TRT-BA-IC200/IC300-TC220829TTRT01-001-EN
IC200 / IC300
EN
INSTRUCTIONS
THERMAL IMAGING CAMERA

2 EN
thermal imaging camera IC200 / IC300
Table of contents
Information on the use of this instructions..........................2
Safety .....................................................................................2
Information about the device................................................4
Transport and storage...........................................................7
Operation ...............................................................................7
Software...............................................................................11
PC software..........................................................................17
Emissivity.............................................................................18
Thermography terms...........................................................20
Errors and faults..................................................................21
Maintenance and repair ......................................................21
Disposal ...............................................................................23
Declaration of conformity ...................................................23
Information on the use of this instructions
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
instructions must be observed.
You can download the current version of the instructions and
the EUdeclaration of conformity via the following link:
IC200
https://hub.trotec.com/?id=46837
IC300
https://hub.trotec.com/?id=46838
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
• Do not use the device in potentially explosive rooms or
areas and do not install it there.
• Do not use the device in aggressive atmosphere.
• Do not immerse the device in water. Do not allow liquids to
penetrate into the device.
• The device may only be used in dry surroundings and must
not be used in the rain or at a relative humidity exceeding
the operating conditions.
• Do not point the device at intense energy sources, such as
the sun or laser radiation, in order to avoid damage to the
device.
• Protect the device from permanent direct sunlight.
• Do not open the device.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Observe the storage and operating conditions (see
Technical data).

EN 3
thermal imaging camera IC200 / IC300
Intended use
Only use the device for visual or thermographic representation
of objects whilst adhering to the technical data.
Any use other than the intended use is regarded as misuse.
Reasonably foreseeable misuse
Do not use the device in potentially explosive areas. Trotec
accepts no liability for damages resulting from improper use. In
such a case, any warranty claims will be voided. Any
unauthorised modifications, alterations or structural changes to
the device are forbidden.
Personnel qualification
People who use this device must:
• have read and understood the instructions, especially the
Safety chapter.
Safety signs and labels on the battery
Warning of explosion risk!
These symbols indicate the following:
Do not expose the battery pack or tool to fire or
excessive temperature! Do not let the battery come into
contact with water or fire! Avoid direct sunlight and
moisture. There is a risk of explosion!
Do not open the appliance!
This symbol indicates the following:
This device may only be repaired and serviced by the
manufacturer. Any unauthorised modifications,
alterations or structural changes to the device are
forbidden.
Risk of injury due to electrical voltage. Damage to the
device may occur.
Observe the correct disposal of the battery!
This symbol indicates the following:
Ensure that the battery is disposed of correctly and
never dispose of it in waste water or public waters.
The battery contains irritating, caustic and toxic
substances that pose significant risks to people and the
environment.
Residual risks
Warning of electrical voltage
There is a risk of a short-circuit due to liquids
penetrating the housing!
Do not immerse the device and the accessories in
water. Make sure that no water or other liquids can
enter the housing.
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of explosive substances
Do not expose the batteries to temperatures above
60°C! Do not let the batteries come into contact with
water or fire! Avoid direct sunlight and moisture. There
is a risk of explosion!
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Caution
Lithium-ion batteries might catch fire in case of
overheating or damage. Ensure a sufficient distance to
heat sources, do not subject lithium-ion batteries to
direct sunlight and make sure not to damage the
casing. Do not overcharge lithium-ion batteries. If the
battery is not permanently installed in the device, only
use smart chargers that switch off automatically when
the battery is fully charged. Charge lithium-ion
batteries in due time before they are discharged
completely.
Caution
Keep a sufficient distance from heat sources.
Note
To prevent damages to the device, do not expose it to
extreme temperatures, extreme humidity or moisture.
Note
Do not use abrasive cleaners or solvents to clean the
device.

