SBS FM10 Manuel utilisateur

FM10
FM EXCITER/TRANSMITTER
TECHNICAL MANUAL

Page 2
CONTENTS
1 Introduction
2 Safety, Electrical hazard
3 Safety, Toxic hazard
4 Unpacking
5 Controls and Connectors
6 Installation
7 Alignment
8 Specifications
19 How to contact Eddystone Broadcast Limited
10 Technical Section Contents
11 Declaration of conformity
No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical,
including photocopying, recording or information storage and retrieval systems, for any purpose other than the
purchaser's personal use, without the express written permission of sbs.
Information in this document is subject to change without notice and does not represent a commitmentonthepartof
Eddystone Broadcast Limited. Eddystone Broadcast Limited shall not be liable forany direct, indirect, consequential
or incidental damages as a result of the use or misuse of this equipment, handbook or any related materials.

Page 3
1 Introduction
──────────────────────────────────
The Eddystone Broadcast Limited FM10 has been designed for groups looking for
low power FM transmission equipment. It can include a high quality deviation limiter
and stereo encoder. With the addition of a low-cost aerial it is all that is needed to get
on air.
Because of the broadband design of the unit, no tuning is required. Frequency setting
is by means of internal, direct reading dial up switches. Output is automaticallymuted
during lock-up time.
The stereoversionis availablewithits own high qualitydeviationlimiterandcoder. This
can be offered as an upgrade for the mono FM10. The unit will operate into any SWR
without damage, with an effective VSWR protection circuit which reduces the output
power if necessary to protect the amplifier.

Page 4
2 Safety, Electrical hazard
──────────────────────────────────
This unit contains high voltages which could be fatal. YOU MUST ALWAYS ISOLATE
THE UNIT FROM THE MAINS SUPPLY BY COMPLETELY DISCONNECTING IT
BEFORE ATTEMPTING TO OPEN THE CASE.
THIS EQUIPMENT MUST BE EARTHED.
Do not expose this equipment to rain or any other source of moisture.
In common with all mains operated equipment, only suitably trained competent
personnelshouldattempt toadjust,modifyorrepairthisequipmentoroperateitwiththe
cover removed. In case of query please contact your local agent or Eddystone
Broadcast Limited.
Any unauthorised adjustment, modification or repair of this equipment may invalidate
any warranty and/or safety approvals that apply.
Please read all of this manual and familiarise yourself with the controls before
attempting to use this equipment.
To ensure safety, it isthe responsibilityof the user to installand operatethis equipment
in a manner that is within the manufacturers specifications.

Page 5
3 Safety, Toxic hazard
──────────────────────────────────
This equipment includes devices which contain Beryllium Oxide which is a highly toxic
substance. Inhalation or ingestion of even tiny particles could be injurious to health or
even FATAL!
Extreme care must be exercised whenreplacingand discardingcomponentswhichmay
contain Beryllium Oxide. If any such device is physically damaged you should seek
expert advice, e.g. by contacting the device's manufacturers.
All such devices must be disposed of in accordance with local regulations. In the UK
yourlocal councilwillhavea toxicwastedisposaldepartment who willbe abletoadvise
you. Elsewhere you should contact the responsible authorities.
NEVERDISPOSEOF A DEVICECONTAININGBERYLLIUMOXIDEWITH GENERAL
WASTE.

Page 6
4 Unpacking
──────────────────────────────────
This package should contain:-
1x FM10 Series broadcast exciter/transmitter
1x IEC Mains lead
1x FM10 series manual
If any items are missing or damaged please inform your supplier immediately.
Initial Checks
Ensure that the FM10 has been set to the correct mains/line voltage for your country.
The standard version is set to 230V.

Page 7
5 Controls and Connectors
──────────────────────────────────
Front Panel:
POWER Mains power is applied.
LIMIT The audio input level is high enough for the limiter to reduce its
level (where fitted).
Rear Panel:
Audio input Unbalanced on female BNC connector without internal limiter or
balanced on female XLR connector with optional limiter (pin2 hot,
3 cold and 1 ground).
EXT MPX Loop Multiplex output (unbuffered) on BNC connector, switchable
multiplex input on BNC connector. If switch is in ON position, the
multiplex is disconnected internally. If switch is in OFF position,
the external multiplex input is disabled and the multiplex signal is
connected internally.
Monitor 25 way female D-type.
Pin 1 Power supply OK
Pin 2 Forward power OK
Pin 4 Mute RF output
Pin 5 - 24 reserved.
Pin 25 Ground
The power supply OK and forward power OK outputs are open
collector and are normally low/ON in the normal condition. The Mute
input should be grounded to mute the output. This connector is not
normally fitted on cable distribution versions.
O/P Monitor Monitor of RF output (approx. -40dBc). This output should not be
used to measure harmonic/spurious levels.
RF Out 50Ω N type female connector.
Power Multi turn power control.
Mains Filtered IEC male connector with T1A fuse in pull out drawer.

