Vaultek PROMXI Manuel utilisateur



Toggle LCD Brightness 19
Toggle Bluetooth® 20
Toggle Smart Key Modes 20
Toggle DMT Sensitivity 20
Toggle Dual Entry Mode 20
Vaultek™ App Features / App Pairing 21 / 22
Securing Your Safe 23
Modular Interior 23
Adjust Interior Shelf Height 23
Product Registration 24
FAQ 25 / 26
Troubleshooting 27
Customer Support / Warranty 28
Table of Contents
Product Overview 01 / 04
Introduction / Warnings 05 / 06
Battery Operation / Battery Maintenance 07 / 09
Battery Installation 07
Charging the Battery 08
Master Code Programming 10
Smart Align Biometric Programming 11 / 14
Helpful Programming TIPS 11
Programming 1st and 2nd Fingerprints 12
Programming Additional Fingerprints 3-20 13
Deleting Fingerprints 14
Smart Key Operation / Smart Key Warnings 15 / 18
Smart Key Pairing 15
Toggle Smart Key Access Modes 16
To Unpair Smart Key 16
Multiple Safe Management 17
Hot Keys 18 / 20
Tamper Detection 18
Toggle Stealth Mode 18
Toggle Travel Mode 19
View Battery Status 19
Delete Fingerprints 19
Toggle Interior Light 19
Box Contents
Vaultek™ MXi Safe
Smart Key and Battery
Rechargeable Battery
AC Power Adapter and Charging Cable
Tutorial Videos
Listed below are some of the various tutorials available at vaulteksafe.com under Support/Tutorials.
Programming and Setup
Twin Pistol Rack
Hardware Mounting Kit
Owner's Manual / Quick Start Guide
Backup Keys (2)
+ More videos online.

06. Safe Status
07. Safe Name
08. Battery Level
04. Numeric Keypad
05. Micro-USB Charging Port
01. Smart Align Biometric Scanner
02. Silicone Key Hole Cover
03. LCD Screen
09. Bluetooth®
10. Smart Key
11. Impact Detection
12. Sound
13. Interior LED
LCD Screen Format
05
07
06
09 10 11 12 13
08

14. Adjustable Shelf 16. PROGRAM Button
17. Pre-Drilled Mounting Holes
15. Module System
(Twin Pistol Rack)
18. LED Light Button
19. Battery Compartment
1816
14
15
17
19

Smart Align Biometric Scanner: Personalized access for up to 20 unique ngerprints. See pages 11 to 14 for
more information.
Keypad: The numeric keypad responds quickly for rapid access and has a built-in proximity sensor that lights up
when your hand brushes against the safe. See page 10 for more information.
The Vaultek™ MXi is a biometric, PIN access / Bluetooth® access safe. Its solid structure and penetration
resistant design makes it ideal for storing valuables such as rearms, jewelry, cash, and other personal items.
Powered by a rechargeable lithium-ion battery, the safe combines high security with complete access control.
Smart Key: Remote for on demand access. See page 15 and 18 for more information.
Vaultek™ App: Open the safe with the Bluetooth app. See pages 21 and 22 for more information.
DMT (Impact Detection): Motion activated alarm can be disabled or enabled with three levels of
sensitivity (Low, Medium, and High) using the Vaultek™ app or hot key functions. See page 20 for information.
IMPORTANT Check page 18 for Smart Key warnings.
CONSEQUENTIAL, ARISING OUT OF THE USE OF, OR THE INABILITY TO USE THE VAULTEK™ SAFE.
The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of
such marks by Vaultek Safe, Inc. is under license.

Battery Operation
Your safe uses a 3.7V 18650 rechargeable lithium-ion with a at
top. A minimum 2000 mAh capacity is required, however 2200
mAh or higher can be used to increase operation time.
Battery Installation
To get started, insert one of your backup keys into the keyhole at
the top of the safe (see Figure A). Push key in and rotate the key
90 degrees clockwise to open the safe.
Locate the battery compartment inside the safe beneath the
control panel (see Figure B).
Remove the battery cover by pressing down on the tab near the
top of the cover.
Insert the 18650 rechargeable lithium-ion battery (included in
accessory box) into the battery compartment. Note that your
Vaultek™ safe automatically detects the polarity of the battery
and can be installed in either direction.
When the battery is inserted you will hear a short welcome tone
and the keypad will light up.
Once you hear the tone replace the battery cover. You are now
ready to program your safe.
Charging the Battery
Your Vaultek™ safe is powered by a rechargeable
lithium-ion battery and comes with a charging kit
which includes an AC power adapter and a micro-USB
cable. Safe and micro-USB cable can be used with all
international power adapters.
Under normal usage, a fully charged battery can last
2 months. To recharge the safe, plug the micro-USB
cable into the micro-USB receiving jack located on the
lower right side of the safe (Figure C) and connect to
a standard USB port or wall outlet using the AC power
adapter. Approximate recharge time is 2.5 hours.
When charging the LED light above the micro-USB jack
(Figure C) will be on.
Due to the powerful features within the MX Series it is
recommended to keep the safe plugged in. A specially
designed VT powerpack is available as a separate
accessory to extend operation time 4 to 5 months.
Continue on next page for more information about the battery.

