OneFex KZ-02AL Manuel utilisateur

KZ-02AL User Manual
1
KZ-02AL I/O Module
User Manual
V3.0

KZ-02AL User Manual
2
Product features...........................................................................................................................3
1. Testing Preparation....................................................................................................................4
2. Function Introduction.................................................................................................................4
2.1 Overview.............................................................................................................................4
2.2 Product Specifications........................................................................................................4
3. Hardware Wiring ........................................................................................................................5
3.1 Power Supply Wiring..........................................................................................................5
3.2 Analog Input Wiring ...........................................................................................................5
3.3 Digital Input Wiring ............................................................................................................7
3.4 Digital Output Wiring .........................................................................................................7
3.5 Terminal Definition.............................................................................................................8
4. Config Tool Guide ......................................................................................................................8
4.1 Login....................................................................................................................................8
4.2 Search and add devices......................................................................................................9
4.3 Model Importing ..............................................................................................................11
4.4 Revise Device Info.............................................................................................................12
4.5 Build &Revise Group.........................................................................................................13
4.6 Add/Delete Models..........................................................................................................14
5Built-in Webpage Configuration .........................................................................................15
5.1 Login..................................................................................................................................15
5.2 Fixed IP..............................................................................................................................15
5.3 Protocol Convert...............................................................................................................17
5.4 Network Parameter Setting..............................................................................................18
5.5 Unmodifiable Items..........................................................................................................19
6Product Maintenance...........................................................................................................20
7After-sale Service .................................................................................................................20
7.1 Commitment.....................................................................................................................20
7.2 Disclaimer .........................................................................................................................21

KZ-02AL User Manual
3
Product features
Support 2 relay outputs;;
Support 2-way input, compatible with wet and dry nodes;;
Support 2 channels of 4-20ma analog acquisition;
The RS485 serial port is reserved for slave mode, which can be connected to other
Modbus RTU master devices;
Adopt Modbus TCP protocol data processing;
Support to connect to private cloud;
Support hardware watchdog with high reliability;
Multiple indicator lights show working status;
Support input and output logic mode selection;
Support relay output timing and delay settings;
Support camera access, real-time live broadcast;
Support device sharing, multiple users monitor at the same time;
Support query and view of historical data

KZ-02AL User Manual
4
1. Testing Preparation
This test needs to a KZ-02AL, a DC12V/1A power supply, and a router (with
Internet access). The hardware diagram is as follows:
Note: The device is dynamic IP by default. A router (with Internet access) is
recommended to test the connection.
①In the case of power failure, connect the supporting network cable to the device.
②Use the matching power adapter to supply power to KZ-02AL.
2. Function Introduction
2.1 Overview
KZ-02AL is 2*DO&2*AI&2*DI.
KZ-02AL can be widely used in farms, agricultural greenhouses, IoT terminals,
water conservancy, electricity, gas collection and control and other application
scenarios, its unique logic control function can easily realize automatic water supply,
fertilization, start and stop valves It is an ideal device for small automatic control
scenes.
KZ-02AL has RS485 interface, 2-channel DO relay output, 2-channel analog
acquisition input, 2-channel digital switch value acquisition, and supports 9~60V wide
voltage power supply.
2.2 Product Specifications
⚫Dimensions: 103.8 × 100 × 27 (mm)
⚫Power supply interface: 5.5*2.1cm round plug, positive inside and negative
outside
⚫Working voltage: DC9V~60V
⚫Working current: 100mA MAX
⚫Working temperature: -40℃~85℃
⚫Working humidity: 10%~90% non-condensing

KZ-02AL User Manual
5
3. Hardware Wiring
3.1 Power Supply Wiring
The module supports 9-60V working voltage (typical value: DC12V, DC24V)
①The module can be powered directly by the power adapter. The size of the
round head socket is 5.5*2.1cm, and the inside is positive and outside negative.
When using this method to supply power, all VIN+/VIN- of the device will also be
charged, which can supply power to active sensors.
②All VIN+ and VIN- interfaces on the module are also internally connected to the
power input interface, and any set of interfaces can also supply power to the device or
active sensors.
After the power connected normally, WORK light of the module flashes green;
network port light is always on in green and flashes in orange.
3.2 Analog Input Wiring
Two-wire analog sensor wiring:
The positive power of the sensor → VIN+ of the module;
the negative power of the sensor → ADI1 of the module,
as shown in the following figure:

KZ-02AL User Manual
6
Three-wire analog sensor wiring:
The positive power of the sensor → the VIN+ of the module;
The Negative power of sensor → VIN- of module;
The signal of the sensor → the ADI of the module,
as shown in the following figure:
Four-wire analog sensor wiring:
The positive of the sensor → the VIN+ of the module;
The negative of the sensor → the VIN- of the module;
The signal negative of the sensor → the VIN- of the module;
The signal positive of the sensor → the ADI of the module.
If the power of the sensor is large, it is not recommended that the sensor take
power from the module, and an additional power supply is required.
as shown in the following figure:

KZ-02AL User Manual
7
3.3 Digital Input Wiring
KZ-02AL has 2 channels (dry node access) for digital switch value acquisition.
The signal form is passive switch input.
If two-wire digital sensor, the negative of sensor needs to be connected to VIN- of
the module, and the signal line is connected to the DI acquisition port;
If three-wire sensor, the positive of sensor connect to VIN+ of the module, the
negative to VIN- of the module, and the signal wire to the DI acquisition port of
module.
Simple test: short-circuit DI1 and VIN- to achieve the first channel switch signal
acquisition.
3.4 Digital Output Wiring
KZ-02AL controller has 2 relay output interfaces. Each relay has 3 terminals,
NOX is normally open port, COMX is common port, NCX is normally close port.
Maximum operating current: 7A
Maximum switching current: 10A
The following figure is schematic diagram of wiring, that is, the two ends of fire
wire are connected to the NO and COM terminals of module respectively.

KZ-02AL User Manual
8
3.5 Terminal Definition
Port function
Identification
Function description
ADC INPUT
VIN+
Positive power supply
VIN-
Negative power supply
ADI1
Analog acquisition port 1
ADI2
Analog acquisition port 2
DI INPUT
VIN+
Positive power supply
VIN-
Negative power supply
DI1
Digital Input1
DI2
Digital Input2
DO OUTPUT
NO1
Normally Open 1
COM1
Public port 1
NC1
Normally close 1
NO2
Normally Open 2
COM2
Public port 2
NC2
Normally close 2
RS 485
VIN+
Positive power supply
VIN-
Negative power supply
A/+
RA485A
B/-
RA485B
4. Config Tool Guide
4.1 Login
Open Devicekey.exe, type password(admin) to login.

KZ-02AL User Manual
9
4.2 Search and add devices
Search then AddDevice,and enter the device information, which in accordance with
the module.

KZ-02AL User Manual
10
After the addition is complete, go back to the home page, you can control the switch
and read the data of the module.
Among them, AI1 is the collected value of analog quantity 1, and AI2 is the collected
value of analog quantity 2;
DI1 is the acquisition value of the first channel switch signal, DI2 is the acquisition
value of the first channel switch signal;
AI1-liml is the lower limit value corresponding to analog quantity 1, and AI1-limh is the
upper limit value corresponding to analog quantity 1. After filling in this value, the
analog value acquisition (AI1) displays the converted real value;
AI2-liml is the lower limit value corresponding to analog quantity 2, and AI2-limh is the
upper limit value corresponding to analog quantity 2. After filling in this value, the
Table des matières
Autres manuels OneFex Unité de contrôle
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur