JRC NJT5669 Series Manuel utilisateur

NJT5677 series]
Instruction Manual
Revision: 01
Issue Date: November 28, 2011
C-band 5W BUC
[NJT5669, NJT5670, NJT5675 &
Document Part Number: IM-T5669
IM-T5669 Rev.01
Copyright © 2011, New Japan Radio Co., Ltd. All rights reserved.
This instruction manual may not be reproduced, in part or in
whole, without the permission of New Japan Radio Co., Ltd.
The specifications and information regarding the products in this
instruction manual are subject to change without notice.
All statements, information, and recommendations in this
instruction manual are believed to be accurate but are presented
without warranty of any kind, express, or implied.
Users must take full responsibility for their application of any
products.
for
NJT5669/70/75/77 series Instruction Manual Page 1

1.
2.
3.
4.
5.
NJRC strives to produce reliable and high quality microwave components.
NJRC's microwave components are intended for specific applications and
require proper maintenance and handling. To enhance the performance
and service of NJRC's microwave components, the devices, machinery or
equipment into which they are integrated should undergo preventative
maintenance and inspection at regularly scheduled intervals. Failure to
properly maintain equipment and machinery incorporating these products
can result in catastrophic system failures.
To ensure the highest levels of reliability, NJRC products must always be
properly handled. The introduction of external contaminants (e.g. dust, oil
or cosmetics) can result in failures of microwave components.
NJRC offers a variety of microwave components intended for particular
applications. It is important that you select the proper component for your
intended application. You may contact NJRC's sales office or sales
representatives, if you are uncertain about the products listed in the
catalog and the specification sheets.
Special care is required in designing devices, machinery or equipment,
which demand high levels of reliability. This is particularly important when
designing critical components or systems whose foreseeable failure can
result in situations that could adversely affect health or safety. In
designing such critical devices, equipment or machinery, careful
consideration should be given to, amongst other things, their safety
design, fail-safe design, back-up and redundancy systems, and diffusion
design.
The products listed in the catalog and specification sheets may not be
appropriate for use in certain equipment where reliability is critical or
where the products may be subjected to extreme conditions. You should
consult our sales office or sales representatives before using the products
in any of the following types of equipment.
* Aerospace Equipment
* Equipment Used in the Deep Sea
* Power Generator Control Equipment (nuclear, steam, hydraulic)
* Life Maintenance Medical Equipment
* Fire Alarm/Intruder Detector
* Vehicle Control Equipment (automobile, airplane, railroad, ship, etc.)
* Various Safety Equipment
General Caution
IM-T5669 Rev.01
NJT5669/70/75/77 series Instruction Manual Page 2

6.
General Caution (continued)
NJRC's products have been designed and tested to function within
controlled environmental conditions. Do not use products under conditions
that deviate from methods or applications specified in the catalog and
specification sheets. Failure to employ NJRC's products in the proper
applications can lead to deterioration, destruction or failure of the
products. NJRC shall not be responsible for any bodily injury, fires or
accidents, property damage or any consequential damages resulting from
the misuse or misapplication of its products. PRODUCTS ARE SOLD
WITHOUT WARRANTY OF ANY OF KIND, EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
IM-T5669 Rev.01
NJT5669/70/75/77 series Instruction Manual Page 3

Contents
This instruction manual is intended for use by trained field installers or system
engineers responsible for satellite networks.
Updated instruction manual may be available from NJRC's sales group
IM-T5669 Rev.01
22 - 23
About This Instruction Manual
This instruction manual describes C-band 5W BUC (Model No.: NJT5669,
NJT5669F, NJT5670, NJT5670F, NJT5675N, NJT5675F, NJT5677N and NJT5677F)
herein referred to as "the Unit".
This instruction manual provides information and instructions for installation and
operation of the Unit.
1. Introduction ………………………………………………………………………………
2. Safety Instructions ……………………………………………………………………
3. Packing List ………………………………………………………………………………
14 - 17
18 - 21
7 - 10
6. Installing ……………………………………………………………………………………
12 - 13
5. Physical Description …………………………………………………………………
4. Overview ……………………………………………………………………………………
7. Specification ………………………………………………………………………………
5 - 6
11
NJT5669/70/75/77 series Instruction Manual Page 4

Full C-band 5W BUC (Model No.: NJT5677N and NJT5677F) receives a reference
signal (10 MHz) and an IF signal (L‐Band: 950 to 1,825 MHz) input and transmits
an RF signal (Palapa C-band: 6.85 to 6.725 GHz) output.
NJT5677N Full C-band, N-type female Interfece Connector
NJT5677F
Palapa C-band 5W BUC (Model No.: NJT5675N and NJT5675F) receives a
reference signal (10 MHz) and an IF signal (L‐Band: 1,065 to 1,425 MHz) input
and transmits an RF signal (Palapa C-band: 6.365 to 6.725 GHz) output.
Insat C-band 5W BUC (Model No.: NJT5670 and NJT5670F) receives a reference
signal (10 MHz) and an IF signal (L‐Band: 965 to 1,265 MHz) input and transmits
an RF signal (Insat C-band: 6.725 to 7.025 GHz) output.
Insat C-band, N-type female Interfece Connector
Insat C-band, F-type female Interfece Connector
Full C-band, F-type female Interfece Connector
The Unit comes in a single, weatherized housing rated for outdoor use. The Unit
has either an N-Type or a F-type female connector input, a WR137 waveguide
(CPR 137 grooved flange) output. The Unit is operated by +24 V DC power
(Range: +15 to +30 V) input.
This instruction manual is for C-band 5W BUC with followint model number:
NJT5669, NJT5669F, NJT5670, NJT5670F, NJT5675N, NJT5675F, NJT5677N and
NJT5677F.
1. Introduction
Standard C-band 5W BUC (Model No.: NJT5669 and NJT5669F) receives a
reference signal (10 MHz) and an IF signal (L‐Band: 950 to 1,525 MHz) input and
transmits an RF signal (Standard C-band: 5.850 to 6.425 GHz) output.
IM-T5669 Rev.01
The line-up is mentioned in a chart below.
Line-up Description
Standard C-band, N-type female Interfece Connector
Standard C-band, F-type female Interfece Connector
Palapa C-band, N-type female Interfece Connector
Palapa C-band, F-type female Interfece Connector
NJT5670
NJT5670F
Model Number
NJT5669
NJT5669F
NJT5675N
NJT5675F
NJT5669/70/75/77 series Instruction Manual Page 5

