Cray XC30-LC Manuel

XC30-LC and XC40-LC Repair Procedures
(2.0) H-8002 Rev A

Contents
1 About the XC30-LC and XC40-LC Repair Procedures...........................................................................................6
1.1 Safety Information.....................................................................................................................................7
1.2 XC30-LC and XC40-LC Spare Part Numbers.........................................................................................10
2 System Cabinet Procedures.................................................................................................................................20
2.1 Power Down a System Cabinet...............................................................................................................20
2.2 Power Up a System Cabinet...................................................................................................................20
2.3 Power Supply Replacement....................................................................................................................21
2.3.1 Remove a Power Supply............................................................................................................21
2.3.2 Install a Power Supply................................................................................................................22
2.4 Operator Interface Replacement.............................................................................................................23
2.4.1 Remove an Operator Interface...................................................................................................23
2.4.2 Install an Operator Interface.......................................................................................................25
2.5 Environmental Distribution Board Replacement......................................................................................26
2.5.1 Remove an Environmental Distribution Board...........................................................................26
2.5.2 Install an Environmental Distribution Board...............................................................................27
2.6 Liquid Sensor Replacement....................................................................................................................29
2.6.1 Remove a Liquid Sensor............................................................................................................29
2.6.2 Install a Liquid Sensor................................................................................................................30
2.7 Chassis Backplane Replacement............................................................................................................31
2.7.1 Remove a Chassis Backplane...................................................................................................31
2.7.2 Install a Chassis Backplane.......................................................................................................36
2.8 Power Distribution Unit (PDU) Replacement...........................................................................................41
2.8.1 Remove a Power Distribution Unit (PDU)..................................................................................41
2.8.2 Install a Power Distribution Unit (PDU)......................................................................................43
2.9 Power Supply Rack Replacement...........................................................................................................45
2.9.1 Remove a Power Supply Rack...................................................................................................45
2.9.2 Install a Power Supply Rack.......................................................................................................48
2.10 Cabinet Controller Replacement...........................................................................................................52
2.10.1 Remove a Cabinet Controller...................................................................................................52
2.10.2 Install a Cabinet Controller.......................................................................................................53
2.11 Cabinet Controller Backplane Replacement..........................................................................................54
2.11.1 Remove a Cabinet Controller Backplane.................................................................................54
2.11.2 Install a Cabinet Controller Backplane.....................................................................................56
2.12 Cabinet Controller DIMM Replacement.................................................................................................58
2.12.1 Remove a Cabinet Controller DIMM........................................................................................58
Contents
2

2.12.2 Install a Cabinet Controller DIMM............................................................................................59
2.13 Chassis Host Replacement...................................................................................................................61
2.13.1 Remove a Chassis Host...........................................................................................................61
2.13.2 Install a Chassis Host...............................................................................................................62
2.14 Optical Network Cable Replacement.....................................................................................................64
2.14.1 Remove an Optical Network Cable (AOC)...............................................................................64
2.14.2 Install an Optical Network Cable (AOC)...................................................................................65
2.15 Copper Network Cable Replacement....................................................................................................66
2.15.1 Remove a Copper Network Cable............................................................................................66
2.15.2 Install a Copper Network Cable................................................................................................67
2.16 Temperature and Humidity Sensor Replacement..................................................................................68
2.16.1 Remove a Temperature and Humidity Sensor.........................................................................68
2.16.2 Install a Temperature and Humidity Sensor.............................................................................70
2.17 Coil Control Board Replacement...........................................................................................................71
2.17.1 Remove a Coil Control Board...................................................................................................71
2.17.2 Install a Coil Control Board.......................................................................................................73
2.18 Non-spring Returned Water Valve Actuator Replacement....................................................................75
2.18.1 Remove a Non-Spring Returned Water Valve Actuator...........................................................75
2.18.2 Install a Non-Spring Returned Water Valve Actuator...............................................................77
2.19 Spring Returned Water Valve Actuator Replacement............................................................................80
2.19.1 Remove a Spring Returned Water Valve Actuator...................................................................80
2.19.2 Install a Spring Returned Water Valve Actuator.......................................................................82
2.20 Redesigned Water Pressure Transducer Replacement........................................................................83
2.20.1 Remove a Redesigned Water Pressure Transducer................................................................84
2.20.2 Install a Redesigned Water Pressure Transducer....................................................................85
2.21 Original Water Pressure and Temperature Transducer Replacement...................................................86
2.21.1 Remove an Original Water Pressure and Temperature Tranducer..........................................86
2.21.2 Install an Original Water Pressure and Temperature Transducer.............................................87
2.22 Return or Supply Temperature Sensor Replacement............................................................................88
2.22.1 Remove a Return or Supply Temperature Sensor...................................................................88
2.22.2 Install a Return or Supply Temperature Sensor.......................................................................89
3 Blower Cabinet Procedures..................................................................................................................................92
3.1 Blower Assembly Replacement...............................................................................................................92
3.1.1 Remove a Blower Assembly......................................................................................................92
3.1.2 Install a Blower Assembly..........................................................................................................93
3.2 Blower Control Assembly Replacement..................................................................................................94
3.2.1 Remove a Blower Control Assembly..........................................................................................94
3.2.2 Install a Blower Control Assembly..............................................................................................95
Contents
3

