SENSECAP ONE Series Manuel utilisateur

User manual/ Technical information
Seeed Technology Co., Ltd. All rights reserved. www.seeedstudio.com
The 2 Page total 49
Page
Tables of Contents
Tables of Contents .....................................................................................................................................................2
1 Product Introduction ...............................................................................................................................................4
2 Installation................................................................................................................................................................7
Packing List ..................................................................................................................................................8
Installation ....................................................................................................................................................9
2.2.1 Device Interface Introduction..........................................................................................................9
2.2.2 Connect with USB Cable ..............................................................................................................10
2.2.3 M12 Cable.......................................................................................................................................10
2.2.4 Install the device. ...........................................................................................................................12
3 Device's Operating Mode ....................................................................................................................................17
Configure the device via USB port..........................................................................................................18
SenseCAP ONE Configuration Tool .......................................................................................................19
Serial debug tool........................................................................................................................................23
4 Communication Protocols ...................................................................................................................................24
Modbus-RTU Protocol ..............................................................................................................................25
4.1.1 Modbus-RTU Protocol Message Format....................................................................................25
4.1.2 Register Address Definition ..........................................................................................................26
4.1.3 Modbus-RTU Read........................................................................................................................27
4.1.4 Noise sensor...................................................................................................................................31
ASCII Protocol............................................................................................................................................33
4.2.1 Command definition.......................................................................................................................33
4.2.2 Query Command Format ..............................................................................................................33
4.2.3 Setting Command Format.............................................................................................................34
4.2.4 Command List.................................................................................................................................34
SDI-12 .........................................................................................................................................................41
4.3.1 SDI-12 command and response ..................................................................................................41
4.3.2 SDI-12 Read ...................................................................................................................................44
5 Error code ..............................................................................................................................................................49
Modbus error code ....................................................................................................................................49
ASCII error code ........................................................................................................................................49
SDI-12 error code......................................................................................................................................49

User manual/ Technical information
Seeed Technology Co., Ltd. All rights reserved. www.seeedstudio.com
The 4 Page total 49
Page
1 Product Introduction
SenseCAP ONE is a series of all-in-one compact weather sensors, including S1000 10-in-1, S800 8-in-1,
S700 7-in-1, S500 5-in-1, S200 weather sensors. These weather sensors integrate multiple sensors into
this compact device, monitoring up to10 weather parameters: air temperature, air humidity, atmospheric
pressure, light intensity, wind speed, wind direction, precipitation, PM 2.5, PM 10,noise and CO2. The
sensors use ultrasonic to measure wind speed and wind direction, to achieve high-precision data collection,
which is easy maintenance. The equipment is designed with industry standards and can work stably in
harsh outdoor environments from -40°C to 85°C. The product supports the Modbus-RTU (RS485) and
SDI-12 protocols.
Basic parameters
Product Model
SenseCAP ONE Series (S200/S500/S700/S800/S1000)
Power Supply
12V ~ 24V (1W)
Heating Power Supply
24V (3W)
Support Protocols
RS485 (MODBUS-RTU) / SDI-12
IP Rating
IP66
Working Temperature
-40 ℃ ~ + 85℃
Working Humidity
0 to 100%RH (non-condensing)
Product Model: S500 (5-in-1)
Measurement Parameter
Measurement Range
Measurement Accuracy
Resolution
Air temperature
-40~85°C
±0.1℃
0.01°C
Air humidity
0~100%RH
±1.5%RH
0.01%RH
Barometric pressure
300~1250hPa
±50Pa
10 Pa
Wind speed
0~60 m/s(@-40 ~60℃)
±0.3m/s,(≤10m/s)
±3% of the measured value(>10m/s)
0.1m/s
Direction of the wind
0~360°(@-40~60℃)
±3.0°
0.1°
Product Model: S700 (7-in-1)
Measurement Parameter
Measurement Range
Measurement Accuracy
Resolution
Air temperature
-40~85°C
±0.1℃
0.01°C
Air humidity
0~100%RH
±1.5%RH
0.01%RH
Barometric pressure
300~1250hPa
±50Pa
10 Pa

