TRAK 3ntr Series Manuel utilisateur

TRAK®3ntr 3D Printers
SPFU Installation Quick Start Guide
Covers Current Models:
•3ntr A2
•3ntr A4
2615 Homestead Place
Rancho Dominguez, CA 90220-5610 USA
T | 310.608.4422 |F | 310.764.2668
Service Department: 800.367.3165
e-mail: sales@trakmt.com | service@trakmt.com | web: www.trakmt.com
Document: P/N 32230
Version: 111919

Copyright ©2019, Southwestern Industries, Inc. All rights are reserved. No part of this publication may
be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, mechanical,
photocopying, recording or otherwise, without the prior written permission of Southwestern Industries,
Inc.
While every effort has been made to include all the information required for the purposes of this guide,
Southwestern Industries, Inc. assumes no responsibility for inaccuracies or omission and accepts no
liability for damages resulting from the use of the information contained in this guide.
All brand names and products are trademarks or registered trademarks of their respective holders.
Southwestern Industries, Inc.
2615 Homestead Place
Rancho Dominguez, CA 90220
Phone 310-608-4422 Fax 310-764-2668
Service Department
Phone 800-367-3165 Fax 310-886-8029

i
TRAK Machine Tools
Southwestern Industries, Inc.
TRAK 3ntr 3D Printers –SPFU Installation Quick Start Guide
Table of Contents
1Introduction ...............................................................1
2Clean Nozzle Procedure ..............................................1
2.1 Clean Nozzle Procedure Overview:....................................................... 1
2.2 Unload Filament Using Change Filament Function............................... 1
2.3 Load Cleaning Filament ........................................................................ 5
2.4 Nozzle Cleaning (Automated Function)................................................ 7
3Install SPFU to Nozzle #1 .........................................11
4TRAK Warranty Policy...............................................20

1
TRAK Machine Tools
Southwestern Industries, Inc.
TRAK 3ntr 3D Printers –SPFU Installation Quick Start Guide
1Introduction
This guide outlines the process to install the Soft Polymer Feeder Unit (SPFU) to Nozzle #1 of your TRAK
3ntr A2 or A4 printer. Before you can install the SPFU, you must complete the Clean Nozzle procedure
(also outlined within this guide).
2Clean Nozzle Procedure
This section details all the steps to clean extruder nozzles. The nozzle cleaning procedure must ALWAYS
be performed BEFORE changing to a new polymer type filament. A nozzle cleaning procedure should
always be performed any time there are unacceptable nozzle flow conditions that cannot be cleared with
several purge cycles.
2.1 Clean Nozzle Procedure Overview:
There are three steps to cleaning nozzles;
1) Remove existing filament(s) using the change filament function
2) Feed cleaning filament (nylon) to the extruder(s)
3) Clean nozzle(s) using the front panel control Clean Nozzle function
CAUTION - Only load factory recommended (nylon or equivalent) filament for cleaning procedures.
NOTE - Before using the Clean Nozzle function from the front panel, you must use the Change/Load
Cleaning Filament procedure to remove build/support filament and feed the nylon cleaning filament to the
extruders to be cleaned.
2.2 Unload Filament Using Change Filament Function
In this section, you will change filament removing existing spools before installing the cleaning filament
(instead of a new build/support material filament spool). It should always be performed before a nozzle
cleaning procedure.
NOTE - If you are using an MMS unit or PolyBox (humidity-controlled container) the process is different.
If feeding material directly from a PolyBox or equivalent container, follow the instructions as applicable
1) Check that there is enough clearance (20-30mm) between nozzle and plate before starting. If
not, move printer plate following instructions for “Move Z axis function”
2) Navigate to the Prepare menu. From the Prepare menu select “Change filament”

2
TRAK Machine Tools
Southwestern Industries, Inc.
TRAK 3ntr 3D Printers –SPFU Installation Quick Start Guide
Figure 2.2.1 Selecting Change Filament from Prepare Menu
3) Assuming filament has been previously loaded, Select Change Filament “Extruder #1”
Figure 2.2.2 Selecting Extruder for Change Filament
4) The selected extruder will begin heating up and the LCD will display Heating… Observe the
temperature readout for the selected extruder and see it increasing.
Figure 2.2.3 Info Display During Change Filament
5) Once the set temperature is reached, the machine will purge some filament. Once this automatic
purging is completed, the display will indicate “Unload Filament Now”. At this time, you can now
reach to the back of the cabinet to unload the filament.
Figure 2.2.4 Printer Readiness Signal to Change Filament Spool
6) Locate the feeder handle on the selected extruder. Grab the feeder handle of the selected
extruder, push it down and secure it into position with the provided lock “lip” This way the feeder
mechanism will be disengaged. Looking at the feeders from the rear of the printer, the rightmost
is the #1 feeder, and leftmost is #3.

