inveo RFID IND-U2 Manuel utilisateur

User manual
RFID IND-LED, RFID IND-LCD
Soft >= 0.46
User manual RFID IND-LED/LCD Pa e 1 of 51
[B04]

Dear Customer!
Thank you very much for choosin our product. Before its use, please read these
instructions carefully. Here you find the most appropriate ways of dealin with this
device, the basic principles of safety and maintenance. Please, also keep the user manual
so that you can read it durin later use.
Attention!
The manufacturer is not lia le for any damage caused y improper use of
the device which differ from its intended purpose, or improper handling, as well
as a fault of driver resulting from improper use.
User manual RFID IND-LED/LCD Pa e 2 of 51
[B04]

Ta le of contents
1 PRELIMINARY INFORMATION...................................................................................................................4
2 APPLICATIONS OF THE DEVICE................................................................................................................5
3 WARRANTY AND LIABILITY OF THE MANUFACTURER...................................................................5
4 SAFETY GUIDELINES.....................................................................................................................................6
4.1 POWER SUPPLY...................................................................................................................................................6
4.2 STORAGE, WORK CONDITIONS................................................................................................................................6
4.3 INSTALLATION AND USE OF THE READER.................................................................................................................6
4.4 UTILIZATION OF THE READER................................................................................................................................6
5 CONSTRUCTION OF THE READER............................................................................................................7
5.1 TECHNICAL DATA................................................................................................................................................7
5.2 GENERAL FEATURES............................................................................................................................................9
6 CONFIGURATION OF THE DEVICE.........................................................................................................10
6.1 CHANGING THE DE ICE'S IP ADDRESS BY DISCO ERER APPLICATION.........................................................................10
6.2 CHANGING THE PC'S SUBNET ADDRESS, FOR THE DE ICE CONFIGURATION..................................................................11
7 THE DEVICE FUNCTIONS...........................................................................................................................13
7.1 THE READER STATUS.........................................................................................................................................13
7.2 THE READER WORK MODES.................................................................................................................................14
7.3 CARDS MANAGEMENT........................................................................................................................................16
7.3.1 Add or delete a card using a network browser......................................................................................16
7.3.2 Adding cards by Modbus protocol.........................................................................................................18
7.3.3 User's own AP (HTTP GET)................................................................................................................19
7.4 ACCESS GROUPS................................................................................................................................................20
7.5 E ENTS LOG.....................................................................................................................................................22
7.6 READING MIFARE BLOCKS (REFERS ONLY TO MIFARE CLASSIC 1K/4K)....................................................................25
7.7 TEXT MESSAGES..............................................................................................................................................26
7.8 E ENTS RESPONSES – I/O SETTINGS....................................................................................................................27
7.9 REAL TIME CLOCK (RTC)................................................................................................................................30
7.10 SNMP SER ER CONFIGURATION.......................................................................................................................30
7.11 COMMUNICATIONS PROTOCOLS AND ADMINISTRATION............................................................................................31
COMMUNICATION WITH THE READER................................................................................................33
8.1 MODBUS.........................................................................................................................................................33
8.2 INTEGRATION WITH USER'S SOFTWARE...................................................................................................................38
8.3 IEWING THE READER STATUS BY HTTP GET....................................................................................................39
8.4 CONTROL BY HTTP GET PROTOCOL.................................................................................................................40
8.5 EDIT CARDS IA HTTP POST..........................................................................................................................43
8.6 CONTROLLING BY HTTP PROTOCOL IN CLIENT MODE.............................................................................................45
8.7 COMMUNICATION WITH THE READER FROM AN EXTERNAL NETWORK..........................................................................48
9 CONNECTORS DESCRIPTION....................................................................................................................49
10 DHCP................................................................................................................................................................51
11 RETURN TO THE FACTORY SETTINGS DEFAULT............................................................................51
12 THE READER SOFTWARE UPDATE.......................................................................................................51
User manual RFID IND-LED/LCD Pa e 3 of 51
[B04]

1 Preliminary information
Before starting work with the device, read The User manual and follow the
instructions contained therein!
Description of visual symbols used in this user manual:
This symbol is responsible for reviewin the appropriate place in the
user instructions, warnin s and important information. Failure to
follow warnin s could cause injury or dama e to the device
Important information and uidelines
Followin this uidelines makes the use of the device easier
Attention: The screenshots in this manual can be dissimilar from actual ima es at
the time of the device purchase. Due to continuous development of the devices
software, some of the functions may differ from these in the manual. The
manufacturer claims no responsibility for any undesirable effects (misunderstandin )
caused by chan es of the software.
User manual RFID IND-LED/LCD Pa e 4 of 51
[B04]