4 EN
thermal imaging camera IC200 / IC300
Information about the device
Device description
The thermal camera IC200/IC300 creates a visible image
depicting infrared radiation, which is otherwise invisible to the
human eye. The thermal image and temperature are displayed
on the screen in real time. To improve the view, you can select
various colour palettes for depicting the thermal image.
Furthermore, you can superimpose IR and digital images in
order to obtain a higher-contrast thermal image.
The device has an LCDtouchscreen with a screen diagonal of
3.5inches.
For a measured result which is as precise as possible the
ambient temperature, reflected temperature, humidity, distance
and emissivity can be adjusted.
A stepless 16-fold digital zoom allows viewing of distant details.
The focus ring of the IC300 lens additionally allows the desired
measuring object to be focused.
A list of emissivities for various surfaces is provided in the
chapter Emissivity. For a precise evaluation, the thermal image
on the screen can be frozen or saved. The saved images can
later be viewed either directly on the camera screen or on a PC
using an analysis software.
An internal image analysis tool supports the evaluation of the
data, which you can save as photos, IRimages or a fusion of
both, as well as videos.
The USB-C interface enables data transfer and real-time
viewing of the recordings on a PC. The software included in the
scope of delivery (download) is used for external storage and
editing of the recordings.
Device depiction
1
2
3
4
13
12
6
5
7
8
9
10
4
11
No. Designation
1Connectors cover
2Display
3Control panel
4Battery clamps
5Infrared camera lens
6Digital camera lens
7Focus ring (IC300 only)
8Holder for protective cap
9Trigger
10 1/4" tripod thread
11 Battery
12 USB-C port
13 microSD slot

EN 5
thermal imaging camera IC200 / IC300
Battery
16
15
11
14
No. Designation
11 Battery
14 Battery charger
15 Power battery LED
16 Charge battery LED
Control panel
17
18
19
20
21
22
23
No. Designation Meaning
17 Up arrow button Button for menu control
18 On/Off button Switching the device on and
off, switching the temperature
scale
19 Right arrow button Button for menu control
20 Menu/OKbutton Button for menu control,
confirming the selection
21 Down arrow button Button for menu control
22 Left arrow button Button for menu control
23 Play button Opening data memory
Display
24 25 26 27 28 29
30
31
32
33
No. Designation
24 Temperature unit indication
25 Distance unit indication
26 Emissivity indication
27 microSD indication
28 Battery status indication
29 Time indication
30 Upper measuring point indication
31 Temperature scale indication
32 Lower measuring point indication
33 Temperature scale setting indication

6 EN
thermal imaging camera IC200 / IC300
Technical data
Parameter Value
Model IC200 IC300
Measure Temperature range -20 °C to +550 °C 0 °C to +650 °C
Accuracy ±2°C, ±2% of the measured value, at 10°C to 35°C ambient temperature and >0°C object
temperature
Radiometric image
performance
Detector type Focal Plane Array (FPA), uncooled microbolometer
Detector resolution 256x 192 pixels 384 x 288 pixels
Spectral range 8 to 14 µm
Field of view (FOV) 56°x42° 41.1°x31.1°
Geometric resolution 3.5 mrad 1.89 mrad
Thermal sensitivity ≤ 0.1°C at 30°C 0,05°C at 30°C
Refresh rate 25Hz 50Hz
Focus/ min. focus
distance
fixed/ 0.5m manual/ 0.5m
Visual image
performance
Digital photo camera 2 megapixels
Field of view (FOV) 65°
Image
representation
Display 3.5inch touch LCD, 640x 480 pixels
Zoom 16x infinitely variable digital
Image display Pseudo colours, 8 colour palettes
Image display options IR image, real image, DuoVisionPlus display (overlay of infrared and real images in random intensities),
DuoVisionPlus display (fusion of infrared and real image as contour-accentuated detail-enhanced
thermogram), picture-in-picture, auto fusion, zoom
Measurement and
analysis
Measuring spots 1centre spot, 3movable temperature measuring spots (can be freely configured)
Measuring functions Isotherm, line profile analysis, sector analysis (rectangle), various alarm functions, Min/Max temperature
tracking (hot/cold spot), measurements at up to 3temperature measuring points
Area measurement 3 areas
Degree of emission User-defined variably adjustable from 0.01 to 1.0
Measurement correction Emissivity, reflected object temperature, ambient temperature, relative humidity level, object distance
Data storage Memory 3.4GB internal eMMC memory
(> 60minutes video/6000images) plus 16GB microSDcard
Video file format MPEG-4, 640x 480pixels at 30fps
Image file format JPEG or HIRfiles with measurement data; simultaneous saving of IR and real image possible
Interfaces USB type C, Wi-Fi 802.11
Power supply Battery type Li-ion battery (2,600mAh); rechargeable, exchangeable
Operating time approx. 4h
Mains power 5 V, 2.4 A
Energy saving mode User-defined
Ambient conditions Operating and storage
temperature
-15°C to +50°C, -40°C to +70°C (without battery)
Humidity 10% to 90% RH (non-condensing)
Type of protection IP54
Impact resistance
(falling from)
2 m
Dimensions Dimensions 96x 77x 224mm
Weight 500g
Tripod thread ¼inch

EN 7
thermal imaging camera IC200 / IC300
Scope of delivery
• 1x Thermal imaging camera
• 1x USB power adapter
• 1x Battery charging station (IC300 only)
• 1 x USB cable
• 1 x Wrist strap
• 1 x microSDcard
• 1 x Software (via download)
• 1 x Transport case
• 1x Quick guide
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
For transporting the device, use the transport case included in
the scope of delivery in order to protect the device from external
influences.
The supplied Li-ion batteries are subjects to the requirements of
dangerous goods legislation.
Observe the following when transporting or shipping Li-ion
batteries:
• The user may transport the batteries by road without any
additional requirements.
• If transport is carried out by third parties (e.g. air transport
or forwarding company), special requirements as to
packaging and labelling must be observed. This includes
consulting a dangerous goods specialist when preparing
the package.
– Only ship batteries if their housing is undamaged.
– Mask open terminals with tape and pack the battery in
a way that it cannot move inside the packaging.
– Please also observe any other national regulations.
Storage
When the device is not being used, observe the following
storage conditions:
• dry and protected from frost and heat
• protected from dust and direct sunlight
• For storing the device, use the transport case included in
the scope of delivery in order to protect the device from
external influences.
• the storage temperature complies with the values specified
in the Technical data
• Battery/Batteries removed during prolonged storage
Operation
Inserting the microSD memory card
The microSD memory card can be used to extend the device's
internal memory in order to store images and videos.
Please proceed as follows to insert the microSD memory card:
1. Open the rubber cover on the top of the device(1).
2. Push the microSDcard into the slot(13) until it clicks into
place.
ðThe microSD indication(27) appears on the display.
3. Close the rubber cover(1).
Inserting/changing the battery
Note
Make sure that the surface of the device is dry and the
device is switched off.
1. If applicable, remove the empty battery. To do so, press
the clamps on both sides(4) and pull out the battery(11).
4
11
2. Charge the battery as described in the section Charging
the battery in the Maintenance chapter.
3. Reinsert the charged battery until it perceptibly clicks into
place.
11

8 EN
thermal imaging camera IC200 / IC300
Switching the device on
1. Remove the protective cap from the IRlens.
2. Press the Powerbutton(18) for approx.3seconds.
ðThe Trotec logo appears on the display.
ðThe real image is displayed.
3. Wait a moment until the device has started up completely.
ðThe IRcalibrating indication briefly appears on the
display.
ðAfter calibration, a current IRimage appears in the
display and the main menu is displayed.
Manually focussing (IC300 only) and calibrating the
IRcamera
Info
An image that is not sharply focussed leads to
deviations in the temperature measurement!
1. Turn the focus ring(7) to the left or right until the object to
be thermographed is sharply focussed.
ðThe internal shutter of the IR camera closes briefly and
an automatic adjustment (calibration) to the
temperatures in the image section is performed.
ðThe automatic adjustment is performed at regular
intervals.
Freezing the camera image
The camera image can be paused and released as follows:
1. Pull the trigger(9).
ðThe image is frozen and the menu for saving opens.
2. Pull the trigger(9) again.
ðThe display shows the current, movable camera image
again.
Taking/recording an infrared image/video
Please proceed as follows to record and save an image:
1. Pull the trigger(9).
ðThe image is frozen and the menu for saving opens.
ðYou can add text or edit the image settings before
saving.
2. Use the Right arrow button(19) and the Left arrow
button(22) to navigate to the Add text button(35) and add
the desired text. Confirm with theMenu/OK button(20) or
touch the button on the display.
34
35
3. Use the other menus as described in the Software chapter
to edit the image if necessary.
4. Use the Right arrow button(19) and the Left arrow
button(22) to navigate to the Save button(34) and confirm
with the Menu/OK button(20) or touch the button on the
display.
ðThe image is saved with the desired settings.
Please proceed as follows to record and save a video:
1. Pull and hold the trigger(9) for approx. 2seconds.
ðThe image and sound recording is started.
2. Briefly pull the trigger(9).
ðThe recording is saved.

