weintek CMT G04 Series Manuel utilisateur

User Manual V1.0.0

Table of Contents
Overview........................................................................................................................................ 1Chapter1.
1.1. Specification....................................................................................................................................... 1
1.2. Dimensions......................................................................................................................................... 2
1.3. Restoring factory default ................................................................................................................... 3
1.4. LED indicator ...................................................................................................................................... 3
1.5. Battery................................................................................................................................................ 3
1.6. Power connection .............................................................................................................................. 3
cMT-G04 System Setting................................................................................................................ 4Chapter2.
2.1. Search for cMT-G04’s IP address ....................................................................................................... 4
2.2. Set in internet browser ...................................................................................................................... 4
2.3. System Setting.................................................................................................................................... 5
2.3.1. Network ......................................................................................................................................... 5
2.3.2. Date/Time...................................................................................................................................... 6
2.3.3. HMI Name...................................................................................................................................... 6
2.3.4. History............................................................................................................................................ 7
2.3.5. Email .............................................................................................................................................. 7
2.3.6. Project Management ..................................................................................................................... 8
2.3.7. System Password ........................................................................................................................... 8
2.3.8. Enhanced Security ......................................................................................................................... 9
2.3.9. EasyAccess 2.0 ............................................................................................................................... 9
2.3.10. OPA UA ........................................................................................................................................ 10
2.3.11. Communication ........................................................................................................................... 10
Updating Web Package and OS ................................................................................................... 12Chapter3.
3.1 Updating Web Package .................................................................................................................... 12
3.2 Updating OS ..................................................................................................................................... 13
How to create a cMT-G04 project ............................................................................................... 14Chapter4.
4.1. Create a new project........................................................................................................................ 14
4.2. Download project to cMT-G04......................................................................................................... 16
4.3. Monitoring OPC UA Client................................................................................................................ 17
4.4. On-line/Off-line Simulation.............................................................................................................. 17
Functions supported by cMT-G04 ............................................................................................... 19Chapter5.
OPC UA Web Management Interface.......................................................................................... 20Chapter6.
6.1. Introduction ..................................................................................................................................... 20
6.2. Startup / Shut Down ........................................................................................................................ 21
6.3. Server Settings ................................................................................................................................. 21
6.4. Edit Node.......................................................................................................................................... 23
6.5. Certificates ....................................................................................................................................... 24

cMT-G04 UserManual
V1.0.0
1
6.6. Discovery.......................................................................................................................................... 25
6.7. Advanced.......................................................................................................................................... 26

cMT-G04 UserManual
V1.0.0
1
OverviewChapter1.
1.1. Specification
IIoT Gateway with Serial Bridge
Features
With built-in Ethernet switch, SW1 and SW2 can connect
to machine network without the need for adding an
Ethernet switch, which can save wiring cost. The LAN port
connects to company/factory network.
Supports OPC UA and MQTT
Compact Design and DIN-rail Mountable
Fan-less Cooling System
Built-in 256 MB Flash Memory
Built-in Power Isolator
Wide input voltage range: 10.5~28VDC
Memory
Flash
256 MB
RAM
256 MB
Processor
ARM RISC 528MHz
I/O Port
SD Card Slot
N/A
USB Host
N/A
USB Client
N/A
Ethernet
10/100 Base-T x 1
SW1, SW2:10/100 Base-T x1 (2 port Ethernet switch)
RTC
Built-in
Power
Input Power
10.5~28VDC
Power Isolation
Built-in
Power Consumption
270mA@12VDC;150mA@24VDC
Voltage Resistance
500VAC (1 min.)
Isolation Resistance
Exceed 50Mat 500VDC
Vibration Endurance
10 to 25Hz (X, Y, Z direction 2G 30 minutes)
Specification
PCB Coating
Yes
Enclosure
Plastic
Dimensions WxHxD
109 x 81 x 27 mm
Weight
Approx. 0.14 kg
Mount
35 mm DIN rail mounting
Environment
Protection Structure
IP20
Storage Temperature
-20°~ 60°C (-4°~ 140°F)
Operating Temperature
0°~ 50°C (32°~ 122°F)
Relative Humidity
10% ~ 90% (non-condensing)
Certificate
CE
CE marked
UL
Software
EasyBuilder Pro V6.01.02 or later versions

