Perfect Prime TC0378 K Manuel utilisateur

Datalogger Thermometer
TC0378
Instruction Manual

CONTENTS
P. 1
................................................................................ 2
.................................................................................. 2
...................................................................................................... 3
........................................................................................... 4
............................................ 5 - 6
............................................. 7 - 8
............................................................................................ 8
......................................................................................... 8
................................................................................ 8 - 9
.................................................................................. 9
................................................................ 9
................................................................. 9
........................................................ 9
................................ 10
............................................... 11
...................................................................................... 12 - 13
..................................................................................... 14
............................................................................... 15
............................................................... 16 - 27
.......................................................................................... 28
1. General Description
2. Safety Information
3. Feature
4. Specifications
5. Symbol Definition and Button Location
6. Operation Instructions
6.1 Power ON/OFF & Backlight Operation
6.2 REC button
6.3 T1-T2 button
6.4 MAX/MIN mode
6.5 Data-Hold mode
6.6 Selecting temperature units
6.7 Connecting to a computer
6.8 External DC 9V power supply jack
6.9 Using the oset to compensate for probe errors
6.10 Select thermocouple type: K, J, E, or T
7. Data Logger
8. Setting the Time
9. Power Preparation8
10. Testlink SE-378 Software
11. Maintenance

1. GENERAL DESCRIPTION
2. SAFETY INFORMATION
P. 2
Thank you for choosing our Data Logger thermometer. To ensure the
safety and the best performance of this instrument, we recommend you
to read and follow the manual carefully before operation.
Test reading and measurement settings are shown on the backlit LCD
panel.
Data can be stored in the meter or directly saved on a computer through
PC interface. Recorded data can be further processed by PC computer.
Read the following safety information carefully before operate or service
the meter. Use the meter in the way specied in this manual; otherwise
the protections provided by the meter may be impaired.
ENVIRONMENT CONDITIONS
• Altitude up to 2000 meters
• Relatively humidity: 90% max
• Operation ambient temperature: -10 to 50°C
MAINTENANCE & CLEARING
• Repairs or servicing not covered in this manual should only be
performed by qualied technician.
• Periodically wipe the case with a dry cloth. Do not use abrasives
or solvents on this instrument.
MAINTENANCE & CLEARING
Comply with EMC
When servicing, use only specied replacement parts.
SAFETY INFORMATION
INTRODUCTION

3. FEATURE
P. 3
• Four channel reading LCD display
• 16,000 Records Data Logger
• PC Interface
• With Windows software
• Auto power o for battery saving
• Isolated input protection up to 250Vac between any two inputs

Measurement range:
Resolution:
Accuracy:
Temperature coefficient:
Sample rate:
Battery type:
Battery lifetime:
AC adapter:
Operation temperature:
Operation humidity:
Storage temperature:
Storage humidity:
Dimensions/ Weight:
Standard Accessories:
Optional Accessories:
K: -200 ~1372°C (- 328 ~ 2501°F)
J: -150°C~1000°C (- 238 ~ 1832°F)
E: -150°C~750°C (- 238 ~ 1382°F)
T: -180°C~400°C (- 292 ~ 752°F)
0.1°C/°F < 1000°, 1°C/°F ≥1000°
±(0.1% of reading+0.7°C) ±(0.1% of reading+1.4°F)
Below -100°C (-148°F)
±(0.4% of reading +0.7°C) ±(0.4% of reading +1.4°F)
0.01% of reading + 0.05°C per °C (<18°C or >28°C)
1 time per second
9V Battery
Approx. 30 hours (alkaline battery)
9 VDC ( 8-10VDC Max )
-10 to 50°C (14 to 122°F)
10 to 90%RH (no condensing)
-40 to 60°C (-40 to 140°F)
10 to 75%RH
197mm(L) × 65mm(W) × 36mm(H)/ Approx. 310g
Instruction manual, 9V Battery, windows software,
carrying case, USB cable, K Type Bead Probe x 2 PCS.
AC/DC adapter
Accuracy is specied for ambient temperatures between 18°C (64°F) and
28°C (82°F). The above specications do not include thermocouple
sensor error.
P. 4
4. SPECIFICATIONS

