WNC UMC-ZBCARD Manuel utilisateur

Subject: UMC-ZBCARD User Manual REV: 5.0
PAGE 1 OF 14
Wistron Neweb Corporation Proprietary & Confidential
Design Document
UMC-ZBCARD User Manual

Subject: UMC-ZBCARD User Manual REV: 5.0
PAGE 2 OF 14
Wistron Neweb Corporation Proprietary & Confidential
Design Document
Revision History
Issue Date
Version
Description
2018/11/14
1.0
Initial Issued
2018/11/29
2.0
Initial Issued
2018/11/29
3.0
Add Warring message
2018/12/17
4.0
Add part 15 FCC rule
2018/12/19
5.0
Modify part 15C information

Subject: UMC-ZBCARD User Manual REV: 5.0
PAGE 3 OF 14
Wistron Neweb Corporation Proprietary & Confidential
Design Document
Contents
1. Introduction............................................................................................................................................ 4
2. Test Setup Configuration ....................................................................................................................... 5
2.1 Power Supply and Debug Console Connection......................................................................... 6
i. UMC-ZBCARD..................................................................................................................... 6
ii. UMC-A21LG2-R................................................................................................................... 7
iii. Interface board ....................................................................................................................... 8
iv. Connection between UMC-ZBCARD, UMC-A21LG2-R and interface board..................... 9
2.2 Zigbee Connection....................................................................................................................11
2.3 Hardware Component Introduction ......................................................................................... 12
2.4 Install Qualcomm USB driver ................................................................................................ 13
2.5 Confirm the Qualcomm device .............................................................................................. 13
3. Zigbee test ........................................................................................................................................... 15
3.1 Firmware version of Application .......................................................................................... 15
3.2 ZigBee Test Command............................................................................................................ 16
4. Interfaces.............................................................................................................................................. 17
4.1 Qualcomm HS-USB MDM Diagnostics 90B2 (COM port).................................................... 17
4.2 Qualcomm HS-USB WWAN Adapter 90B2........................................................................... 18
4.3 Qualcomm HS-USB Modem 90B2 ......................................................................................... 18
5. Appendix I ........................................................................................................................................... 20

Subject: UMC-ZBCARD User Manual REV: 5.0
PAGE 4 OF 14
Wistron Neweb Corporation Proprietary & Confidential
Design Document
1. Introduction
This User Manual of UMC-ZBCARD is to describe how to use the following sections
for lab test by specific qualified engineers or technicians. Furthermore, this SMCC (Smart
Metering Communication Card) is NOT intended for commercial use but designed as part
of Smart Meter product which mainly provides 4G LTE WAN access. The UMC-ZBCARD
is optional for SMCC. For the procedure of SMCC installation and set-up for testing and
operating, the information is described as well in the following description.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
For Class B digital device or peripheral or cordless phone (15.105) This equipment has been
tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference toradio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
◆Reorient or relocate the receiving antenna.
◆Increase the separation between the equipment and receiver.
◆Connect the equipment into an outlet on a circuit different from that to which the
receiver is needed.
◆Consult the dealer or an experienced radio/TV technician for help.

Subject: UMC-ZBCARD User Manual REV: 5.0
PAGE 5 OF 14
Wistron Neweb Corporation Proprietary & Confidential
Design Document
-This is module approval and thus OEM integrator statement and contained ID must be
provided.
This device is intended only for OEM integrators under the following conditions:
1) For Meter installations (the end device install with ZB card), the antenna must be
installed such that 20 cm is maintained between the antenna and users.
2) The transmitter module may not be co-located with any other transmitter or antenna. As
long as the 2 conditions above are met, further transmitter testing will not be
required. However, the OEM integrator is still responsible for testing their end-product for
any additional compliance requirements required with this module installed (for example,
add more device interface etc.).
IMPORTANT NOTE: In the event that these conditions cannot be met (for example
certain meter configurations or co-location with another transmitter), then the FCC
authorization is no longer considered valid and the FCC ID cannot be used on the final
product. In these circumstances, the OEM integrator will be responsible for re-evaluating
the end product (including the transmitter) and obtaining a separate FCC authorization.
End Product labeling this transmitter module is authorized only for use in devices
where the antenna may be installed such that 20 cm may be maintained between the antenna
and users (For meter device.. The final end product must be labeled in a visible area with
the following: "Contains TX FCC ID: {NKR-LMZBCARD}".
The ZigBee antenna type is PIFA. ZigBee Antenna Peak Gain is 0.64 ~ 1.02 dBi
Warning:
Radiation Exposure Statement
This module complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This module should be installed and operated with minimum distance of
20cm between radiator and human body.
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the device.

Subject: UMC-ZBCARD User Manual REV: 5.0
PAGE 6 OF 14
Wistron Neweb Corporation Proprietary & Confidential
Design Document
2.Test Setup Configuration
2.1 Power Supply and Debug Console Connection
i. UMC-ZBCARD
Top view
Bottom view
Zigbee antenna
Zigbee RF connector
Board to board connector

Subject: UMC-ZBCARD User Manual REV: 5.0
PAGE 7 OF 14
Wistron Neweb Corporation Proprietary & Confidential
Design Document
ii. UMC-A21LG2-R
Top view
Bottom view
Make sure to connect the Zigbee card
Debug USB port
UMC-ZBCARD connector
LTE module

Subject: UMC-ZBCARD User Manual REV: 5.0
PAGE 8 OF 14
Wistron Neweb Corporation Proprietary & Confidential
Design Document
iii. Interface board
Make sure the jumpers are in right position.

Subject: UMC-ZBCARD User Manual REV: 5.0
PAGE 9 OF 14
Wistron Neweb Corporation Proprietary & Confidential
Design Document
iv. Connection between UMC-ZBCARD, UMC-A21LG2-R and interface
board
10 pin Connect to interface board
Don’t care last 2 pin
UMC-A21LG2-R
OFF ON
UMC-ZBCARD

Subject: UMC-ZBCARD User Manual REV: 5.0
PAGE 10 OF 14
Wistron Neweb Corporation Proprietary & Confidential
Design Document
AC-DC 5V Adaptor
Interface Board
UMC-A21LG2 with UMC-ZBCARD
USB Debug Port Console
Power switch
10 pin Connect to interface board
Don’t care last 2 pin
Table des matières
Manuels Matériel informatique populaires d'autres marques

EMC2
EMC2 VNX Series Manuel du propriétaire

Panasonic
Panasonic DV0PM20105 Manuel utilisateur

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 Manuel utilisateur

Gigabyte
Gigabyte B660M DS3H AX DDR4 Manuel utilisateur

Raidon
Raidon iT2300 Manuel utilisateur

National Instruments
National Instruments PXI-8186 Manuel utilisateur