GENLED Acolyte DiGidot CTRLPIXELTRMR Manuel utilisateur

Page 1Acolyte is a quality division of GENLED Brands™| www.AcolyteLED.com |Acolyte | Architectural Lighting Solutions
PXLNET TRANSMITTER MANUAL
CTRLPIXELTRMR
RoHS SPI DMX IP40
REV. 20SEP2023

Page 2Acolyte is a quality division of GENLED Brands™| www.AcolyteLED.com |Acolyte | Architectural Lighting Solutions Page 2Acolyte is a quality division of GENLED Brands™| www.AcolyteLED.com |Acolyte | Architectural Lighting Solutions
THANK YOU FOR CHOOSING ACOLYTE AND DIGIDOT!
Acolyte and DiGidot offer powerful products and solutions to control LED pixels.
C4 controllers are the heart of our control system, offering great exibility and simple
infrastructures. To benet from all our system advantages, we offer innovative accessories like
range extending equipment. These products allow you to send PxLNet, which is a high speed,
long-range SPI protocol. Install C4 controllers and PxLNet Transmitters in a central place for
easy access and maintenance.
Have fun creating mesmerizing lighting installations!
The Acolyte and DiGidot teams

Page 3Acolyte is a quality division of GENLED Brands™| www.AcolyteLED.com |Acolyte | Architectural Lighting Solutions
INDEX
Introduction 4
Contents 4
PxLNet Transmitter Features 4
Technical Drawings 5
Product Description 6
Technical Specications 7
Before Installation 8
Installation & Wiring 9
Mounting 10
Power Supply 11
Connecting Power 11
Wiring Schemes 12
Operation 14
Tips & Troubleshooting 15
General Information 15
Compliances 16

Page 4Acolyte is a quality division of GENLED Brands™| www.AcolyteLED.com |Acolyte | Architectural Lighting Solutions
INTRODUCTION
CONTENTS
PXLNET TRANSMITTER FEATURES
SPI protocols are sensitive to data distortion and often only work safely over up to 6.5 ft
(2 m) of cable distance. The PxLNet Transmitter is a small extension module that can be
connected to the C4 controller outputs. It converts SPI or DMX TTL signals to PxLNet to
send them across large distances. It can convert any industry standard SPI protocol that can
be output from an SPI controller. Output the same number of universes with this transmitter
as sent from the SPI controllers output port(s). This product can not only convert SPI
protocols but it also converts DMX TTL signals to standard DMX512. That means the PxLNet
Transmitter can be used to connect four differential DMX signals up to 1640 ft (500 m) away.
The onboard voltage regulator accepts voltages ranging from 12-24 VDC. Installation is easy
thanks to the RJ45 outputs, which quickly connect to our PxLNet Transceiver modules.
NOTE: We take great care with our products and have a standard of quality control, but we advise you to double-check for
missing or damaged items. In case of any missing or damaged items, please contact your supplier immediately. Never use
damaged products!
• Connects directly to C4 controller IO port
• Converts SPI and DMX TTL to PxLNet and DMX respectively
• Flexible operating voltage from 12-24 VDC
• 4 isolated RJ45 bus ports for PxLNet
• Built-in power supply for C4 controller
• Can be used with any third-party SPI controller
• One PxLNet Transmitter
• One 2 pin header, DC power terminal connector (already inserted)
• One quick start instruction card

Page 5Acolyte is a quality division of GENLED Brands™| www.AcolyteLED.com |Acolyte | Architectural Lighting Solutions
TECHNICAL DRAWINGS
0.98 in.
(25 mm)
2.56 in.
(65 mm)
2.56 in. (65 mm)
0.59 in.
(15.5 mm)
0.37 in.
(9.5 mm)

Page 6Acolyte is a quality division of GENLED Brands™| www.AcolyteLED.com |Acolyte | Architectural Lighting Solutions
PRODUCT DESCRIPTION
1. 4 PxLNet RJ45 output ports
2. Status LED power on (green)
3. Status LED transmitting data (yellow)
4. Power input (Left = DC- (GND) Right = DC+)
5. Power indicator LED (blue)
6. I/O Connector to C4 controllers
7. Mounting hole
Pin 1: Orange/White = (DMX) Data +
Pin 2: Orange = (DMX) Data -
Pin 3: --
Pin 4: --
Pin 5: --
Pin 6: --
Pin 7: Brown/White = (DMX) GND/DC -
Pin 8: Brown = (DMX) GND/DC

