QUICKSTART:DS71MD4SERIES
Configuration:
1. Connect to the Serial port (EIA232) using the supplied rollover flat cable and adapter.
2. Use terminal emulation software to access the unit, (i.e. Microsoft Hyper-terminal). Set the PC
serial port configuration to the following: 9600 bps, 8 data bits, 1stop bit, no parity, and No
Flow Control.
3. If you get only a blinking cursor Press ‘Enter’. If still only a blinking cursor, Type (5)
Attention Characters, (factory default is the semi-colons {;}). The Attention Character will not
echo on the screen. There is a one second delay before the menu is displayed. You should see
a menu similar to (Figure 1).
4. Select ‘C’ for the configuration menu, (Figure 2).
5. Select ‘1’ for the DS71-MD4 module, (Figure 3).
6. Select the number for ‘Login Setup’ option, (Figure 4).
7. Select the number for ‘Manage Users’ option, (Figure 5).
8. NOTE: The ‘admin’ user can not be deleted.
9. Select ‘A’ to add a user. Type the name.
10. Select the number of the name just added and to enter their password, (Figure 6).
11. Press ‘Enter’ until get to the ‘Login Setup Menu’ (Figure 3).
12. Select ‘Assign User Ports’ and select a user, (Figure 7). Add a port or add all ports.
13. Press ‘Enter’ until get to the ‘Login Setup Menu’ (Figure 3).
14. Repeat steps 7-13 to add additional users and to assign ports.
15. Once finished adding users, Press ‘Enter’ until get to the ‘Login Setup Menu’ (Figure 3).
16. Select ‘Access Control’ to enable User and Password prompt (Figure 8).
17. At this point you have the minimum configuration to begin operations. You may wish to make
other changes to meet your needs. Press ‘Enter’ until you are at the main menu. Type “T” to
end session
18. Connect the Analog telecom phone line to the modem and test the connection. You will see
the same menus as seen in the serial port.
If this is a new unit shipped directly from Baytech, follow the steps. If this is a previously own unit,
perform a factory reset to clear out any users and passwords still in the unit.