7
Note the following for grease lubrication: Every 60 hours of operation check striking mechanism, friction bearings
and antifriction bearings; if necessary, grease them. Every 300 hours of operation grease the gears and antifriction
bearings anew. In the case of impact wrenches, use a grease gun to grease the anvil guide before beginning daily work,
or every 6-8 hours.
All inner parts of the drive (tool holder must be lubricated before storing for longer periods of time in order to prevent
rusting. It is recommended to check the vanes and bearings at regular intervals. Store tools in dry rooms only.
Grease to be used:
In general: SAE 5 W to SAE 10
For impact wrenches without gear only SAE 5 W.
For saw chain greasing on chain saws: Machine oil with adhesive additive, viscosity: c ST 49-55’ (6,5-7,5 E)/ 50°C.
Greases ( free of resins and acids) Multi-purpose greases for antifriction
and friction bearings
Special greases for high-speed miter
gears
Designation in accordance with DIN
51502
Consistency class (DIN 51818)
Saponication type Dripping point
Worked penetration Temperature range
K L 2 k
2
Lithium
185 °C
265 to 295
-25°C to + 125°C
G 000 h
00
Sodium
145°C
400 to 410
-25°C to + 100°C
Oiler types used on or with our tools:
Oiler to mount on the machine or connect in the hose line
Setting the oiler: The adjustment screw item 2 is visible after removing the
screw plug item 3. Theoil supply is decreased by tightening the screw, and by
loosening the screw, more oil gets into the machine. In most cases it is sucient
to tighten or loosen the screw by ¼ or ½ of a turn. When plugged, clean
borehole (dia. 2 mm) with wire.
Correct setting; When under pressure and with the ller screw (item 4) open, the
oil must bubble slightly.
The llint lasts for approx. 8 operating hours.
Line oiler
For stationary pneumatic machines and motors, the lubrication is carried out by
lined-up oilers for horizontal or vertical installation.
Setting of oilers: Shut o air supply. Open plug item 3.
Loosen visible lock nut item 5 with a socket wrench.
Using a screw driver turn back the tightened screw plug item 4 by ¼ to ½ of a
turn and then lock again.
No oil is to get into the borehole “a” when lling. Close plug item 3 and open the
air supply.
Correct setting: A piece of paper held for a short time in front of the outlet must
be coated with oil without drops forming.
Transparent oiler
For installing in permanently equipped workplaces
(especially for type using service units – see accessories list)
The transparent supply containers allow for good checking as well as for
good setting possibility by means of a screw driver via a set screw with visible
dripping. (The set screw is above the lateral thread connection – turning to the
right for less oil; turning to the left for more oil) The setting (2 to 5 drops per
m³/min air consumption) is to be carried out when air is owing through, i.e.,
when the machine is running.