Wenger Select Lab Fixed Height Workstation Manuel utilisateur

Assembly Instructions
Select Lab Fixed Height
Workstation
Visit the Music Lab Workstations web page at www.wengercorp.com.
Contents
Important User Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Required Tools. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Hardware Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Workstation Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Optional Rackmount Shelf Assembly . . . . . . . . . . . . . . . . . . . . . . 18
Note: Please read and understand these instructions before starting the assembly.
Note: If you need additional information, contact Wenger Corporation using the information below.
©Wenger Corporation 2018 Printed in USA 2018-07 Part #225D099-02
Wenger Corporation, 555 Park Drive, P.O. Box 448, Owatonna, Minnesota 55060-0448
Questions? Call.....USA: (800) 4WENGER (493-6437) • Worldwide: +1-507-455-4100 • wengercorp.com

2
Important User Information
General
Copyright © 2018 by Wenger Corporation
All rights reserved. No part of the contents of this manual may be reproduced, copied, or transmitted in any form
or by any means including graphic, electronic, or mechanical methods or photocopying, recording, or information
storage and retrieval systems without the written permission of the publisher, unless it is for the purchaser’s
personal use.
Printed and bound in the United States of America.
The information in this manual is subject to change without notice and does not represent a commitment on the
part of Wenger Corporation. Wenger Corporation does not assume any responsibility for any errors that may
appear in these instructions.
In no event will Wenger Corporation be liable for technical or editorial omissions made herein, nor for direct,
indirect, special, incidental, or consequential damages resulting from the use or defect of these instructions.
The manufacturer reserves the right to change this product at any time.
The information in this document is not intended to cover all possible conditions and situations that might occur.
The end user must exercise caution and common sense when assembling or installing Wenger Corporation
products. If any questions or problems arise, call the Wenger Corporation at (800) 4WENGER (493-6437)
or +1-507-455-4100 worldwide.
Manufacturer
The Select Lab Fixed Height Workstation is manufactured by:
Wenger Corporation
555 Park Drive
Owatonna, MN 55060
(800) 4WENGER (493-6437) • +1 (507) 455-4100
wengercorp.com
Intended Use
· This product is intended for indoor use in normal ambient temperature and humidity conditions —
it must not be exposed to prolonged outside weather conditions.
· This product is intended to be assembled and used only as described in these instructions.
Warranty
This product is guaranteed free of defects in materials and workmanship for ten full years from date
of shipment. A full warranty statement is available upon request.
Optional power strips, digital locks and other electronic equipment are covered by the
individual manufacturer’s warranty.

3
Required Tools
· Phillips Head Screwdriver
· Rubber or Plastic Mallet
· 3/8” Open-End Wrench or Socket
· Drill
· Side Cutter or Scissors
· 3/16” Allen Wrench (supplied)
· 5/32” Hex Insert Bit (supplied)
· 1-3/4” Caster Wrench (supplied)
Safety Precautions
Make sure anyone
assembling the Select
Lab Workstation has read
and understands these
instructions.
!CAUTION
Failure to comply with
Warnings and Cautions in
this document can result
in damage to property or
serious injury.
Throughoutthismanualyoumayndcautionsandwarningswhicharedenedasfollows:
• WARNING means that failure to follow the instruction may result in serious injury or death.
• CAUTION means that failure to follow the instruction may result in serious injury or damage
to property.
Read all of these safety instructions before assembling the Select Lab Fixed Height Workstation.
!CAUTION
To avoid damage and injury,
more than one person is
needed for assembly.
!CAUTION

4
Hardware Parts List
250A508._
7 x 50mm
Particle Board Screw
(color matched paint)
1
X003583
2-3/8” Grommet
X003706
2” 5-Knuckle
Hinge
X000045
#8 x 5/8”
Pan Head Screw
X002540
8 x 25mm
Wood Dowel
5
2
3
4
100A444
Corner
Bracket
6
X003074
Flush Mount
Handle
X000824
#8-18 x 3/8”
Sheet Metal Screw
X003600
Wiring Clamp
X001503
#10-16 x 3/4”
Sheet Metal Screw
7
8
9
10
X002971
1/4-20 x 1/2”
Carriage Bolt
11
X003110
1/4-20
Wing Nut
X001442
1/4 x 47/64”
Flat Washer
X001484
1-1/2” Plug
100A534
1-3/4” Caster Wrench
12 13
14 15
X000482
#8 x 5/8
Sheet Metal Screw
16
X003730
1/4-20 x 1.97
Machine Screw
225D234
Door Stop
Bracket
X003456
Push-In
Bumper
X003741
1/4-20
Cap Nut
17
18
19 20
X003738
#6 x 3/4”
Flat Head Screw
21
X001948
3/16”
Allen Wrench
X001962
5/32” Hex
Insert Bit
X003751
8-32
Hex Nut
X002998
4” Nylon Tie
22 23
24
25
X003743
1/4-20 x 0.708”
Machine Screw
26
250A508
7 x 50mm
Particle Board Screw
(black paint)
27
*Quantities may vary, extras can be discarded.

