Microchip Technology MPAF Manuel utilisateur

MPAF User Manual

2
Content
1. Environment Introduction.......................................................................................................4
1.1 HW Environment for Audio Product: .................................................................................................................4
1.2 HW Environment for Data Product:...................................................................................................................5
1.3 HW Environment for Bluetooth dongle:.............................................................................................................6
1.4 HW Environment for NFC Reader:....................................................................................................................6
1.5 Other HW Environment.....................................................................................................................................6
1.6 Software Environment.......................................................................................................................................6
2. Environment Configuration....................................................................................................8
2.1 Log / Com Port..................................................................................................................................................8
2.2 Product / Solution..............................................................................................................................................9
2.3 LOAD / SAVE / APPLY / EXIT...........................................................................................................................9
3. Test Item Configuration –For Audio Product .......................................................................9
3.1 Item - 20050 Initialization ................................................................................................................................10
3.2 Item - 20100 Connect DUT.............................................................................................................................10
3.3 Item –21100 Battery Test (Option) .................................................................................................................14
3.4 Item –21200 TSSI Test (Option).....................................................................................................................14
3.5 Item –22200 Button Test (Option) ..................................................................................................................14
3.6 Item –23300 HFP SPK And MIC Test (Option) ..............................................................................................17
3.7 Item –25550 Patch EEPROM (Option) ..........................................................................................................18
3.8 Item –25595 Write DUT Device Name (Option).............................................................................................19
3.9 Item –25600 Write DUT Device Address (Option) .........................................................................................20
3.10 Item –28800 Read From NFC Write To DUT (Option)...................................................................................21
3.11 Item –29000 Disconnect DUT........................................................................................................................22
4. Test Item Configuration –For Data Product........................................................................24
4.1 Item - 20050 Initialization ................................................................................................................................24
4.2 Item - 20100 Connect DUT.............................................................................................................................24
4.3 Item –21150 Battery Voltage Test (Option) ....................................................................................................27
4.4 Item –21250 RSSI Test (Option) ....................................................................................................................27
4.5 Item –21300 PTS Test (Option)......................................................................................................................28
4.6 Item –22300 ADC Test (Option) .....................................................................................................................28
4.7 Item –22400 GPIO Input / Output Test (Option).............................................................................................35
4.8 Item –22500 PWM Test (Option)....................................................................................................................40
4.9 Item –22600 Transparent Data (Option) ........................................................................................................43
4.10 Item –25500 Reference EEPROM (Option)...................................................................................................44

3
4.11 Item –25595 Write DUT Device Name (Option).............................................................................................44
4.12 Item –25820 Check The Customer UI Footprint (Option)..............................................................................46
4.13 Item –28200 Write Flash UI (Option) .............................................................................................................46
4.14 Item –28595 Write DUT Device Name (Option).............................................................................................47
4.15 Item –29000 Disconnect DUT........................................................................................................................48
5. Run Test .................................................................................................................................49
5.1 Main Run UI Layout Description .....................................................................................................................49
5.2 Scan Bluetooth Device UI ...............................................................................................................................51
5.3 Barcode Input UI .............................................................................................................................................52
5.4 NFC Detect UI.................................................................................................................................................54
5.5 Button Test UI..................................................................................................................................................57
5.6 HFP SPK And MIC Test...................................................................................................................................58
5.7 GPIO Input / Output Test.................................................................................................................................58
5.8 PWM Test........................................................................................................................................................58
6. Example –For Audio Product ..............................................................................................59
6.1 Example 1: Change DUT Device Name And Device Address ........................................................................59
6.2 Example 2: Test Button, Microphone And Speaker Assembly Status .............................................................66
6.3 Example 3: Patch DUT Parameters................................................................................................................73
7. Example –For Data Product.................................................................................................76
7.1 Example 1: Transparent Data Transfer ...........................................................................................................76
7.2 Example 2: Change Device Name..................................................................................................................79
8. Q & A ......................................................................................................................................84
8.1 AG Timeout .....................................................................................................................................................84
8.2 Dongle Timeout...............................................................................................................................................84
8.3 Open Log File Fail...........................................................................................................................................84
8.4 Patch File Not Match.......................................................................................................................................85
8.5 Wav File Not Mono..........................................................................................................................................85