3
TRAK Machine Tools
Southwestern Industries, Inc.
TRAK 3ntr 3D Printers –SPFU Installation Quick Start Guide
Figure 2.2.5 Disengage filament feeder
Figure 2.2.6 Latched & Unlatched Filament Feeders

4
TRAK Machine Tools
Southwestern Industries, Inc.
TRAK 3ntr 3D Printers –SPFU Installation Quick Start Guide
7) Pull the filament from the feeder, rewinding the filament onto the spool.
Figure 2.2.7 Pulling old filament out of feeder unit
8) Thread the end through the opening on the spool to keep it from de-coiling.
Figure 2.2.8 Secure filament end to spool
9) Unlock and remove collar from filament spool spindle of selected extruder on back of printer.
Remove filament spool and place in a dry and clean container (with desiccant package) away
from heat and sunlight.

5
TRAK Machine Tools
Southwestern Industries, Inc.
TRAK 3ntr 3D Printers –SPFU Installation Quick Start Guide
2.3 Load Cleaning Filament
1) Obtain the cleaning filament (Hollow nylon filament specially for nozzle cleaning).
Figure 2.3.1 Nozzle Cleaning Filament (Nylon)
2) Trim off several mm to remove bends, dirt, tape, or damage. Straighten as needed.
Figure 2.3.2 Trim off the end of new filament
3) Use scissors, knife, or a pencil sharpener to point the filament end for easy feeding to the
extruder.
Figure 2.3.3 Illustration of correct and incorrect filament tip sharpening

6
TRAK Machine Tools
Southwestern Industries, Inc.
TRAK 3ntr 3D Printers –SPFU Installation Quick Start Guide
4) Feed the filament into the feeder unit and keep feeding until the end stops at the extruder.
Release the feeder handle. Verify the locking “lip” is disengaged.
Figure 2.3.4 Engage the filament feeder
5) The locking lip is now engaged. The machine will automatically control the filament feed.
Figure 2.3.5 Latched and Unlatched Filament Feeders

7
TRAK Machine Tools
Southwestern Industries, Inc.
TRAK 3ntr 3D Printers –SPFU Installation Quick Start Guide
6) Press the button on the jog wheel. The LCD will display “Priming #X” as it purges some filament.
Upon completion, the LCD will display “Change #x Complete” to indicate completion.
Figure 2.3.6 LCD Display while new filament is priming
7) Repeat filament change/load cleaning filament procedure for extruder #2 (as necessary)
8) Repeat filament change/load cleaning filament procedure for extruder #3 (as necessary)
9) Procedure complete!
2.4 Nozzle Cleaning (Automated Function)
This section details the nozzle cleaning procedure. The nozzle cleaning procedure must ALWAYS be
performed BEFORE changing to a new polymer type filament. A nozzle cleaning procedure should always
be performed any time there are unacceptable nozzle flow conditions that cannot be cleared with several
purge cycles.
NOTE - Before using the Clean Nozzle function from the front panel, you must use the Change Filament
procedure to remove build/support filament and feed the nylon cleaning filament to the extruders to be
cleaned.
1) Use CHANGE FILAMENT/Load Cleaning Filament procedure (see appropriate guide section for
instructions) to remove filament in use and to load cleaner filament to the machine.
Figure 2.4.1 Change Filament Function
Autres manuels pour 3ntr Series
7
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels TRAK Imprimante 3D

TRAK
TRAK Airwolf EVO-T Manuel de programmation

TRAK
TRAK 3ntr Series Manuel utilisateur

TRAK
TRAK 3ntr Series Manuel utilisateur

TRAK
TRAK 3ntr Series Manuel utilisateur

TRAK
TRAK 3ntr Series Manuel

TRAK
TRAK 3ntr Series Manuel utilisateur

TRAK
TRAK 3ntr Series Manuel utilisateur

TRAK
TRAK 3ntr Series Manuel de programmation

TRAK
TRAK 3ntr A2 Manuel de programmation

TRAK
TRAK Airwolf 3D EVO-T Mode d'emploi