EN 9
thermal imaging camera IC200 / IC300
Setting the temperature scale
You can adjust the temperature scale and thus control the
display of the current camera image. You can choose from the
following options:
• Manual (MANUAL): The user can determine the limit
measuring points and thus the temperature scale
independently. This option helps you visualize even small
temperature differences (see chapter "Thermography
terms").
• Automatic (AUTO): The device constantly adjusts the
temperature span automatically. The relation of
temperature and colour is linear.
• Histogram (HG): The infrared image is enhanced by means
of special algorithms emphasizing the colour differences.
The relation of temperature and colour is not linear.
1. To set the temperature scale manually, tap the
Temperature scale indication (31) until "MANUAL"
appears.
ðA lock icon appears next to the number in the Upper
measuring point indication(30) and Lower measuring
point indication(32).
2. Tap the Upper measuring point indication(30) or Lower
measuring point indication(32) and select the upper or
lower measured value. To do so, tap the arrows to the right
and left of the value or use the Right arrow button(19) and
Left arrow button(22).
3. Tap on a free area next to the settings window to close the
settings window.
ðThe upper or lower measured value is set.
4. Tap the Temperature scale indication(31) again to set the
temperature scale automatically.
ðThe Temperature scale indication(31) shows "AUTO".
ðAn "A" appears next to the number in the Upper
measuring point indication(30) and Lower measuring
point indication(32).
5. Tap the Temperature scale indication(31) again to switch
to histogram display.
ðThe Temperature scale indication(31) shows "HG".
ðAn "H" appears next to the number in the Upper
measuring point indication(30) and Lower measuring
point indication(32).
Info
By briefly pressing the Power button(18) you can
quickly switch between the "MANUAL" and "AUTO"
scales while viewing the current IRimage.
Playing back images and videos
In playback mode, you can view and edit stored images and
videos. To do so, please proceed as follows:
1. Press the Playbutton(23) to open the playback mode.
2. Tap the arrows on the left and right of the display to scroll
through the stored images and videos.
ðThe Sequence number indication(37) shows the
number of the stored file.
In playback mode, you have the following options:
36 37 38 39 40
41
No. Button
36 Exit playback mode
38 Edit image
39 Show information on image/video
40 Delete image/video
41 Play video

10 EN
thermal imaging camera IC200 / IC300
1. Press the Play video button(41) to play a video. Press the
button again to pause the video.
2. Press the Edit image button(38) to edit a stored image.
ðYou have the same options as for a newly taken image
(see section Taking/recording an infrared image/video
and chapter Software).
3. Press the Info button(39) to display more detailed
information on the image/video.
ðThe recording date, time and thermal resolution are
displayed.
4. Press the Delete button(40) to delete the image/video.
5. Press the Exitbutton(36) to exit the playback mode.
Data transfer via USB
You can either access the microSD memory card inserted in the
device using a USB-C data cable, or transfer the data to the
optionally available IR-ReportNG PCsoftware in real time and
thus record fully radiometric infrared videos.
To do so, first select the desired transmission mode in the
settings:
•PC Connection (data memory access)
•PC Camera (real-time data transmission to software)
1. Press the Menu/OKbutton(20).
ðThe main menu will be displayed.
2. Select the Device Setting menu.
3. Select the submenu USB Mode.
4. Select the desired transmission mode.
5. Connect the supplied USB-Cdata cable to the device's
USB-Cport(12).
6. Connect the data cable to a PC or notebook.
7. Use the Menu/OK button(20) to confirm the connection or
tap the OK button.
ðIn PC Connection transmission mode, the display shows
USB CONNECTED.
ðIn PC Camera transmission mode, the current camera
image is displayed.
Info
To view the real-time images in the IR-ReportNG
PCsoftware, please follow the instructions in the
software documentation.
Switching the device off
1. Press the Power button(18) for approx. 3seconds.
2. Confirm the prompt with the Menu/OK button(20) or tap
the OK button.
ðThe device will be switched off.
If desired, the device will switch off automatically after a preset
time. This time can be set in the submenu Auto Power Off (see
chapter Software).
Autres manuels pour IC200
1
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels Trotec Caméra thermique

Trotec
Trotec XC300 Manuel utilisateur

Trotec
Trotec IC085LV Manuel utilisateur

Trotec
Trotec IC200 Manuel utilisateur

Trotec
Trotec AC060V Manuel utilisateur

Trotec
Trotec AC060V Manuel utilisateur

Trotec
Trotec AC060V Manuel utilisateur

Trotec
Trotec ec020 Manuel utilisateur

Trotec
Trotec AC080V Manuel utilisateur