5. SYMBOL DEFINITION AND BUTTON
LOCATION
P. 5
MIN
MAX
AVG
REC
FULL
K.J.E.T
: Battery condition
indicator
: Minimum indicator
: Maximum indicator
: Average indicator
: This indicates Auto Power
O is enabled
: Recording data logger
indicator
: Memory full indicator
: Thermocouple type
: Temperature reading
: Temperature measure-
ment units
: Data hold indication

5. SYMBOL DEFINITION AND BUTTON
LOCATION
P. 6
2
3
4
5
6
1
1
Thermocouple input
Display screen
Power ON/OFF and Back
light button
REC button
T1-T2 button
MAX MIN button
8
9
10
11
12
7DATA HOLD button
°C , °F button
PC Interface
External DC 9V power supply
jack
Tilt stand
Battery Compartment
2
3
4
5
6
9
10
11
12
7
8

6.1 POWER ON/OFF & BACKLIGHT OPERATION
6.1.1 Power on/off:
Press the button to turn on the meter. To turn the unit o, press
and hold button down until the screen shows “OFF 3, 2, 1,”then
the LCD screen goes o.
Note: When the unit is on, the LCD will show the following initial
information before entering the main function: Offset setting →
Current date/time →Available memory →Entering main
function. (if all offset is set to zero, offset will not be shown)
6.1.2 LCD backlight on/off:
Press to turn on the LCD backlight. This makes it easier to read in
dark environment. Press again to turn o backlight. The meter
can also turn the backlight o automatically after 30 seconds to save
battery power.
6.1.3 Auto power off:
To save battery life, by default, every time the unit is powered on, it is
under auto power o mode. The unit will power itself o after 30
minutes if there is no key operation.
Auto power o will be automatically disabled under the following 2
situations:
• When connecting to PC.
• When data logger function is in process.
6.1.4 Disabled auto power off:
1. Turn o the unit.
2. Press and hold button.
3. Press to turn on the unit.
6. OPERATION INSTRUCTIONS
P. 7

4. The LCD shows the initial information and then enters main
function.
5. Release button.
6. Make sure the auto power o symbol disappears from display
screen.
6.2 REC BUTTON
Press button to start recording data. The REC symbol will display
on the screen. To stop recording, press button again.
6.3 T1T2 BUTTON
Push this key to display T1-T2 at
the 3rd column on LCD.
(please refer to Fig.1)
6.4 MAX/MIN MODE ONLY FOR CHANNEL T1
Under this mode, the unit simultaneously monitors and stores the
maximum, minimum and average value in the memory. The unit will
keep updating/refreshing the data.
To start:
1. Press button. MAX symbol lights up on LCD, the reading shows
the maximum data.
2. Press button again to show minimum data; the MIN symbol
lights up on LCD.
Fig.1
6. OPERATION INSTRUCTIONS
P. 8

3. Press button again to show average data; the AVG symbol
lights up on LCD.
4. Press button again, the MAX and MIN symbol blinks together.
The reading shows present T1 temperature.
5. Press button again, will circular the whole process again.
To exit MAX/MIN mode:
Press and hold button for 2 seconds to exit MAX/MIN mode.
Note: When the unit is under MAX/MIN mode, , and
buttons are disabled.
6.5 DATAHOLD MODE
Press button to freeze the data shows on the LCD screen. Press it
again to exit Data-Hold mode.
Note: When the unit is in the Data-Hold mode, , , and
buttons are disabled.
6.6 SELECTING TEMPERATURE UNITS
Press the button to switch between Celsius (°C) and Fahrenheit
(°F).
6.7 CONNECTING TO A COMPUTER
The meter can be connected to PC through USB-120 USB cable
(standard accessory) to connect with a computer. There is also
RS-232 cable available and user can purchase it separately.
6.8 EXTERNAL DC 9V POWER SUPPLY JACK
Connect the AC/DC adapter (optional accessory) to use external
power.
6. OPERATION INSTRUCTIONS
P. 9
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels Perfect Prime Enregistreur de données

Perfect Prime
Perfect Prime CO2000 Manuel utilisateur

Perfect Prime
Perfect Prime TC0309 Manuel utilisateur

Perfect Prime
Perfect Prime TC0301 Manuel utilisateur

Perfect Prime
Perfect Prime TC0520 K Manuel utilisateur

Perfect Prime
Perfect Prime TC0376 Manuel utilisateur

Perfect Prime
Perfect Prime TH0165 Manuel utilisateur