5.850
to 6.725 GHz 4.90 GHz 950
to 1,825 MHz
NJT5677F
IM-T5669 Rev.01
Local Oscillation
Frequency
IF
Frequency
Refefence
Frequency
NJT5677N
Model
Number
NJT5669 5.850
to 6.425 GHz 4.90 GHz 950
to 1,525 MHz
NJT5669F
6.725
to 7.025 GHz 5.76 GHz 965
to 1,265 MHz
NJT5670F
NJT5675N 6.365
to 6.725 GHz 5.30 GHz 1,065
to 1,425 MHz
NJT5675F
RF
Frequency
10 MHz
The detail of frequency for the reference, IF, RF and local oscillaton is mentioned
in a chart below.
NJT5670
NJT5669/70/75/77 series Instruction Manual Page 6

DANGER, WARNING, CAUTION, and NOTE statements are used throughout
this instruction manual to emphasize important and critical information. You
must read these statements to help ensure safety and to prevent product
damage. The statement are defined below.
DANGER, WARNING, CAUTION, and NOTE Statements
Use the following safety guidelines to help protect the Unit from potential damage
and to help ensure your own personal safety.
Statement Symbol Description
DANGER DANGER indicates an imminently
hazardous situation which, if not
avoided, will result in death or
serious injury.
WARNING WARNING indicates a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
CAUTION indicates a potentially
hazardous situation which, if not
avoided, could result in minor or
moderate injury. CAUTION may
also be used to indicate other
unsafe practices or risks of
property damage.
NOTE NOTE is used to notify of
installation, operation, or
maintenance information that is
important, but not hazard-
related.
IM-T5669 Rev.01
2. Safety Instructions
CAUTION
NJT5669/70/75/77 series Instruction Manual Page 7

IM-T5669 Rev.01
When installing the Unit, observe the following safety guidelines.
A radiation hazard exists if the BUC is operated with its RF
signal output unterminated.
DO NOT operate the BUC without a load or termination
attached to the RF signal output.
1. Opening / Removing
2. Input Voltage
Only input a voltage within the range indicated in specified
voltage.
DO operate at the input voltage of +15 to +30 V DC power.
Symbol Description
GENERIC HAZARD
DO NOT dismantle this product.
Dismantlement may cause malfunction and electric shock.
ELECTRIC HAZARD
HOT SURFACE
2.1. Safety Statements
3. RF Radiation
NJT5669/70/75/77 series Instruction Manual Page 8

5. Input Level
IM-T5669 Rev.01
4. High Temperatures
DO NOT input an IF signal over the range of +13 dBm
maximum and a reference signal within the range of -5 to +5
dBm.
6. Operating Temperature.
DO NOT touch the body, especially fins, during operating the
Unit.
High touch temperatures may exist, depending on load
conditions.
Operate the Unit within the ambient temperature range of -40
to +55 degree C.
2.2. Instruction Statements
1. Mounting
DO NOT block the fins.
Normally the Unit should be mounted with long fins face up.
2. Weatherproof
The Unit is mounted outdoors must be adequately
weatherproofed.
Ensure the waveguide joints are properly sealed with the
supplied o-ring (gasket).
Use self-amalgamating tape to seal connectors and cable entry
points from the connector to the cable sheath.
NJT5669/70/75/77 series Instruction Manual Page 9

DO NOT touch the filter in the waveguide output.
The filter is used for Receive band noise and spurious rejection.
If the filter is damaged or dirty, it may not reject a sufficient
value of false receive band.
IM-T5669 Rev.01
4. Connecter
Connect the IF cable to the input connector of both N and F-
type with 0.68 to 1.13 N・m torque.
5. Warranty
Opening or removing any component (e.g. label, and screws)
or sealed area will immediately void the warranty.
3. Waveguide
NJT5669/70/75/77 series Instruction Manual Page 10
Ce manuel convient aux modèles suivants
11
Table des matières
Autres manuels JRC Émetteur
Manuels Émetteur populaires d'autres marques

Dejero
Dejero EnGo 3x Manuel utilisateur

Rosemount
Rosemount 4600 Manuel utilisateur

Speaka Professional
Speaka Professional 2342740 Manuel utilisateur

trubomat
trubomat GAB 1000 Manuel utilisateur

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Manuel utilisateur

Rondish
Rondish UT-11 Manuel utilisateur