3.3 Blower PDU Replacement.......................................................................................................................97
3.3.1 Remove a Blower Power Distribution Unit (PDU)......................................................................97
3.3.2 Install a Blower Power Distribution Unit (PDU)..........................................................................99
4 Preconditioner Cabinet Procedures....................................................................................................................103
4.1 Preconditioner Liquid Sensor Replacement..........................................................................................103
4.1.1 Remove a Preconditioner Liquid Sensor..................................................................................103
4.1.2 Install a Preconditioner Liquid Sensor......................................................................................104
4.2 Non-Spring Returned Preconditioner Water Valve Actuator Replacement............................................106
4.2.1 Remove a Non-Spring Returned Preconditioner Water Valve Actuator...................................106
4.2.2 Install a Non-Spring Returned Preconditioner Water Valve Actuator.......................................107
4.3 Spring Returned Preconditioner Water Valve Actuator Replacement...................................................109
4.3.1 Remove a Spring Returned Preconditioner Water Valve Actuator...........................................109
4.3.2 Install a Spring Returned Preconditioner Water Valve Actuator...............................................111
4.4 Original Preconditioner Water Pressure and Temperature Transducer Replacement...........................113
4.4.1 Remove an Original Preconditioner Water Pressure and Temperature Transducer................113
4.4.2 Install an Original Preconditioner Water Pressure and Temperature Transducer....................114
4.5 Redesigned Preconditioner Water Pressure Transducer Replacement................................................115
4.5.1 Remove a Redesigned Preconditioner Water Pressure Transducer........................................115
4.5.2 Install a Redesigned Preconditioner Water Pressure Transducer............................................116
4.6 Preconditioner Return or Supply Temperature Sensor Replacement....................................................118
4.6.1 Remove a Preconditioner Return or Supply Temperature Sensor...........................................118
4.6.2 Install a Preconditioner Return or Supply Temperature Sensor...............................................119
4.7 Preconditioner Air Temperature Sensor Replacement..........................................................................121
4.7.1 Remove a Preconditioner Air Temperature Sensor..................................................................121
4.7.2 Install a Preconditioner Air Temperature Sensor......................................................................122
4.8 Preconditioner Temperature and Humidity Sensor Replacement..........................................................122
4.8.1 Remove a Preconditioner Temperature and Humidity Sensor.................................................122
4.8.2 Install a Preconditioner Temperature and Humidity Sensor.....................................................124
4.9 Preconditioner Coil Control Board Replacement...................................................................................126
4.9.1 Remove a Preconditioner Coil Control Board..........................................................................126
4.9.2 Install a Preconditioner Coil Control Board..............................................................................127
5 Compute and IO Blade Procedures....................................................................................................................129
5.1 Remove a Blade Using xtwarmswap.....................................................................................................129
5.2 Install a Blade Using xtwarmswap.........................................................................................................131
5.3 Remove a Compute or IO Blade...........................................................................................................133
5.4 Install a Compute or IO Blade...............................................................................................................134
5.5 Blade Memory DIMM Replacement.......................................................................................................135
5.5.1 Remove a Blade Memory DIMM..............................................................................................135
Contents
4

