To reset all the column quantities.
When the display shows any ‘P’ number (i.e. ‘P3’), Push button 2 and this will then
reset ALL the column counters.
To check the total value of coins inserted.
1/ Lift the battery pack out of its location (leave connected), and beneath it you will find
a slot. Beneath the slot there is a switch on the printed circuit board (see above). Move
this switch to the on’ position (towards the back of the machine). The display shows
‘Prog’
2/ Keep pushing button 1 (the top button) until ‘P7’ is shown on the display.
3/ Push button 1 again and the display will indicate the high digits (before the decimal
point) of the cash counter.
4/ Push button 1 again to indicate ‘P8’ on the display. Pushing button 1 again will
indicate the low value of the cash counter (after the decimal point)
5/ Return the switch in 1 above to the ‘off’ position.
To run in ‘TEST’ mode
Running in test mode will allow for free vends to be made without adding to the vend counts.
To select this mode, proceed as follows:
1/ Lift the battery pack out of its location (leave connected), and beneath it you will find
a slot. Beneath the slot there is a switch on the printed circuit board (see above). Move
this switch to the on’ position (towards the back of the machine). The display shows
‘Prog’
2/ Keep pushing button 1 (the top button) until ‘P9’ is shown on the display.
3/ Pushing button 2 repeatedly toggles between ‘run’ and ‘test’ mode. ‘Run mode is for
normal operation.
4/ Return the switch in 1 above to the ‘off’ position.
Battery or mains operation
The vending machine can be operated by either battery or mains transformer. (Optional extra).
It is pre set at the factory for battery operation. To change to mains operation, proceed as
follows:
1/ Lift the battery pack out of its location (leave connected), and beneath it you will find
a slot. Beneath the slot there is a switch on the printed circuit board (see above). Move
this switch to the on’ position (towards the back of the machine). The display shows
‘Prog’
2/ Keep pushing button 1 (the top button) until ‘PA’ is shown on the display.
3/ Pushing button 2 repeatedly toggles between ‘bat’ (for battery mode) and ‘---’ (for
mains mode.).
4/ Return the switch in 1 above to the ‘off’ position.