TSI Instruments DUSTTRAK 8533 Instructions d'installation

Exposure Monitoring
Model 8533/8534
DUSTTRAK™ DRX Aerosol Monitor
Operation and Service Manual
P/N 6001898, Revision E
March 2010

Copyright ©
TSI Incorporated / 2008–2010 / All rights reserved.
Limitation of Warranty and Liability (effective July 2000)
Seller warrants the goods sold hereunder, under normal use and service as described in the
operator's manual, shall be free from defects in workmanship and material for twenty-four (24)
months, or the length of time specified in the operator's manual, from the date of shipment to the
customer. This warranty period is inclusive of any statutory warranty. This limited warranty is
subject to the following exclusions:
a. Hot-wire or hot-film sensors used with research anemometers, and certain other components
when indicated in specifications, are warranted for 90 days from the date of shipment.
b. Parts repaired or replaced as a result of repair services are warranted to be free from defects
in workmanship and material, under normal use, for 90 days from the date of shipment.
c. Seller does not provide any warranty on finished goods manufactured by others or on any
fuses, batteries or other consumable materials. Only the original manufacturer's warranty
applies.
d. Unless specifically authorized in a separate writing by Seller, Seller makes no warranty with
respect to, and shall have no liability in connection with, goods which are incorporated into
other products or equipment, or which are modified by any person other than Seller.
The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated
herein. NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR
PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE.
TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER OR
BUYER, AND THE LIMIT OF SELLER'S LIABILITY FOR ANY AND ALL LOSSES,
INJURIES, OR DAMAGES CONCERNING THE GOODS (INCLUDING CLAIMS BASED
ON CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY OR OTHERWISE) SHALL
BE THE RETURN OF GOODS TO SELLER AND THE REFUND OF THE PURCHASE
PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR REPLACEMENT OF THE
GOODS. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES. SELLER SHALL NOT BE
RESPONSIBLE FOR INSTALLATION, DISMANTLING OR REINSTALLATION COSTS
OR CHARGES. No Action, regardless of form, may be brought against Seller more than 12
months after a cause of action has accrued. The goods returned under warranty to Seller's
factory shall be at Buyer's risk of loss, and will be returned, if at all, at Seller's risk of loss.
Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND
LIABILITY, which contains the complete and exclusive limited warranty of Seller. This
LIMITATION OF WARRANTY AND LIABILITY may not be amended, modified or its terms
waived, except by writing signed by an Officer of Seller.
Service Policy
Knowing that inoperative or defective instruments are as detrimental to TSI as they are to our
customers, our service policy is designed to give prompt attention to any problems.

i
CONTENTS
SAFETY INFORMATION ................................................................... III
Laser Safety......................................................................................iii
Labels...............................................................................................iv
Description of Caution/Warning Symbols.........................................iv
Caution.......................................................................................iv
Warning......................................................................................iv
Caution and Warning Symbols......................................................... v
Reusing and Recycling..................................................................... v
CHAPTER 1 UNPACKING AND PARTS IDENTIFICATION ........... 1
Unpacking the DUSTTRAK™DRX Aerosol Monitor........................... 1
Parts Identification for the DUSTTRAK™ DRX Desktop Aerosol
Monitor Model 8533....................................................................... 5
Parts Identification for the DUSTTRAK™ DRX Handheld Aerosol
Monitor Model 8534....................................................................... 6
CHAPTER 2 SETTING UP................................................................ 7
Supplying Power to the DUSTTRAK™DRX Aerosol Monitor.............7
Installing the Batteries in 8533 Desktop..................................... 7
Installing the Batteries in 8534 Handheld .................................. 7
Using the AC Adapter to Run Instrument................................... 8
Battery Charging........................................................................ 8
Inlet Cap..................................................................................... 8
Instrument Setup .............................................................................. 9
Connecting to the Computer...................................................... 9
Installing TRAKPROTM Data Analysis Software ........................... 9
Connecting Analog/Alarm Output ............................................ 10
Wiring the Analog Output ............................................................... 10
Wiring the Alarm............................................................................. 11
CHAPTER 3 OPERATION.............................................................. 13
Getting Started................................................................................ 13
Setup Menu .................................................................................... 14
Zero Cal.................................................................................... 15
Flow Cal ................................................................................... 16
User Cal ................................................................................... 17
Alarm........................................................................................ 22
Analog...................................................................................... 25
Settings .................................................................................... 26
Run Mode................................................................................. 28
Survey Mode............................................................................ 29
Manual Mode ........................................................................... 30
Log Mode (1–5)........................................................................ 31

ii
Taking Mass Concentration Measurements...................................32
Screen Regions........................................................................33
Stats .........................................................................................34
Graphing...................................................................................36
Viewing Data...................................................................................38
Title Bar...........................................................................................39
CHAPTER 4 MAINTENANCE.........................................................41
Maintenance Schedule...................................................................41
Zeroing Instrument..........................................................................42
Cleaning the Inlet............................................................................43
Cleaning 2.5 µm Calibration Impactor............................................44
Replacing the Internal Filters..........................................................45
Storage Precautions .......................................................................49
CHAPTER 5 TROUBLESHOOTING...............................................51
APPENDIX A SPECIFICATIONS...................................................55
APPENDIX B DRX ADVANCED CALIBRATION..........................57
Option 1: Serial Gravimetric Calibration .........................................57
Step 1: PCF Calibration............................................................57
Step 2: SCF Calibration............................................................57
Option 2: Parallel Gravimetric Calibration ......................................58
APPENDIX C ZERO MODULE ......................................................61
INDEX ................................................................................................63