Measurement of room humidity –scope of measurement 25% - 95%, accuracy of measurement +/- 5%, scope of display (20% - 99%)
Measurement of outdoor temperature –scope of measurement -30°C - +60°C, accuracy of measurement +/- 1°C, scope of display (-40°C - +70°C)
Measurement of outdoor humidity –scope of measurement 25%-95%, accuracy of measurement +/- 5%, scope of display (20% - 99%)
Measurement of pressure
Moon phases
Temperature alarm (warning when a certain temperature is reached)
Six levels of weather forecasting: sunny, partly cloudy, cloudy, showers, thunderstorms, snow
Option of pairing up three wireless sensors
Indication of discharge of the battery of the main unit and the wireless sensor
Comfort indicator
Adjustable under-lighting of display (high, medium, off)
Display switching on activated by sound (e.g. by clapping) or by knock on the meteorological station (only during charging using batteries)
3. FUNCTIONS AND WORKING OF DEVICE
3.1. Time setting
In the real time mode press and hold the MODE button for more than three seconds. That gets you into time setup mode. The active segment starts flashing. The
order of setup is time zone –hours –minutes –years –months –days –language - exit. Pressing the UP button moves one step forwards; pressing the button for
longer than two seconds moves forwards at a speed of eight steps per second. Pressing the DOWN button moves one step back; by pressing the button for longer
than two seconds you can move backwards at a speed of eight steps per second. Pressing the MODE button confirms the settings. If you don't press any button
for ten seconds then the values get stored the way that you set them up.
3.2. Alarm setup
In standard mode pressing the MODE button switches between real time, alarm 1 and alarm 2. Default setting: alarm 1 is at 06:00 and alarm 2 is at 00:00.
In Alarm 1 setup mode (AL1) press the MODE button and hold it for more than two seconds. That way you enter Alarm 1 setup mode. The active segment begins
to flash. Order of setup: hour → minute → exit. Press the UP button to proceed one step forwards; holding it down for longer moves through the steps faster.
Pressing the DOWN button moves one step back; holding it down for long moves through the steps faster. Pressing the MODE button confirms the setting. If you
don't press any button for ten seconds then the values get stored the way that you set them up. To set up alarm 2 (AL2) proceed in the same way.
3.3. Wake-up function
In real time mode press the ALARM button to switch the alarm on and off in the following order: Switch on Alarm 1 (AL1) –Switch on Alarm 2 (AL2) –Alarm 1
(AL1) and Alarm 2 (AL2) switched on - Alarm 1 (AL1) and Alarm 2 (AL2) switched off. When the alarm starts to ring, the symbol appears on the display and
starts flashing together with the AL alarm symbol. Pressing SNOOZE/LIGHT postpones the alarm. Pressing any other button switches the alarm off. The alarm
switches itself off automatically after two minutes. When the alarm sounds no RCC signal is received, it gets renewed after the alarm is switched off. If the same
time is set for both alarms then AL1 flashes on the display. The alarm can be postponed for a discretionary time. Alarm sound is in the following order: a) 0-10
seconds: one beep per second, b) 10 –20 seconds two beeps per second, c) after 20 seconds –four beeps per second.
3.4. Snooze setup
In standard mode pressing the SNOOZE/LIGHT button for more than three seconds switches on the snooze setting (interval set up to you from three to twenty
minutes, the default setting is five minutes). The active segment starts flashing. Pressing the UP button moves one step forwards; holding it down for longer moves
faster. Pressing the DOWN button moves one step back; holding it down longer moves faster. Pressing the MODE button confirms the setting. If you haven't
pressed any button for ten seconds, the values will be stored the way that you set them up.
3.5. Sensor switching function
In real time mode pressing the CHANNEL button switches between channels (CH1, CH2, CH3 or cyclical repetition of all three channels). During cyclical repetition
the symbol appears on the display. In cyclical repetition display of three channels mode the values change by themselves. If less than three outdoor sensors
are connected then random data are displayed during cyclical repetition on channels that are not connected.
3.6. Sensor pairing function
First you have to set up different channels on individual sensors. Open the battery cover and use the positionable switch to set channel number 1, 2 or 3. Then
insert the batteries and close the cover. When switching the meteorological station on the first time the sensors will automatically get paired. However, if you
want to change the pairing then switch channel using the CHANNEL button and then hold it for more than two seconds. The pairing takes about three minutes. If
the pairing is unsuccessful then the meteorological station is apparently beyond reach of signal.
3.7. Temperature alarm setup function
In real time mode pressing the ALERTS button switches between a warning of the highest and lowest room and outdoor temperatures in the following order:
highest outdoor temperature –lowest outdoor temperature - highest room temperature –lowest room temperature.