It is possible to connect an active safety edge on the
terminal M8. If this device is pressed it opens the
contact causing a partial inversion of the movement
both in opening and in closing. If not used bridge
the contacts 1 and 2 of M8. Note: contact N.C.
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
Limit switch
For the functioning the presence of both limit
switches in closing and in opening is necessary.
Encoder / Ammeter sensor
The encoder is a device that allows to reveal possible obstacles during the opening and the closing of
the gate. When this device intervenes in opening it causes the inversion of the movement for around
a second, if it intervenes in closing it causes the total reopening.
Note 1: Such function is active through an ammeter sensor on the control board. It is not
necessary to mount any external devices for the respect of legislation.
Note2: The ammeter sensitivity is adjustable both in opening and in closing through the
JOLLY terminal. On the control unit the torque can be adjusted in 4 steps: low, middle,
middle high, high and will be the same in opening and closing. With high torque the gate
reverses after 5 seconds.
Attention: after each intervention of the ammeter sensor it is necessary to give a start impulse
to restore the movement.
Costa di sicurezza
1 2
M8
For the right functioning of the limit switch, the movement direction of the motor and the
respective busy limit switches must correspond. Through DIP3 it is possible to
exchange contemporarily the direction of the motor and of the limit switches.
Note: if during programming phase the motor and limit switch times should not
be in phase between them, the gate will start in closing, it stops and will not
complete the selflearning of the times, at this point it will be necessary to
switch off the tension and to invert the cables of the motor and to eventually
exchange the motor direction on DIP 3. The first movement in selflearning must
always be executed in closing.
Com = Common
C = Contact
M4
1 2
1 2
JOLLY functions:
1) With the Jolly programmer such function is tied up to the presence of at least
one limit switch and it’s possible to activate the function anti-intrusion. When the
limit switch is free it forces the motor to re-close.
2) With the Jolly programmer it is possible to exchange the motor and the limit
switch without setting DIP3 of the control unit.
JOLLY functions:
It is possible to activate a pre-flashing of 3 seconds before activating the automation, on setting pre-
flashing on ON, through the Jolly programmer. Furthermore from the flashing lamp it is possible to verify
some alarm signals. See alarms indications.
Through the Jolly programmer it is possible to set this exit with fixed flashing also when the gate is not
moving or it is possible to change this exit into control lamp. In such case all the indications of alarm
remain on the warning lamp as long as they are active.
JOLLY FUNCTIONS:
It is possible to activate the balanced edge 8K2, in this
case the edge contact will be controled by a specific
value of resistance revealing the eventuel unintentional
short circuit of the device. In case of an unbalance of the
device the corresponding led of the terminal board M8
will flash quickly.
ENCODER - LIMIT SWITCH
JOLLY functions: With the JOLLY programmer the torque parameters can be adjusted linearly
from 10% to 100% on each single motor. Furthermore, they are differentiable between opening and
closing.
Flashing Lamp 24V 15W (Warning lamp )
The warning lamp advises that the automatic gate is moving with 1 flash /second in opening and 2
flashes / second in closing. During pause it remains fixed on.
Connect the cables of the warning lamp as shown in the figure. The pre-flashing function can be
activated with the Jolly terminal or with Led 4 of the menu through the SET and MENU buttons.
SECURITY EDGE AND WARNING LAMP
English
USER 1 - 24V
67411070
Limit
Switch
M4
M8
Limit
Switch
REV 01 - 12/2010 23