5.5.2 Install a Blade Memory DIMM..................................................................................................136
5.6 Voltage Module (VRM, VIVOC, and HIVOC) Replacement...................................................................137
5.6.1 Remove a Voltage Module (VRM, VIVOC, and HIVOC)..........................................................137
5.6.2 Install a Voltage Module (VRM, VIVOC, and HIVOC)..............................................................138
5.7 Processor Replacement........................................................................................................................139
5.7.1 Remove a Processor................................................................................................................140
5.7.2 Install a Processor....................................................................................................................142
5.8 KPDC Processor Replacement.............................................................................................................146
5.8.1 Remove a Processor on an KPDC...........................................................................................146
5.8.2 Install a Processor on a KPDC.................................................................................................149
5.9 KPDC Replacement..............................................................................................................................153
5.9.1 Remove a KPDC......................................................................................................................153
5.9.2 Install a KPDC..........................................................................................................................154
5.10 QPDC Replacement............................................................................................................................156
5.10.1 Remove a QPDC....................................................................................................................157
5.10.2 Install a QPDC........................................................................................................................158
5.11 XPDC Replacement............................................................................................................................159
5.11.1 Remove a XPDC....................................................................................................................159
5.11.2 Install an XPDC......................................................................................................................160
5.12 SGDC Replacement............................................................................................................................161
5.12.1 Remove a SGDC....................................................................................................................161
5.12.2 Install a SGDC........................................................................................................................162
5.13 GPDC Replacement............................................................................................................................163
5.13.1 Remove a GPDC....................................................................................................................163
5.13.2 Install a GPDC........................................................................................................................164
5.14 HPDC Replacement............................................................................................................................165
5.14.1 Remove a HPDC....................................................................................................................165
5.14.2 Install a HPDC........................................................................................................................166
5.15 PCI Card Replacement........................................................................................................................167
5.15.1 Remove a PCI Card...............................................................................................................167
5.15.2 Install a PCI Card...................................................................................................................169
5.16 IO Base Board (IOBB) Component Replacement...............................................................................170
5.16.1 Remove Components from an IO Base Board (IOBB)...........................................................170
5.16.2 Install Components on an IO Base Board (IOBB)..................................................................170
6 System Maintenance Workstation (SMW)..........................................................................................................172
7 Boot RAID Cabinet.............................................................................................................................................173
Contents
5

1About the XC30-LC and XC40-LC Repair Procedures
This publication describes how to remove and replace the field replaceable units (FRUs) in Cray® XC30-LC and
XC40-LC systems.
Release Information
Table 1. Record of Revision
Publication Title Publication Number Date
XC30-LC and XC40-LC Repair
Procedures
H-8002 December 2016
XC Series-LC Repair Procedures December 2015
Maintenance and Replacement
Procedures for Cray XC30 Systems
H80-8002-B January 2014
Maintenance and Replacement
Procedures for Cray XC30 Systems
H80-8002-A September 2013
Maintenance and Replacement
Procedures for Cray XC30 Systems
H80-8002 October 2012
Typographic Conventions
Monospace Indicates program code, reserved words, library functions, command-line prompts,
screen output, file/path names, key strokes (e.g., Enter and Alt-Ctrl-F), and
other software constructs.
Monospaced Bold Indicates commands that must be entered on a command line or in response to an
interactive prompt.
Oblique or Italics Indicates user-supplied values in commands or syntax definitions.
Proportional Bold Indicates a graphical user interface window or element.
\ (backslash) At the end of a command line, indicates the Linux® shell line continuation character
(lines joined by a backslash are parsed as a single line). Do not type anything after
the backslash or the continuation feature will not work correctly.
Scope and Audience
This publication is intended for Cray service personnel. Personnel must complete XC30-LC and XC40-LC
hardware training before performing these maintenance and replacement procedures.
About the XC30-LC and XC40-LC Repair Procedures
6