User manual/ Technical information
Seeed Technology Co., Ltd. All rights reserved. www.seeedstudio.com
The 5 Page total 49
Page
Wind speed
0~60 m/s(@-40℃~60℃)
±0.3m/s,(≤10m/s)
±3% of the measured value(>10m/s)
0.1m/s
Direction of the wind
0~360°(@-40℃~60℃)
±3.0°
0.1°
Light intensity
0~188000 Lux
5% * reading
5Lux
Rain intensity
0~200mm/h
±10%
0.2mm/0.02mm
Product Model: S900 (9-in-1)
Measurement Parameter
Measurement Range
Measurement Accuracy
Resolution
Air temperature
-40~85°C
±0.1℃
0.01°C
Air humidity
0~100%RH
±1.5%RH
0.01%RH
Barometric pressure
300~1250hPa
±50Pa
10 Pa
Wind speed
0~60 m/s(@-40℃~60℃)
±0.3m/s,(≤10m/s)
±3% of the measured value(>10m/s)
0.1m/s
Direction of the wind
0~360°(@-40℃~60℃)
±3.0°
0.1°
Light intensity
0~188000 Lux
5% of reading
5Lux
Rain intensity
0~200mm/h
±10%
0.2mm/0.02mm
PM2.5
0~1000µg/m3
±10%@100~1000µg/m3
±10µg/m3@0~100µg/m3
1µg/m3
PM10
0~1000µg/m3
±15%@100~1000µg/m3
±15µg/m3@0~100µg/m3
1µg/m3
Product Model: S1000 (10-in-1,CO2 series)
Measurement Parameter
Measurement Range
Measurement Accuracy
Resolution
Air temperature
-40~85°C
±0.1℃
0.01°C
Air humidity
0~100%RH
±1.5%RH
0.01%RH
Barometric pressure
300~1250hPa
±50Pa
10 Pa
Wind speed
0~60 m/s(@-40℃~60℃)
±0.3m/s,(≤10m/s)
±3% of the measured value(>10m/s)
0.1m/s
Direction of the wind
0~360°(@-40℃~60℃)
±3.0°
0.1°
Light intensity
0~188000 Lux
5% * reading
5Lux
Rain intensity
0~200mm/h
±10%
0.2mm/0.02mm

User manual/ Technical information
Seeed Technology Co., Ltd. All rights reserved. www.seeedstudio.com
The 6 Page total 49
Page
PM2.5
0~1000µg/m3
±10%@100~1000µg/m3
±10µg/m3@0~100µg/m3
1µg/m3
PM10
0~1000µg/m3
±15%@100~1000µg/m3
±15µg/m3@0~100µg/m3
1µg/m3
CO2
400-5000ppm;extended
range up to 10000 ppm
土(30 ppm +3% of reading)
(extended range ±10% of reading)
1ppm
Product Model: S1020(10-in-1,noise series,the custom product)
Measurement Parameter
Measurement Range
Measurement Accuracy
Resolution
Air temperature
-40~85°C
±0.1℃
0.01°C
Air humidity
0~100%RH
±1.5%RH
0.01%RH
Barometric pressure
300~1250hPa
±50Pa
10 Pa
Wind speed
0~60 m/s(@-40℃~60℃)
±0.3m/s,(≤10m/s)
±3% of the measured value(>10m/s)
0.1m/s
Direction of the wind
0~360°(@-40℃~60℃)
±3.0°
0.1°
Light intensity
0~188000 Lux
5% * reading
5Lux
Rain intensity
0~200mm/h
±10%
0.2mm/0.02mm
PM2.5
0~1000µg/m3
±10%@100~1000µg/m3
±10µg/m3@0~100µg/m3
1µg/m3
PM10
0~1000µg/m3
±15%@100~1000µg/m3
±15µg/m3@0~100µg/m3
1µg/m3
Noise intensity
30~130dB
±1.5dB
0.1dB
Note: Multi-in-one meteorological environment sensors with other monitoring elements can be
customized. For specific requirements, please contact relevant personnel of the company.

User manual/ Technical information
Seeed Technology Co., Ltd. All rights reserved. www.seeedstudio.com
The 8 Page total 49
Page
Packing List
Number
Parts
Number
1
SenseCAP ONE All-in-one compact weather sensor
1
2
M12 8-pin communication cable (default length 3-meter hook-up wire, and there
is a waterproof aviation connector type to choose when working with SenseCAP
SensorHub datalogger. If the aviation connector is not needed, cut it off by
yourself)
1
3
USB Type-C cable, for configuring devices
1
4
Flange plate (purchased separately)
1
5
Pole adapter sleeve base (purchased separately)
1
6
Pole adapter cross bar (purchased separately)
1

User manual/ Technical information
Seeed Technology Co., Ltd. All rights reserved. www.seeedstudio.com
The 9 Page total 49
Page
Installation
2.2.1 Device Interface Introduction
There are two connectors at the bottom of the device.
•USB Type-C interface allows you to connect your computer with a normal USB Type-C cable to the
device for configuration.
•The main data interface can be connected to the M12 8-pin cable, supporting multiple bus protocols
Bottom of the device

User manual/ Technical information
Seeed Technology Co., Ltd. All rights reserved. www.seeedstudio.com
The 10 Page total 49
Page
2.2.2 Connect with USB Cable
Note: The white caps should be screwed down after commissioning, to prevent water from the device!
2.2.3 M12 Cable
The device adopts an M12 8-pin connector, the different colored pins provide power and data
communication (as shown in the above diagram).
When working with the RS-485, you can connect only 4 wires (not using a heating function), and the rest
can be individually wrapped with tape to prevent short circuit
Ce manuel convient aux modèles suivants
7
Table des matières
Autres manuels SENSECAP Station météorologique
Manuels Station météorologique populaires d'autres marques

National Geographic
National Geographic VA Colour RC Manuel utilisateur

Renkforce
Renkforce 1208067 Manuel utilisateur

Levenhuk
Levenhuk Discovery Report WA40 Manuel utilisateur

Instant Transmission
Instant Transmission MA 10410 Manuel utilisateur

Lutron Electronics
Lutron Electronics PHB-318 Manuel utilisateur

WAREMA
WAREMA EWFS Weather station eco Manuel utilisateur