Battery Maintenance
Testing the Battery Power
To check the battery level, press and hold '6' and '8' key together on the keypad for 3 seconds.
Master Code Programming
First time users should change the default code as soon as possible to prevent unauthorized access to your safe.
You will also use this master code to pair the Vaultek™ app on your smartphone, so it should be kept
condential.
TIP: Code Requirements
Enter default code 1-2-3-4 on the keypad to open your safe.
With the safe open, press and hold the '1' key then the
"PROGRAM" button together (3 seconds)(Figure D) until all
status bar LEDs turn RED and let go.
Enter your NEW master code.
Press and hold the '1' key then the "PROGRAM" button together
again (3 seconds) until all status bar LEDs turn RED and let go.
Enter your NEW master code a second time.
Press and hold the '1' key then the "PROGRAM" button together a third time (3 seconds) until the safe beeps and
all status bar LEDs turn GREEN and let go. This tone conrms that the password has been reset.
If you make a mistake and the new code will not work, simply start over with step 2.
Your code can be a minimum of 4 and a maximum
of 8 digits. We recommend a code 6 to 8 digits in
length using at least one of each key to make it more
dicult for someone to guess your code. For your
security, the safe will time out and sleep if 6 or more
incorrect entries are made.
Two keys cannot be pressed simultaneously.
Programming a new code will overwrite your
previous code.
TIP! The Vaultek™ app will ask for your safe’s master
code during pairing and anytime you change the
code the app will ask you to re-enter it.
IMPORTANT
Replace the battery when one or more of the following occurs: A) all four of the white LEDs above the micro-USB
jack and blinking or B) it takes than 4 hours to recharge the battery.
Use a 3.7V 18650 rechargeable lithium-ion battery with a at top. A minimum 2000 mAh capacity is required,
however 2200 mAh or higher can be used to increase operation time.
A high capacity battery upgrade is available as an accessory through our website.
The adapter used to charge the battery should output 5V/2000mA or above when using micro-USB.

Continue on next page for more information about the ngerprint scanner.
Programming the 1st and 2nd Fingerprints
The 1st and 2nd ngerprints will be recognized as administrative ngerprints and will be used to authorize
additional users.
Open the safe. Program 1st ngerprint by pressing and
holding the '2' key then the "PROGRAM" button together
(3 seconds)(Figure G) until the screen prompts you to scan
the 1st of ve scans.
Using the helpful programming tips provided on page 11
place your nger on the ngerprint scanner for the 1st of
ve scans. When the safe beeps, and the screen prompts
the next scan remove your nger. If the screen indicates a
failed to complete then start over with step 1.
Place nger again over the scanner until the safe beeps
and the screen prompts the next scan and lift. You will
repeat this process until all scans (1-5) are programmed.
Close lid and test to see if the safe will open using your ngerprint. If you experience issues refer to the helpful
programming tips listed on page 11 or check our tutorials online at vaulteksafe.com under Support/Tutorials.
Repeat steps 1 through 4 to add the 2nd administrative ngerprint.
Continue on next page to program ngerprints 3-20.
Helpful Programming TIPS
Place the core of the ngerprint at (Figure E+F) over
the center of the scanner in line with the side LEDs (this
allows the scanner to read where most of the ngerprint
detail is located) see (Figure E).
Adjust your nger slightly between scans for increased
accuracy.
Excessive moisture, lotions, or dirt will aect your
ngerprint and may cause inaccurate sensor reading.
If you are experiencing diculty try dierent ngers.
Each nger is unique and some ngers, such as your
thumb, contain more readable information than others.
To increase success rate register the same ngerprint
multiple times.
ATTENTION! (Figure F)
Position your nger at against the scanner to
increase the amount of readable information.
G
FIGURE G
authorized users have access to your valuables. The safe is capable of storing ngerprint data for up to 20 unique

Press and hold the '3' key then the "PROGRAM" button together until the safe beeps and the screen prompts you
to enter your master code.
Enter your master code on the keypad. If the code is correct, the safe will beep and the screen will indicate
deletion of all of the ngerprints.
Smart Align Biometric Programming
Programming Additional Fingerprints 3-20
The rst two ngerprints programmed into the safe are the administrative ngerprints. Any additional users
programmed require authorization from one of these ngerprints.
Open the safe. Program additional ngerprints by pressing and holding the '2' then "PROGRAM" button together
(3 seconds)(Figure G on page 12). The screen will prompt you to scan one of the administrative ngerprints.
Place one of the rst two programmed administrative ngerprints on the scanner and remove when the safe
beeps and screen authorizes the print. You can now program a NEW ngerprint.
TIP: If the administrative print is left on the scanner too long the safe will begin to program that ngerprint into
the safe again and not the NEW ngerprint. If this happens start over with step 1.
Using the helpful programming tips provided on page 11 place the NEW nger on the scanner. When the safe
beeps and the screen prompts the next scan remove your nger.
Place nger again over the scanner until the safe beeps and the screen prompts the next scan and lift. You will
repeat this process until all scans (1-5) are programmed.
Table des matières