Torx Fasteners
The XC Series cabinet and blades contain both Torx and Torx+ fasteners. The drivers and bits in the tool kit are
Torx. Torx drivers and bits work with both Torx and Torx+ fasteners.
HSS Component Naming Conventions
This publication refers to the HSS ID of the target component as the hostname. The man pages for the various
commands refer to the target component as the hostname, physIDlist, id-list, or some other name; these
names all refer to the standard HSS ID for the target component. The procedures include an example of the HSS
ID for each command.
Feedback
Visit the Cray Publications Portal at http://pubs.cray.com and make comments online using the Contact Us button
in the upper-right corner or Email pubs@cray.com. Your comments are important to us and we will respond within
24 hours.
Trademarks
The following are trademarks of Cray Inc. and are registered in the United States and other countries: CRAY and
design, SONEXION, URIKA, and YARCDATA. The following are trademarks of Cray Inc.: APPRENTICE2,
CHAPEL, CLUSTER CONNECT, CRAYDOC, CRAYPAT, CRAYPORT, DATAWARP, ECOPHLEX, LIBSCI,
NODEKARE. The following system family marks, and associated model number marks, are trademarks of Cray
Inc.: CS, CX, XC, XE, XK, XMT, and XT. The registered trademark LINUX is used pursuant to a sublicense from
LMI, the exclusive licensee of Linus Torvalds, owner of the mark on a worldwide basis. Other trademarks used in
this document are the property of their respective owners.
1.1 Safety Information
Read and comply with the following safety information while servicing XC30-LC and XC40-LC systems.
DANGER:
● Electrocution Hazard
● Cray requires the power to be disconnected from the PDU when working on components inside the
PDU chassis. If it is necessary to work on components in the PDU with power applied, a minimum 36-
in working clearance must be maintained in front of the PDU. This workspace is required and must be
maintained around all electrical equipment where parts of an energized system may be serviced. To
maintain this clearance, remove the door from the cabinet facing the energized parts, and install an
insulating barrier to prevent any grounded equipment from coming in contact with the energized
components in the PDU. Failure to do so could result in serious injury or death.
WEEE Directive
The Waste Electrical and Electronic Equipment (WEEE) directive of the European Union (EU) is designed to
reduce waste management problems linked to heavy metals and flame retardants. It attempts to limit the amount
of electrical and electronic equipment that enters landfills by encouraging reuse, recycling, and separate
collection. Components that bear the crossed-out wheelie bin symbol require special disposal.
About the XC30-LC and XC40-LC Repair Procedures
7

In accordance with European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE), the
presence of the crossed-out wheelie bin symbol on a product or on its packaging indicates that you must not
dispose of that item in the normal unsorted municipal waste stream. Instead, it is your responsibility to dispose of
that product by returning it to a collection point that is designated for the recycling of electrical and electronic
equipment waste. Separate collection of this waste helps to optimize the recovery and recycling of any
reclaimable materials and reduces the impact on human health and the environment.
ESD Precautions
Observe electrostatic discharge (ESD) precautions during any maintenance or repair of Cray systems. Required
apparel includes an ESD smock, ESD shoes, and an ESD wrist strap. ESD and Safety Guidelines H-0016,
contains information about safety procedures and potential hazards. Read these guidelines before servicing any
Cray systems.
CAUTION:
● Equipment damage
● Observe all ESD precautions. Failure to do so can result in damage to the equipment.
ESD Smock
Wear a Cray approved static-dissipative smock while servicing or handling an ESD-sensitive device. Completely
button the smock and wear it as the outermost layer of clothing. A portion of the smock’s sleeves must be in direct
contact with the skin of the arms. Skin contact is essential for a dissipative path-to-earth ground. Tuck hair that
exceeds shoulder length inside the back of the smock.
ESD Shoes
Wear approved static-dissipative shoes or approved dissipative heel straps on both shoes while servicing or
handling an ESD-sensitive device. When sensitive equipment is exposed to static discharge, ESD shoes help
prevent an excessive charge from building up.
About the XC30-LC and XC40-LC Repair Procedures
8