Page 8
6 Installation
──────────────────────────────────
The FM10 is normally supplied ready aligned, therefore installation should be straight
forward. Before installation please read the section of this manual about Electrical
safety.
RF leadsshould be made from high qualitylow losscable and connectorsof thecorrect
impedance, using the manufacturers recommended termination techniques. Since
connectors are a source of unreliability in anysystem, the numberof terminationsin any
RF lead should be kept to a minimum.
Allothercablesforaudio and control signals should behighqualityscreened types. For
XLR connectors, the screen should be connected to the connector body.

Page 9
7 Alignment
──────────────────────────────────
The FM10isusuallysuppliedreadyalignedandthereforethefollowingstepsshouldnot
normally be necessary:-
7.1 Frequency setting
7.2 Output power/level
7.3 Forward power alarm
7.4 Modulator input level
7.5 DLM3 PCB
7.6 LimX PCB
When an automatic change over system is in use (such as the ACU3) this should be
disconnected/overridden such that the FM10 operates continuously during the set-up
procedure.
7.1 FREQUENCY SETTING
Setting the frequency is a simple operation. Direct reading dials are located on the
PLL7 PCB. For example, to set a frequency of 107.30MHz, set the 10MHz dial to 0,
the 1MHz dial to 7, the 100kHz dial to 3 and the 12.5kHz dial to 0. For 98.35 set
10MHz dial to 9, the 1MHz dial to 8, the 100kHz dial to 3 and the 12.5kHz dial to 4 (4
x 12.5kHz = 50kHz).
Whilst the Phase Locked Loop is Locking up the modulator output is muted
(indicated by the PLL LOCK LED on the PLL7 PCB). When the FM10 is either
powered up or the frequency changed, it will normally take about 5 seconds for the
PLL to lock up. However if the frequency is changed from a high one to one at the
bottom of the band, with the unit in operation, it can take up to 10 seconds for the
PLL to attain lock.

Page 10
7.2 OUTPUT POWER/LEVEL
Asmall trimmer toolorprecisionscrewdriverwillbe requiredtoadjusttheoutputpower.
The control is located on the rear panel.
The output power should be set using an accurate power meter connected to the RF
output which in turn should be connected to an adequately rated dummy load. If a
dummy load is not available then the FM10 could be set upconnected to the aerial. In
this case the Output Power control should be set to minimum (anti-clockwise) before
powering up the FM10.
7.3 FORWARD POWER ALARM
This setting defines the point at which a forward power fault is indicated at the
Control/Monitor socket (for telemetry and/or operation of an automatic change over
system). This is not adjustable on the FM10. It is pre-set to about 3W.
7.4 MODULATOR INPUT LEVEL
The setting of the modulator AUDIO LEVEL control (on the PLL7 PCB) will depend on
the version supplied. For the FM10/M please read the section below headed DLM3
PCB and for the FM10/S please read the section headed LimX PCB. An accurate
deviation meter will be required, which should be connected to the rear panel RF
monitor socket (or output on the cable distribution version).
Mono/MPX version (no limiter or stereo encoder)
The FM10 is normally supplied with the modulator input level set so that an input level
of +8dBu over the range 5Hz to 100kHz (without pre-emphasis) gives a deviation of
75kHz. If a different level is required then it will be necessary to reset the AUDIO
LEVEL control on the PLL7 board. Apply a 400Hz sine wave at the level required for
maximum deviation (normally 75kHz). Adjust the AUDIO LEVEL control to give the
required deviation.
Full details of the alignment procedure are available on request from Eddystone
Broadcast.
Table des matières
Autres manuels SBS Émetteur
Manuels Émetteur populaires d'autres marques

Dejero
Dejero EnGo 3x Manuel utilisateur

Rosemount
Rosemount 4600 Manuel utilisateur

Speaka Professional
Speaka Professional 2342740 Manuel utilisateur

trubomat
trubomat GAB 1000 Manuel utilisateur

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Manuel utilisateur

Rondish
Rondish UT-11 Manuel utilisateur