Instruction manual H1250
HASCO hot runner 5
1. Introduction
The HASCO H 1250 control unit offers precision control and practically orientated operation.
2. Special Features
- 1 to 2 control zones
- Optimum control performance
- Programmable soft start
- Power display in amps and % output
- Clear alarm diagnosis
- Manual or automatic switch to manual mode
- Boost function
- Temperature reduction
- Thermocouple monitoring
- Heating circuit monitoring
The H 1250…control unit satisfies the key protection requirements
as per the EU Directives.
3. Technical Data
H1250/1x16 H1250/2x16 H1250/4x16
Dimensions (B x H x T) 210 x 160 x 100 210 x 160 x 100 210 x 175 x 160
Mains voltage standard 230VAC ±10% / 50 –60 Hz 400V 3N ~ ±10% / 50–60 Hz 400V 3N ~±10% / 50–60 Hz
Unit protection external 16A 16A / Phase 32A / Phase
Power output Max. 3600W Max 3600W / zone Max 3600W / zone
Thermocouple Fe-CuNi Typ J Fe-CuNi Typ J Fe-CuNi Typ J
Control range 30 –500°C 30 –500°C 30 –500°C
Control accurancy >1°C under optimum conditions >1°C under optimum conditions >1°C under optimum conditions
Ambient temperature 10 –40°C 10 –40°C 10 –40°C
Power fuse FF 16A / 500V FF 16A / 500V FF 16A / 500V
Protection type IP 21 / EN 60529 IP 21 / EN 60529 IP 21 / EN 60529