Blade Handling
Each blade weighs approximately 29 lbs (13 kg). Blades can be removed or installed using a lift.
WARNING:
● Personal injury
● Use and proper lifting techniques when handling blades. Failure to do so could result in serious
personal injury.
CAUTION:
● Equipment damage
● Always observe the ESD and safety precautions described in the previous section when handling
blades. Failure to do so could result in equipment damage.
Safety Measures
Observe the following safety measures to remove, install, repair, or maintain the system.
● Do not wear watches or jewelry while working on a system cabinet.
● Keep fingers and conductive tools away from high-voltage areas and from high-current areas.
DANGER:
● Serious injury or death
● Keep fingers and conductive tools away from high-voltage areas. Serious injury or death will occur if
these precautions are not followed.
WARNING:
● Severe personal injury
● Ensure that the electrical circuit breakers for the equipment being serviced are off, locked, and
tagged. Failure to do so could result in severe shock and burns.
● Remove all tools from the system cabinets after performing service.
● Replace all covers and panels that were removed from the system during servicing.
● Some procedures require powering off the system; power off the system only after shutting down the system
software in an orderly manner.
CAUTION:
● Loss of data
● Do not power off the system before halting the operating system. Failure to do so could result in loss
of data.
Cray systems may reach noise levels where the use of hearing protection is required. The need for this protection
depends on such factors as the number of installed cabinets, the speed of the blowers, and the physical design
and the materials used in the computer room. The use of hearing protection is highly recommended for all
About the XC30-LC and XC40-LC Repair Procedures
9

personnel when working in computer rooms, even if noise exposure dosimetry results are below the USA OSHA
or other country's regulatory levels.
1.2 XC30-LC and XC40-LC Spare Part Numbers
Table 2. Tools
Part Number Description
80299500 Adjustable Torque Driver, 5-40 in-lbs.
100737101 Torque Wrench, 1/4" Drive 30-150 in-lbs.
80294700 Adaptor, 1/4in. hex male to 1/4in. square male
100784000 Balldriver Set, 11 Piece 5/64-3/8"
80263400 Dusting gas
100117500 Thermal grease
Table 3. XC Series-LC System Cabinet
Part Number Description Procedure
100790601 POWER SUPPLY, 52VDC 3KW
230-277VAC (RECTIFIER)
Install a Power Supply
100648000 INTERFACE MODULE,
OPERATOR
Install an Operator Interface on
page 25
100692802 ENVIRONMENTAL CONTROL
ASSY
Install an Environmental Distribution
Board on page 27
100673900 SENSOR ASSY, LIQUID SENSE
(INC. 100208502 WATER 4WIRE
5VDC SENSOR)
Install a Liquid Sensor on page 30
100931500 BACKPLANE ASSY AND
REPLACEMENT KIT
Install a Chassis Backplane on
page 36
100542901 PDU ASSY, COMPUTE CABINET Install a Power Distribution Unit
(PDU) on page 43
100826600 BUS BAR ASSY, POWER RACK
AND HORIZONTAL, 105KW
ELTEK/VALERE
Install a Power Supply Rack on
page 48
100697500 MODULE ASSY, CABINET
CONTROLLER CS
Install a Cabinet Controller
100727500 BACKPLANE ASSY, CABINET
CONTROLLER
Install a Cabinet Controller
Backplane
About the XC30-LC and XC40-LC Repair Procedures
10
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Cray Ordinateur de bureau

Cray
Cray XD1 Guide de démarrage rapide

Cray
Cray T3E Manuel utilisateur

Cray
Cray CRAY-1 Guide rapide de l'utilisateur

Cray
Cray XD1 Manuel utilisateur

Cray
Cray CX1000 Mode d'emploi

Cray
Cray X-MP Series Manuel utilisateur

Cray
Cray X-MP Manuel utilisateur

Cray
Cray CX1 Manuel utilisateur

Cray
Cray CX1 Guide de configuration