Operation
The HE-RS01 has five relays and five external inputs (S1, S2, S3, S4, S5).
1. Each relay can be controlled by any external input or via a Z-Wave network (using a Z-Wave gateway).
2. Each external input can be configured to control any relay output state (from one to five) in the modes below:
1) MOMENTARY (factory default mode): When the button on an external switch is held, the relay output turns ON.
As soon as the button is released, the relay output state changes to OFF (see Parameters 41-45 settings).
2) MOMENTARY REVERSED: When the button on an external switch is held, the relay output turns OFF. As soon
as the button is released, the relay output state changes to ON (see Parameters 41-45 settings).
3) MOMENTARY TOGGLE: When the button on an external switch is held, the relay output inverts state (from ON
to OFF or from OFF to ON), as soon as the button is released the relay output inverts state again (see
Parameters 41-45 settings).
4) TOGGLE: Press button on external switch: relay output inverts state: (ON to OFF) or (OFF to ON).
5) SWITCH ON ONLY: Press button on external switch: relay output switches to ON state
(i.e. contacts are closed).
6) SWITCH-OFF: Press button on external switch: relay output switches to OFF state
(i.e. contacts are opened).
7) TIMER: ON>OFF: Press button on external switch: relay output switches to ON for the specified time, then
reverts to OFF. (Tip: This function is useful to open/close garage doors, blinds, curtains, etc.)
8) TIMER REVERSED: OFF>ON: Press button on external switch: relay output switches to OFF for the specified
time then reverts to ON. (Tip: This function is useful for switching off security systems for a short time.)
Note: Time can be configured from 0 to 12 hours (0 to 43200 seconds).
9) TWO-RELAY INVERSE: When two relays are in Inverse mode, after pressing a button on external switch the
corresponding relay (connected to that button) inverts its state: (from ON to OFF, or from OFF to ON) and the
second relay will be switched OFF.
Note: In this mode both relays cannot be switched ON simultaneously. Can be used for motor direction control.
10) ROLLER SHUTTER: When two relays are connected to the same external switch, they will operate in ‘roller
shutter’ mode. After entering this mode, relays will switch to OFF state, and never switch ON simultaneously.
The four-cycle relay behavior is as follows (in this order):
• 1st press: first relay will be switched ON, second relay will be switched OFF
• 2nd press: both relays will be switched OFF
• 3rd press: second relay will be switched ON, first relay will be switched OFF
• 4th press: both relays will be switched OFF
The above-mentioned two relays are defined according to parameters 101 & 102 (e.g. if “54” is set as the
parameter value, it means the fifth relay and fourth relay will be operated in inverse mode).
Note: This can be used to control motor directions with one button only.
Switches connected to external inputs (terminals S1-S5) can also be used to run scenarios or change modes in the
connected gateway or associated devices.
If the HE-RS01 is associated with a Z-Wave gateway, the scene controller and five binary switches will appear. The
scene controller indicates which external input was pressed, held, or released and allows the running of scenes on the
Z-Wave gateway. The five binary switches allow the relay outputs to be managed.
Scenarios
Scenarios can be created that allow connected devices to be triggered by the HE-RS01 onboard Real Time Clock
(RTC). The user should configure the output number, state, time, state change condition, in the Parameters (from 111
- 120) which will trigger the scenes.
Power and Energy Consumption
The HE-RS01 monitors all connected loads active (i.e. ‘real time’) power, and total energy consumption, through
software energy consumption logic. This data is periodically reported to the main Z-Wave controller according to
Parameter 04.
Total Energy Consumption is the electrical power being used by connected device in real time during use. Power
usage is calculated by the software using the values that were manually set when configuring Parameters 12-16,