2 Applications of the device
Industry, services, trade, lo istics are just some of the industries in which it is possible to
use the reader. It can be used as a machine lo in tool, room access (stora e), loyalty
system component, work time recorder, etc. Usin your own application or protocols
supported by the reader the user has the ability to control practically every element of
the reader – display, buzzer, entrances, outputs. Thanks to the built-in memory, it also
has access to the list of lo s stored in it. The hi h-quality IP65 housin provides correct
operation of the reader, even if it is mounted on the facade of the buildin *.
The "RFID IND-LED/LCD" device is desi ned to read RFID ta s. RFID Standard depends
on module version:
•Mifare Classic® (ISO/IEC 14443-A) RFID IND-LED/LCD Mif
Mifare Plus® (UID), Mifare DESFire® (UID)
•Unique EM4100 EM4102 RFID IND-LED/LCD Uni
•HID iClass® (tylko CSN) RFID IND-LED/LCD iCla
•HID 125kHz RFID IND-LED/LCD H125
•ICODE® (ISO 15693) RFID IND-LED/LCD Ico
•HITAG (HITAG 2) RFID IND-LED/LCD HT2
The device is used for an inte ration with other systems by way of of modbus RTU/TCP,
HTTP client / server, SNMP protocols. The reader can also work as a standalone device.
* it is necessary to use cable land
3 Warranty and lia ility of the manufacturer
The manufacturer provides a 2-year warranty on the device. The manufacturer also
provides post-warranty service for 10 years from the date of the introducin the device
on the market. The warranty covers all defects in material and workmanship.
The manufacturer undertakes to comply with the contract of uarantee, if the followin
conditions are met:
all repairs, alterations, extensions and device calibrations are performed by the
manufacturer or authorized service,
supply network installation meets applicable standards in this re ard,
the device is operated in accordance with the recommendations outlined in this
manual,
the device is used as intended.
The manufacturer assumes no responsibility for consequences resultin from improper
installation, improper use of the device, not followin this manual and the repairs of the
device by individuals without permission.
This device doesn’t contain servicea le parts.
User manual RFID IND-LED/LCD Pa e 5 of 51
[B04]

4 Safety guidelines
The reader has been desi ned and built usin modern electronic components, accordin
to the latest trends in the lobal electronics. In particular, much emphasis was placed on
ensurin optimum safety and reliability of control.
The device has a housin with a hi h-quality plastic.
4.1 Power supply
The RFID readers require 10-24VDC power supply or optionally POE IEEE 802.3af.
4.2 Storage, work conditions.
The reader is equipped with a sealed IP65 enclosure which means:
total resistance to forei n objects
resistance to water jet directed directly to the device
stora e and operation at temperatures from -25 ° C to + 60 ° C,
4.3 Installation and use of the reader
The reader should e used following the guidelines shown in next part of the
user manual.
4.4 Utilization of the reader
When it becomes necessary to liquidate the device (for instance retirin of the device
from service), please contact the manufacturer or its representative, who are obli ed to
respond, appropriately, i.e. collectin the reader from the user. You can also ask the
companies involved in utilization and/or liquidation of electrical or computer equipment.
Under no circumstances should you place the device alon with other waste material.
User manual RFID IND-LED/LCD Pa e 6 of 51
[B04]

5 Construction of the reader
.1 Technical data
Power supply:
DC: 10-24VDC (screw terminals 3,5mm)
or PoE IEEE 802.3af (depends on the version)
or Passive PoE 12-24VDC (depends on the version)
Power consumption: max 2.5W (~200mA@12V)
Transponders:
Ta readin distance: up to 8cm from the directions of the device front side
(display or LEDs)
Wbudowana pamięć: 1000 ta ów, 30000 zdarzeń
Internal memory: 1000 ta s, 30000 events
Inputs:
number of inputs: 2
input type: opto-isolator, dry contact (NO)
Outputs:
number of outputs: 2
output type: relay NO
maximum relay current load: 1A @ 30VDC
Communication:
1 port Ethernet, 10Mbps
1 port RS485, modbus RTU
Enclosure:
IP Ratin : IP65
Dimensions:
User manual RFID IND-LED/LCD Pa e 7 of 51
[B04]

User manual RFID IND-LED/LCD Pa e 8 of 51
[B04]

.2 General features
General view of the RFID IND-LCD and RFID IND-LED is shown below.
Communication with the reader is carried out by the LAN or RS485.
User can choose from the followin options to access the code readout from a RFID ta :
–throu h built-in web server, usin a standard web browser (preferred browsers
are MOZILLA FIREFOX, OPERA, CHROME),
–HTTP server mode
–HTTP client mode
–MODBUS TCP
–MODBUS RTU (RS485)
–SNMP
The reader, dependin on the version, is equipped with an LCD display or LED diodes for
power supply indication and current state of the device.
User manual RFID IND-LED/LCD Pa e 9 of 51
[B04]
General view of the
RFID IND-LCD
General view of the
RFID IND-LED

6 Configuration of the device
The device when used for first time needs to be confi ured.
There are two methods to do so. The network confi uration can be easily chan ed by
Inveo “Discoverer” (https://inveo.com.pl/software/) software:
6.1 Changing the device's IP address by Discoverer application.
When the “Discoverer” is opened and the relevant device is found, choose Interface list
box and click on Chan e IP button.
In a new opened dialo box, settin s such
as IP address, MASK, GATEWAY, DNS1/DNS2
and the Host name can be chan ed.
Please save correct settin s by choosin
Change button.
If Remote Config is disabled (enabled by default), it is necessary to confi ure
the device by chan in the computer's subnet (chapter 6.2).
To enable the remote confi uration it is necessary to enter tabs Administration
and check mark Ena le Remote Network Config.
Save the setup by selectin Save Config button.
User manual RFID IND-LED/LCD Pa e 10 of 51
[B04]
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels inveo Autre