cMT-G04 UserManual
V1.0.0
2
1.2. Dimensions
a
SW1 Ethernet Port (10M/100M)
b
SW2 Ethernet Port (10M/100M)
c
LAN Ethernet Port (10M/100M)
d
Power Connector
e
Default Button
英文版 簡中版 日文版
正面図 側面図
上面図 下面図
27mm [1.06"]
109mm [4.29"]
81mm [3.19"]
a
d
e
Front View Side View
Top View Bottom View
109mm [4.29"]
81mm [3.19"]
109mm [4.29"]
81mm [3.19"]
b
c
e e
a
d
b
c
a
d
b
c
27mm [1.06"] 27mm [1.06"]

cMT-G04 UserManual
V1.0.0
3
1.3. Restoring factory default
Press and hold on the Default button on the unit for more than 15 seconds to restore factory
default.
SW1/SW2: 192.168.100.1
LAN: DHCP
Please note that the projects and data stored in the unit are all cleared after pressing the Default
button.
1.4. LED indicator
LED indicators show the status of IIoT Gateway.
Icon
Color
Meaning
Blue
LAN Communication Status
Orange
Helps the operator to find the cMT-G04. Triggering system register LB-11959
can turn this indicator on/off.
1.5. Battery
IIoT Gateway requires a CR1220 3V lithium battery to keep the RTC running.
1.6. Power connection
Power: The unit can be powered by DC power only, the voltage range is compatible with most
controller DC systems. The power conditioning circuitry inside the unit is accomplished by a
switching power supply. The peak starting current can be as high as 500mA.
voltage range: 10.5~28 VDC
Note: Connect positive DC line to the '+' terminal and the DC ground to the '-' terminal.

cMT-G04 UserManual
V1.0.0
4
cMT-G04 System SettingChapter2.
Connect cMT-G04 via Ethernet cable, and then configure system settings by the following ways.
2.1. Search for cMT-G04’s IP address
Launch UtilityManagerEX. On the top-left menu select cMT Series - Gateway, and then select a
function from Reboot, Download, or Upload. cMT-G04 can be found in the IP/HMI Name group box
by using the model’s IP address, even if the PC or laptop is not on the same network.
UtilityManagerEX can find and change cMT-G04’s IP address. The following settings can be carried
out after obtaining the IP address.
2.2. Set in internet browser
Open internet browser (IE, Chrome, Firefox, Safari), and enter cMT-G04’s IP address to configure
cMT-G04.
The default IP: LAN: DHCP
cMT-G04 system information is shown in the Login page, and the language used can be changed in

cMT-G04 UserManual
V1.0.0
5
this page.
Icon
Description
Displays HMI name.
Displays system date.
Displays system time.
2.3. System Setting
The following part introduces cMT-G04 system settings.
Three levels of privileges can be found:
[System Setting]: Controls all the settings
[Update]: Controls limited items.
[History]: Downloads history data (Recipes and Event Logs).
2.3.1. Network
Configure Ethernet ports (LAN, SW1, SW2): IP, Mask, Gateway, and DNS.
The LAN port is set to DHCP by default. SW1 and SW2 share one IP address and by default the IP
address is 192.168.100.1.

cMT-G04 UserManual
V1.0.0
6
2.3.2. Date/Time
Set RTC date and time. Select [Sync. with host] and then click [Save] to synchronize cMT-G04 time
with the computer time.
2.3.3. HMI Name
Enter a name to identify the unit.
[Identification light]: The LED indicator of the unit will flash three times when this button is
clicked, helping user to find the unit.

cMT-G04 UserManual
V1.0.0
7
2.3.4. History
This tab offers settings related to historical data.
[Clear]: Clears history data.
[Backup]: Downloads history data in the unit to this computer.
2.3.5. Email
This tab offers settings related to email.
[SMTP]: Configure email server and relevant settings.
[Contacts]: Set email contacts in this tab.
[Update Email Contacts]: Import the email contacts built using Administrator Tools.
Table des matières
Autres manuels weintek Porte

weintek
weintek cMT-SVR-100 Manuel utilisateur

weintek
weintek cMT Series Manuel utilisateur

weintek
weintek cMT-G01 series Fiche technique

weintek
weintek cMT-G01 series Manuel utilisateur

weintek
weintek CMT G03 Series Manuel utilisateur

weintek
weintek cMT-G01 series Manuel utilisateur

weintek
weintek cMT-SVRiV5EA20 Manuel utilisateur
Manuels Porte populaires d'autres marques

LST
LST M500RFE-AS Manuel utilisateur

Kinnex
Kinnex Media Gateway Manuel utilisateur

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuel utilisateur

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuel utilisateur

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuel utilisateur

Telsey
Telsey CPVA 500 - SIP Manuel utilisateur