Page 7Acolyte is a quality division of GENLED Brands™| www.AcolyteLED.com |Acolyte | Architectural Lighting Solutions
TECHNICAL SPECIFICATIONS
Electrical
Input Voltage: 12-24 VDC
Max. power consumption: 1 W
Mechanical
Dimensions: 2.56 x 2.56 x 0.98 in. | 65 x 65 x 25 mm (L x W x H)
Net weight: 2.61oz (74gr)
Environmental
Operation Temperature (Tc): 32 to 122°F (0 to 50°C)
Max. ambient Temp. (Tamax): 104°F (40°C)
Storage temperature: -4 to 122°F (-20 to 50°C)
Max. operating relative humidity: 90% (indoor use only)
Protection
IP rating: IP40 (indoor use only)
DC input: Overvoltage protection (max. 24VDC)
Reverse polarity protection: Yes
Connectivity
Power wiring: Recommended: max. 14 AWG (2,5 mm2)
Quality
Warranty: 5-year factory warranty
Components: RU Certied
Compliances: CE, RoHS, ETL pending
Applied standards: EN60950-1:2006 +A11:2009 + A1:2010 + A12:2011 +
A2:2013, IEC60950-1 / EN60950-1, EN61006-6-3,
EN55032

Page 8Acolyte is a quality division of GENLED Brands™| www.AcolyteLED.com |Acolyte | Architectural Lighting Solutions
BEFORE INSTALLATION
Before installing our products it’s important to note the following safety and installation
instructions.
SAFETY INSTRUCTIONS
• Before installation and use of this product, read this manual carefully.
• Make sure these instructions are handed over to those responsible for installation, use
and maintenance of this product.
• Local electrical and safety rules and guidelines always overrule this manual.
• Installation should only be carried out by professional certied installers that are qualied
to work on electrical installations.
• Do not conduct any repairs of this device (there are no user serviceable parts inside).
Any unapproved repairs and/or product modications will void product warranty.
Acolyte and DiGidot Technologies B.V. cannot be held liable for any consequences.
• Repairs of this product may only be carried out by DiGidot Technologies B.V.
• Repairs and maintenance of the installation may only be carried out by qualied
technicians.
• Always disconnect the mains power when working on a high voltage electric installation.
Failure to do so may result in product damage and/or personal injury.
• Do not connect or modify this product other than described in this manual.
• Never use a product that is visibly damaged or does not work correctly. Never use a
product if it starts to smoke or if a crackling/sizzling noise is audible. If this is the case,
disconnect the power to the device and contact Acolyte immediately.
• The only way to power off this product is to disconnect it from the power source.
• The product is designed for indoor use (dry locations) only.

Page 9Acolyte is a quality division of GENLED Brands™| www.AcolyteLED.com |Acolyte | Architectural Lighting Solutions
INSTALLATION AND WIRING
WIRING
Please follow these instructions when connecting your controls system. Make sure to power
the C4 controller and PxLNet Transmitter individually. Use the supplied Power Jack cable to
power the C4 controller.
PxLNet Transmitter
12-24V DC
C4 Extended or C4 Live controller

Page 10Acolyte is a quality division of GENLED Brands™| www.AcolyteLED.com |Acolyte | Architectural Lighting Solutions
MOUNTING
Before mounting and connecting power to the PxLNet Transmitter, make sure to follow these
steps:
1. Disconnect power from the C4 controller.
2. Remove the terminal connector from the C4 controller I/O port.
3. Connect the I/O connector of the PxLNet Transmitter to the I/O port of the C4 controller in
the upright position. Be sure the connector is straight and rmly inserted.
4. Install the C4 and PxLNet Transmitter by inserting athead screws, spaced according to the
drawing below, in the mounting surface. Leave about 0.2 in. (4-5 mm) between the surface
and underside of the screw heads.
5. Position the mounting holes of both devices over the screws and slide them in place.
WARNING!
• This product should not be subjected to high temperatures (risk of fatal damage).
• Keep this product away from direct sunlight, rain or other moisture (risk of fatal damage).
• Do not use this product outdoors or in humid environments (short-circuit risk).
Table des matières
Manuels Émetteur populaires d'autres marques

Dejero
Dejero EnGo 3x Manuel utilisateur

Rosemount
Rosemount 4600 Manuel utilisateur

Speaka Professional
Speaka Professional 2342740 Manuel utilisateur

trubomat
trubomat GAB 1000 Manuel utilisateur

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Manuel utilisateur

Rondish
Rondish UT-11 Manuel utilisateur