5
Workstation Components
Item Description Item Description
28 Shelf Wiring Panel 36 Swivel Caster with Brake
29 Front Wiring Panel 37 Standard Swivel Caster
30 Back Panel 38 Adjustable Keyboard Bracket
31 Left Side Panel 39 Bottom Fixed Shelf
32 Right Side Panel 40 Wiring Access Door
33 Desktop 41 Stiener
34 Left Side Fixed Tube 42 Pullout Panel
35 Right Side Fixed Tube 43 Headphone Mount
30
32
34
31
33
35
37
39
36
38
40
42
28 29
41
43

6
Assembly
1. Connect the Shelf Wiring Panel (28) and Front Wiring Panel (29)
together using six Wood Dowels (5) and
veBlack 7 x 50 mm Particle Board Screws (27).
2. Attach the shelf Wiring Panel (30) to the Back Panel using
veWoodDowels(5)andfour7x50mmParticleBoardScrews(1).
Shelf Wiring
Panel
(28)
Back Panel
(30)
Front Wiring
Panel
(29)
Wood Dowel
(5)
Black 7 x 50mm
Particle Board Screw
(27)
Wood Dowel
(5)
7 x 50mm
Particle Board Screw
(1)

7
Assembly (continued)
3. Attach four Wiring Clamps (9) to the Back Panel using four
#10-16 x 3/4” Sheet Metal Screws (10).
4. Attach two sets of 5-Knuckle Hinges (3) to the Back Panel using two #6 x 3/4” Flat Head Screws (21).
Only one set of hinges will be attached if an optional Rackmount Shelf Accessory
will be installed.
Be sure that the screws are seated ush with the hinges.
Wiring Clamp
(9)
#10-16 x 3/4”
Sheet Metal Screw
(10)
This set of hinges will not be attached
if a Rackmount Accessory will be
installed.
5-Knuckle
Hinge
(3)
#6 x 3/4”
Flat Head Screw
(20)

8
Assembly (continued)
5. With the top facing up (the side without dowel holes), attach two sets of
Door Stop Brackets (18) to the back side of the Desktop (33) using
two #8 x 5/8” Sheet Metal Screws (17) in each.
Only one set of brackets will be attached if an optional
Rackmount Shelf Accessory will be installed.
6. Push/pull a Push-In Bumper (19) into each
Door Stop Bracket.
Use two Bumpers where there will be
adjoining Wiring Access Doors
Trimotheexcesstailsusing
a side cutter or scissors.
7. Attach the Front Wiring Panel and Back Panel Assembly to the Right Side Panel (32)
usingthreeWoodDowels(5)andve7x50mmParticleBoardScrews(1).
Leave the Particle Board Screws loose until after Step #8.
Right Side
Panel
(32)
Wood Dowel
(5)
7 x 50mm
Particle Board Screw
(1)
Door Stop
Bracket
(18)
Push-In Bumper
(19)
#8 x 5/8”
Sheet Metal
Screw
(17)
Desktop
(33)
This set of brackets will not be
attached if a Rackmount Accessory will
be installed.
Dowel holes face down.
These two screws may need to
be removed to complete Step #8.

9
Assembly (continued)
8. Use more than one person to attach the Desktop to the Front Wiring Panel and
Right Side Panel using seven Wood Dowels (5) and
three 7 x 50mm Particle Board Screws (1).
9. Tighten the Particle Board Screws installed in Step #7.
Desktop
Wood Dowel
(5)
7 x 50mm
Particle Board Screw
(1)
Tighten the
Particle Board
Screws
To avoid damage and injury,
more than one person is
needed for assembly.
!CAUTION

10
Assembly (continued)
10. Attach the Left Side Panel (31) to the Desktop, Back Panel and Front Wiring Panel
using six Wood Dowels (5) and eight 7 x 50 mm Particle Board Screws (1).
11. Attach six Wiring Clamps (9) to the Back Panel using
six #10-16 x 3/4” Sheet Metal Screws (10).
Left Side
Panel
(31)
Wood Dowel
(5)
7 x 50mm
Particle Board Screw
(1)
#10-16 x 3/4”
Sheet Metal Screw
(10)
Wiring
Clamp
(9)
Table des matières