packaging which
comes with the device.
•Please make sure that the storage temperature of the device is
between -20 ... +50°C.
•Avoid direct UV and solar radiation during storage.
•For the storage the humidity must be <90%, no condensation.
6 S120

3 Application
3 Application
The S120 Oil Vapor Monitor is designed to monitor oil contents and dew
point (option) in compressed air and gases within the permissible
operating parameters. These parameters can be found in the technical
data section.
The S120 is mainly used in compressed air systems in industrial
environment. The S120 is not developed to be used in e plosive areas.
To evaluate its applicability in e plosive areas, please contact the
manufacturer.
4 Features
•Measures oil vapor contents and pressure dew point (option) in
compressed air and other gases.
•Easy connection through sampling hose and quick connect.
•Applicable in the permanent or portable applications.
•Measures down to 0.001 mg/m3.
•PID sensor for the highest accuracy.
•Optional dew point sensor with dual-sensor technology for high
accuracy over the whole range from –100 ... +20 °C Td (option).
•Service and alarm indication through LEDs.
•Connectable to display and data logger of SUTO as well as third-
party display and control units.
•IP65 casing provides robust protection in rough industrial
environment.
•Optional local display for showing actual readings without e tra
cable connection.
•Supports multiple interfaces for signal outputs and electrical
connections.
8 S120

5 Technical data
5 Technical data
5 1 Measuring parameter
Parameter Unit Range Resolution Accuracy
Oil vapor mg/m30.001 ... 5.000
mg/m3 *
0.001 mg/m³ 5% of reading ± 0.003
mg/m3
Pressure bar(g) 0 … 16 bar(g) 0.01 bar(g) 0.5% FS
Temperature °C 0 … 50°C 0.1°C 0.5°C
Dew point
(Option)
°C Td -100 ... +20°C Td 0.1°C Td ±1°C Td (0 ... 20°C Td)
±2°C Td (-70 ... 0°C Td)
±3°C Td (-100 ... -70°C
Td)
* Based on 1000 hPa(a), 20°C, 0% relative humidity
5 2 General data
Principle of measurement •Photo ionization
•Oscillating crystal (option)
Sensor •PID (photo ionization detector)
•Piezzo resistive pressure sensor
•QCM + Polymer (option)
Measuring medium Compressed air and gases free of corrosive,
aggressive, caustic and flammable
constituents
Sample flow range < 2 l/min, measuring gas is released to
ambient
Operating temperature -20 ... +50°C
Gas humidity < 40% rel. humidity, no condensation
Operating pressure 3 ... 15 bar(g) (higher pressure on request)
Low pressure (optional) 0.5 ... 2 bar(g)
Housing material PC, Al alloy
Protection class IP65
Dimensions See dimensional drawing on page 11.
S120 9

5 Technical data
Display (optional) 5” color touch screen with a data logger of
100 million measurement values
Weight •2.4 kg
•2.58 kg (with option A1250)
UV lamp lifetime 6,000 working hours or 1 year, whichever
comes first
5 3 Electrical data
Power supply 24 VDC ± 5%, 10 W
5 4 Output signals
Analog output 4 ... 20 mA
Alarm output Relay, NO, 40 VDC, 0.2 A
Digital interface RS-485, Modbus/RTU,
Ethernet, Modbus/TCP, USB (available for
display version)
10 S120
Autres manuels pour S 120
2
Table des matières
Autres manuels SUTO Instrument de mesure
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur