Page 2
Carbon Monoxide Hazard
This product burns gas to produce heat. The
appliance must be properly installed, operated, and
maintained to avoid exposure to appreciable levels
of carbon monoxide and the installer is required to
conrm that at least one carbon monoxide alarm is
installed in the living space before the appliance is put
into operation.
It is important for carbon monoxide alarms to be
installed, maintained, and replaced following the alarm
manufacturer’s instructions and applicable local codes.
AVERTISSEMENT
Danger lié au monoxyde de carbone
Ce produit brûle des gaz pour produire de la chaleur.
L’appareil requiert une installation, un fonctionnement
et une maintenance adéquates an d’éviter l’exposition
à des niveaux appréciables de monoxyde de carbone;
l’installateur est requis de conrmer qu’au moins une
alarme de détection de monoxyde de carbone est
installée dans l’espace de vie avant que l’appareil ne
soit mis en service.
Il importe que les alarmes de détection de monoxyde
de carbone soient installées, maintenues et remplacées
selon les directives du manufacturier et les codes
locaux applicables.
LAARS Heating Systems
A. General Care
Your Mighty Therm2 will require very little
Maintenance. However, as with any ne appliance
there are certain steps that should be taken to ensure
continuing optimum performance.
Keep the area around the Mighty Therm2 clean
and free from combustible materials, gasoline and
other ammable liquids and vapors.
The Mighty Therm2 must be completely isolated
and protected from any source of corrosive chemical
fumes such as trichlorethylene, perchlorethylene,
chlorine, etc.
Keep grille openings on the boiler free for proper
ventilation of interior components.
Do not obstruct or block a free ow of air to the
boiler to ensure proper ventilation.
If desired, clean the jacket surfaces with a damp
cloth and mild detergent. Do not use ammable
cleaning materials.
If sidewall vented, keep the vent terminal clear
of obstructions — do not pile snow against the vent
terminal. Clean the air lter(s) often, and then develop
an appropriate maintenance schedule.
B. Annual Inspection of Flue and Vents
Visually inspect the vent pipe once a year. Should
any deterioration exist, have the aected parts replaced
by a qualied service person.
C. Shutting Down the Mighty Therm2
1. Switch o the main electrical disconnect switch.
2. Close all manual gas valves.
3. If freezing is anticipated, drain the Mighty
Therm2 and be sure to also protect the building
piping from freezing. This step to be performed
by a qualied service person.
D. To Restart the Mighty Therm2
If drained, follow the Installation and
Operation Manual for proper lling and purging.
1. Switch o the main electrical disconnect switch.
2. Close all manual gas valves.
3. WAIT FIVE (5) MINUTES.
4. Set the aquastat or thermostat to its lowest setting.
5. Open all manual gas valves.