Microcyber NCS-TT106H-R1 Manuel utilisateur

NCS-TT106H-R1 HART DIN Rail
Temperature Transmitter
User Manual

http://www.microcyber-fieldbus.com
Warning
1. It is forbidden for users to disassemble the temperature
module by themselves.
2. Please check if the supply voltage of temperature transmitter
meets the power supply voltage requirements in themanual

http://www.microcyber-fieldbus.com
Catalogue
1. BRIEF INTRODUCTION......................................................................................... 1
2. INSTALLATION......................................................................................................2
2.1 DIMENSION................................................................................................................................ 2
2.2 WIRING 2
3. HART TEMPERATURE TRANSMIITER CONFIGURATION.......................................4
3.1TOPOLOGY CONNECTION........................................................................................................... 4
3.2 FUNCTIONAL CONFIGURATION...................................................................................................5
4 MAINTENANCE...................................................................................................16
5 TECHNICAL SPECIFICATION................................................................................ 17
1.1 BASIC PARAMETER.................................................................................................................. 17
1.2 RTD PARAMETER.................................................................................................................... 18
1.3 THERMOCOUPLE...................................................................................................................... 18
1.4 PHYSICAL PARAMETER.............................................................................................................19

http://www.microcyber-fieldbus.com
1
HART DIN Rail Temperature Transmitter | NCS TT106H R1 | Page
Email | fang.siqi@microcyber.cn
1. BRIEF INTRODUCTION
NCS-TT106H-R1 fieldbus temperature transmitter, using the
fieldbus technology, is a new generation of smart fieldbus
temperature transmitter and it is an indispensable field device for
process control. NCS-TT106H-R1 integrates abundant function blocks
and realizes not only general measurement function but also
complicated control strategy.
NCS-TT106H-R1 uses digital technology, so it can connect with
many types of thermocouple and thermo resistive sensors. It has
wide range and simple interface between field and control room,
which reduces the expense of installation, operation and
maintenance.

http://www.microcyber-fieldbus.com
2
HART DIN Rail Temperature Transmitter | NCS TT106H R1 | Page
Email | fang.siqi@microcyber.cn
2. INSTALLATION
2.1 Dimension
Figure 2.1 Dimension of Temperature Transmitter (Unit: mm)
2.2 Wiring
Figure 2.3 Wiring

http://www.microcyber-fieldbus.com
3
HART DIN Rail Temperature Transmitter | NCS TT106H R1 | Page
Email | fang.siqi@microcyber.cn
Fieldbus temperature transmitter power and bus signal share a pair of
cable, and it is called bus cable. It is suggested the user use fieldbus
special cable recommended by IEC61158-2.
The signal cable and bus cable cannot share wires or wire slot
with other device power wire, and they shall be away from device
with high power.
The shielded wires of bus ends shall be connected to the ground.

4
http://www.microcyber-fieldbus.com
HART DIN Rail Temperature Transmitter | NCS TT106H R1 | Page
Email | fang.siqi@microcyber.cn
3. HART TEMPERATURE TRANSMIITER
CONFIGURATION
3.1 Topology Connection
The connection mode of HART smart transmitter can be divided
into 4~20mA compatible mode and networking mode.
4~20mA compatibility mode (as shown in Figure 3.1)
Power
Field
Communicator
Features:
Figure 3.14~20mA compatible mode
1) Access to the upper level control system through the AI
module and HART communication device;
2) Mixed use of analog and digital communication methods;
3) The device address is 0.
HART
Modem
Host or DC

5
http://www.microcyber-fieldbus.com
HART DIN Rail Temperature Transmitter | NCS TT106H R1 | Page
Email | fang.siqi@microcyber.cn
Networking mode (as shown in Figure 3.2)
Host or DCS
Field Communic tor
I/O system
Features:
Figure 3.2 HART Networking mode
1) Access to the upper level control system through the HART
communication device;
2) Using only the digital function of the HART system, the
current on the line is fixed at 4 mA;
3) Supports up to 64 device networking in short address format.
3.2 Functional configuration
The intelligent temperature transmitter supports Baldota
Corporation's HartMPT configuration software, HART FCG's SDC625
and other general HART configuration software for configuration
debugging. The following is an example of Baldota's HartMPT
configuration software to introduce the configuration method of the
intelligent temperature transmitter. It mainly includes the following
functions:
1) Basic information configuration: configure the basic

6
http://www.microcyber-fieldbus.com
HART DIN Rail Temperature Transmitter | NCS TT106H R1 | Page
Email | fang.siqi@microcyber.cn
information of the online device, including the label, address, date,
assembly number and other information;
2) Configuration information configuration: configure the
configuration information of the online device, including the main
variable range, damping and other information;
3) Sensor information configuration: configure sensor
information of the online device, including type, line system and
other information;
4) Current calibration: It can calibrate the 4~20mA current of
the online device, and can also set the fixed current output;
5) Variable monitoring: It can periodically refresh all dynamic
variables of the selected online device and display the trend curve of
the current device host variable.
⚫
Configuration environment
1) PC with serial port, operating system is Windows
2000\Windows XP;
2) HART Modem and serial cable;
3) Matching resistance is 250Ω~550Ω.
⚫
Basic information configuration
The basic information tab allows you to read or modify the basic
information of the smart transmitter, including device address,
message, description, label, date, assembly number, alarm, write
protection, manufacturer ID, manufacturer, device type, device ID. ,
long address and version information, as shown in Figure 3.3.

7
http://www.microcyber-fieldbus.com
HART DIN Rail Temperature Transmitter | NCS TT106H R1 | Page
Email | fang.siqi@microcyber.cn
Figure 3.3 Basic Information
After the information is modified, you can download it to the
device by pressing the “Apply” button.
1) The selection range of the address is 0 to 63;
2) The message can be entered up to 32 characters;
3) Description can input up to 16 specified characters;
4) The maximum length of the label is 8 specified characters;
5) The date range is from 1900 to 2155;
6) The maximum length of the assembly number is 6 specified
characters.
⚫
Configuration information configuration
The smart transmitter configuration information can be read or
modified via the configuration information tab.
Table des matières
Autres manuels Microcyber Émetteur
Manuels Émetteur populaires d'autres marques

Dejero
Dejero EnGo 3x Manuel utilisateur

Rosemount
Rosemount 4600 Manuel utilisateur

Speaka Professional
Speaka Professional 2342740 Manuel utilisateur

trubomat
trubomat GAB 1000 Manuel utilisateur

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Manuel utilisateur

Rondish
Rondish UT-11 Manuel utilisateur