ZK S900 Manuel utilisateur

S900
Time & Attendance and Access Control Terminal
Installation Instructions
Revised March 2008

About this Guide
This guide provides installation instructions only. For information regarding
actual operation and configuration of the S900 Time & Attendance and Access
Control Terminal, refer to the user manual.

TableofContents
Before Installation................................................................................. 1
1. System Configuration ....................................................................... 3
1.1 Illustration of system configuration........................................... 3
1.2 Communication Options............................................................ 4
2. Installation ......................................................................................... 5
2.1 S900 Wall Mounting.................................................................. 5
2.2 Connecting Peripheral Equipment............................................. 6
2.2.1 Door sensor connection .................................................. 8
2.2.2 Exit-button connection ................................................... 9
2.2.3 Alarm connection ........................................................... 9
2.2.4 Door lock connection ................................................... 11
2.2.5 Ethernet connection...................................................... 15
2.2.6 RS232 connection......................................................... 17
2.2.7 RS485 connection......................................................... 18
2.2.8 Wiegand output connection .......................................... 19
2.2.9 Connecting with external Weigand reader.................... 20
2.2.10 Power connection ....................................................... 21
3. Miscellaneous Features................................................................... 22
3.1 Reset........................................................................................ 22
3.2 Tamper-proof Button ............................................................... 23
3.3 Using USB flash drive............................................................. 23
3.4 Built-in proximity card reader (Optional) ............................... 23
3.5 Built-in MIFARE card reader (Optioonal) .............................. 23
3.6 Built-in HID card reader (Optional) ........................................ 24
3.7 Built-in WiFi (Optional).......................................................... 24
4. Troubleshooting............................................................................... 25
4. Appendix – WiFi configuration………………………………….. 27

Before Installation
Read all instructions prior to installation.
1. Prior to beginning installation, cut off all power to prevent personal
injury and damage to S900 and peripheral equipment.
2. Connect the ground wire first, in order to prevent electro-static damage
to the S900.
3. Connect power supply to the S900 last. If the S900 does not operate
properly, always cut off power to it before examining/dismantling. Be
advised that wiring the S900 while power is on may cause damage to the
device. Possible resulting damage from not powering off the S900
prior to wiring is not covered by manufacturer’s warranty.
4. Mount the S900 at a comfortable height, typically between 4 and 5 feet from
the ground.
5. After installation, remove protective film from the S900 display and
fingerprint sensor.
6. To prevent being accidentally locked out while testing the exit-door
button, keep a person on the inside of the door.
7. Run the auto-test function to confirm that installation is successful.
8. In order to maximize the life of the S900, use the auto-sleep and wake up
functions.
9. We recommend using a 12V DC 1.5Amp power supply for proper
functioning of the S900 terminal. If the incorrect voltage is used, the
S900 may keep rebooting or may not operate the electric door lock (if
attached).
-1-

10. Improper wiring may cause the S900’s main circuit board and fingerprint
sensor to burn out. Resulting damage from
improper wiring is not covered under manufacturer’s warranty.
11. Only use supplied transformer and cord. Do not attempt extending the
cord by cutting and splicing.
12. If using RS485 mode of communication, use only a ZK
Software-supplied RS485 converters. Using a 3rd party RS485
converter may or may not work. If the RS485 cable length exceeds 200
feet, we recommend using a 120Ώterminator.
13. Refer to the user handbook and operating instructions for further
information.
-2-

- 3 -
1. System Configuration
1.1Illustration of system configuration

- 4 -
1.2 Communication Options
The S900 can directly connect with a PC through RS232 or Ethernet:
The S900 can connect with a PC through RS485 network:
The S900 can connect with a PC through Ethernet network:

- 5 -
2.Installation
2.1 S900 Wall Mounting
1. Separate mounting plate from the S900 by removing the screw at
the bottom edge of the S900. Special screwdriver is supplied.
2. Determine the position of the mounting plate on the wall. The S900
should be mounted on the external wall of the door approximately 4
to 5 feet from the ground. After the desired position is determined,
cut out an opening (approximately 1 ½ inch x 1 ½ inch) for cables
(see below figure’s shadowed area).
3. Line up the opening of the mounting plate with the newly cut-out
opening on the wall, and then screw the plate to the wall.
4. After installation, make sure the mounting plate is tightly secured to
the wall.
Figure1

- 6 -
2.2 Connecting peripheral equipment
Caution: Cut off surrounding power before connecting peripheral
equipment
Follow instructions to connect peripheral equipment, such as:
Door sensor connection
Exit-button connection
Alarm connection
Door lock connection
Ethernet connection
RS232 connection
RS485 connection
Wiegand output connection
Power connection

- 7 -
Table 1: Definition of S900 Terminal Pin Layout
J 7, 9pin connector
1st NC2 Connect to Alarm NC terminal
2nd COM2 Connect to Alarm COM terminal
3rd NO2 Connect to Alarm NO terminal
4th NC1 Connect to Lock NC terminal
5th COM1 Connect to Lock COM terminal
6th NO1 Connect to Lock NO terminal
7th Button Connect to Release button
8th GND For Door sensor and release button
9th Sensor Connect to Door sensor
J1, 2Pin connector
1st GND Connect to Power GND
2nd +12V Connect to Power +12v
J2, 4Pin connector
1st RJ45-6 Connect to RJ45 plug wiring 6
2nd RJ45-3 Connect to RJ45 plug wiring 3
3rd RJ45-2 Connect to RJ45 plug wiring 2
4th RJ45-1 Connect to RJ45 plug wiring 1
Table des matières
Manuels Terminal tactile populaires d'autres marques

Wincor Nixdorf
Wincor Nixdorf iPOS plus Advanced Manuel utilisateur

Ingenico
Ingenico AXIUM EX4000 Manuel utilisateur

Heisei Electronics
Heisei Electronics Q-POS 815 Manuel utilisateur

Amano
Amano MTX-15 Manuel utilisateur

FLOWBIRD
FLOWBIRD CWT Compact Touch Manuel utilisateur

Demco
Demco SP7 Manuel utilisateur