1.GENERAL WARNING BEFORE OPERATING THE UNIT
Please check the conformity of waste gas , water and electric infrastucture of the area to the
necessary technical parameters where the boiler will be installed.
For safe use of electricity , make sure that the grounding of the installation is isolated and
there is no phase.
Your boiler is under guarantee for 2 years against component and production defects as long
as it is used in line with the suggestions in this manual. Our company cannot be held liable
for any misuse of the product.
Please do not use the boiler out of its purpose. The boiler is designed to supply hot water
(maximum 90°C) to your heating system.
Clean air must always be provided in the area where the boiler is installed. Due to reasons of
security, the installation of the boiler to closed areas with human presence is strictly
forbidden.
Please do not operate the boiler without water. Do not feed cold water to hot boiler. If,for any
reason the boiler temprature is over 90°C do not attempt to feed cold water to the boiler until
the boiler temprature drops down to 40°C. The best solution for over heated boiler is to take
out burning coal outside of the boiler
Please do not drain the system water except repairing or during times of frost. Antifreeze
material can be added to sytem water up to 15%
During operation, the temprature difference between return and flow can be maximum 20 °C.
Water with high calcer rate is extremely dangerous for boiler and installation. In this case,
please use water softeners.Product failures as a result of blocked water passes is out of
scope of factory guarantee.
Each year,before start of heating season,the boiler’s chimney connection and internal parts
must be checked and cleansed. This will enable efficient operation of the boiler.
Please do not take hot water out of the boiler for domestic use purposes.