
Operating manual Digital Transmitter DTM.OCS.S / DTM.OCS.S/N
6Modbus standard commands .............................................21
6.1 Read pressure value (P)..............................................21
6.1.1 Command (Hex-Code, Function Code 4).....21
6.1.2 Interpretation start index 0: Measured
pressure value..............................................21
6.2 Read temperature-value (T).........................................21
6.2.1 Command (Hex-Code, Function Code 4).....21
6.2.2 Interpretation start index 1: Measured
temperature value.........................................21
6.3 Read pressure and temperature in one command ......22
6.3.1 Command (Hex-Code, Function Code 4).....22
6.4 Read maximum pressure (Nominal pressure, PMAX)....22
6.4.1 Command (Hex-Code, Function Code 3).....22
6.4.2 Interpretation start index 200+201:
Nominal pressure..........................................22
6.5 Read minimal pressure (Zero-point pressure, PMIN) ....23
6.5.1 Command (Hex-Code, Function Code 3):....23
6.5.2 Interpretation start index 202+203: Zero-
point pressure...............................................23
6.6 Read maximum temperature (end of temperature
range, TMAX)..................................................................24
6.6.1 Command (Hex-Code, Function Code 3).....24
6.6.2 Interpretation start index 204+205: End of
temperature range........................................24
6.7 Read minimal temperature (start of temperature
range, TMIN) ..................................................................24
6.7.1 Command (Hex-Code, Function Code 3).....24
6.7.2 Interpretation start index 206+207: Start of
temperature range........................................24
6.8 Read PMAX, PMIN, TMAX, TMIN together in one
command .....................................................................24
6.8.1 Command (Hex-Code, Function Code 3).....24
6.9 Change device’s Modbus address...............................25
6.9.1 Command (Hex-Code, Function Code 16)...25
6.10 Read serial number......................................................25
6.10.1 Command (Hex-Code, Function Code 3).....25
6.11 Read Firmware version................................................25
6.11.1 Command (Hex-Code, Function Code 4).....25
7Technical Data......................................................................27
8Maintenance..........................................................................28
8.1 Cleaning the Membrane...............................................28
8.2 Recalibration ................................................................28
8.3 Disposal .......................................................................28