4
1. Environment Introduction
MPAF (Mass Production Assembly Function Test Tool) is a tool with controller to execute device test
or configure device parameter through Bluetooth connection through air. There are two HW
environments to use this software, one is for audio product, and another is for data product. The
audio product must support Hand Free Profile (HFP). The data product must support BLEDK3 command
sets.
1.1 HW Environment for Audio Product:
Require Audio Gateway 2.X hardware with least flash code. Need EDGAR II or EDGAR III to connect
Audio Gateway 2.X to PC.
Audio Gateway 2.X
EDGAR_II
EDGAR_III
Connect Audio Gateway 2.X as bellow picture.

5
1.2 HW Environment for Data Product:
Require BM-7x-OTA with latest BLEDK3 flash code. Connect to PC by micro-USB cable
BM-7x-OTA
Micro-USB

6
1.3 HW Environment for Bluetooth dongle:
If you want scan Bluetooth device, the PC must have a Bluetooth dongle with window Bluetooth
stack. Please check PC Device manager exist correct dongle like below:
1.4 HW Environment for NFC Reader:
If you want to use NFC tag to connect device, you must have NFC Reader. MPAD only support ACS
ACR 122 Smart Card reader. Please check PC Device manager exist correct dongle like below:
*NFC tag must NFC Forum Type2 Tag.
1.5 Other HW Environment
OS requirements: MS Windows 7 SP1
Port : COM port which supports baud rate of 115200
1.6 Software Environment
Application folder contain as bellow

7
Configuration Screen

8
Run Test Screen
2. Environment Configuration
2.1 Log / Com Port
Log Folder
Press to open folder browser dialog to select folder path. Please do not include space during
the folder path. The user must have read/write permission on this folder path.
Log SN
This number is start of SN number on log content. Increased by each DUT test.
COM Port
Please select com port to connect AG. List show all com port on pc.

9
2.2 Product / Solution
Product Name
The editable Bluetooth device product name, e.g. IS1685S_305_SPK_V5.1_MPAF
Solution
The solution name of Bluetooth IC/Module, which defined by Microchip.
2.3 LOAD / SAVE / APPLY / EXIT
LOAD: Load configuration from *.mpaf file.
SAVE: Save configuration to *.mpaf file.
APPLY: check configuration and change to test screen.
EXIT: exit MPAF.
3. Test Item Configuration –For Audio Product
Support Test Item
Supported test items but it’s “Un-selected”. If you want to test these items use “ADD”to add to MP
Test Item field.
MP Test Item
Also called selected test items, these items will be testing on DUT.
ADD - - >
Add selected test item to MP Test Item field.
DEL < - -
Del selected test item from MP Test Item field.

10
3.1 Item - 20050 Initialization
Check Interface Exist Timeout
This parameter is for check AG. If AG not response after this setting time, program will show as
bellow message box, please go back to check AG is connected already.
3.2 Item - 20100 Connect DUT
3.2.1Connect Mode
Select Connect Mode
Connect DUT mode select, default mode is BARCODE, support mode SCAN, BARCODE, LINKBACK,
NFC, FIXED. User must configuration detail parameters on reference tab. LINKBACK mode do not
need configuration detail parameter.
Connect Time Out
Program waiting DUT connected time, default time is 12 second.
3.2.2SCAN
Table des matières
Autres manuels Microchip Technology Émetteur
Manuels Émetteur populaires d'autres marques

Dejero
Dejero EnGo 3x Manuel utilisateur

Rosemount
Rosemount 4600 Manuel utilisateur

Speaka Professional
Speaka Professional 2342740 Manuel utilisateur

trubomat
trubomat GAB 1000 Manuel utilisateur

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Manuel utilisateur

Rondish
Rondish UT-11 Manuel utilisateur