Trotec AC060V Manuel utilisateur

TRT-BA-AC060V-TC2018-67-001-EN
AC060V
EN
OPERATING MANUAL
THERMAL IMAGING CAMERA

2 EN
thermal imaging camera AC060V
Table of contents
Notes regarding the operating manual.................................2
Safety .....................................................................................2
Information about the device................................................4
Transport and storage...........................................................6
Operation ...............................................................................6
AC060V app............................................................................9
Emissivity.............................................................................17
Errors and faults..................................................................19
Maintenance and repair ......................................................20
Disposal ...............................................................................20
Notes regarding the operating manual
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
operating manual must be observed.
You can download the current version of the operating manual
and the EU declaration of conformity via the following link:
AC060V
https://hub.trotec.com/?id=42959
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged from
8years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
• Do not use the device in potentially explosive rooms.
• Do not use the device in aggressive atmosphere.
• Do not immerse the device in water. Do not allow liquids to
penetrate into the device.
• The device may only be used in dry surroundings and must
not be used in the rain or at a relative humidity exceeding
the operating conditions.
• Protect the device from permanent direct sunlight.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Do not open the device with a tool.
• Observe the storage and operating conditions as given in
the Technical data chapter.

EN 3
thermal imaging camera AC060V
Intended use
Only use the device for visual or thermographic representation
of objects whilst adhering to the technical data.
To use the device for its intended use, only use accessories and
spare parts which have been approved by Trotec.
Improper use
Do not use the device in potentially explosive areas. Never use
the device on persons or animals. Trotec accepts no liability for
damages resulting from improper use. In such a case, any
warranty claims will be voided. Any unauthorised modifications,
alterations or structural changes to the device are forbidden.
Personnel qualifications
People who use this device must:
• have read and understood the operating manual, especially
the Safety chapter.
Residual risks
Hazardous electric current
Work on the electrical components must only be
carried out by an electrically skilled person or an
authorised specialist company.
Warning of electrical voltage
There is a risk of a short-circuit due to liquids
penetrating the housing!
Do not immerse the device and the accessories in
water. Make sure that no water or other liquids can
enter the housing.
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket and the battery from the device!
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning of explosive substances
Do not expose the battery to temperatures above
45°C! Do not let the battery come into contact with
water or fire! Avoid direct sunlight and moisture. There
is a risk of explosion!
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Caution
Keep a sufficient distance from heat sources.
Note
To prevent damages to the device, do not expose it to
extreme temperatures, extreme humidity or moisture.
Note
Do not use abrasive cleaners or solvents to clean the
device.

4 EN
thermal imaging camera AC060V
Information about the device
Device description
The thermal camera AC060V creates a visible image depicting
infrared radiation, which is otherwise invisible to the human
eye. The thermal image and temperature are displayed on the
screen in real time. To improve the view, you can select various
colour palettes for depicting the thermal image.
You are also able to automatically find and display the warmest
and coolest measuring spot in the measured image.
For a measured result which is as precise as possible the
ambient temperature, relative humidity, distance and emissivity
can be entered.
A list of emissivities for various surfaces is provided in the
chapter Emissivity.
For a precise evaluation, the thermal image on the screen can
be recorded and saved on the device.
The device control is based on the Android operating system for
tablets.
The saved images can either be viewed directly on the screen or
transferred to a PC with the supplied USB cable.
To edit the images, you can download the IR-Report 2.X STD
software from the download (or service) section of
www.trotec.com.
Info
This operating manual only describes the operation of
the IR app for the AC060V. Further functions of the
tablet or the Android operating system are not a part of
this manual.
Additionally, to create short reports relating to the images, you
can use the app IR-Wizard available free of charge. This
software is a complimentary bonus that does not belong to the
standard scope of delivery and is offered for use without support
or warranty. The program interface (only available in selected
languages) is generally easily comprehensible and can be used
intuitively. Further information regarding the use is provided in
the application.
Device depiction
1
2
3
4
5
6
7
8
9
10
11
12
13
No. Operating element
1 Protective cover for micro USB and headphone
connection
2 Touchscreen
3 LED illumination
4 Infrared camera
5 Battery compartment with cover
6 Locking mechanism for the battery compartment
7 USB port
8 3.5mm headphone connection
9 Power button
10 Volume control button
11 Camera (visual)
12 Photo button (IR picture)
13 Shutter button

EN 5
thermal imaging camera AC060V
Technical data
Parameter Value
Model AC060V
Article number 3.110.003.030
Measurement Temperature range -20 °C to +160 °C
Accuracy ± 2 °C, ± 2 % from the measured value
Radiometric image
performance
Detector type UFPA
Detector resolution 80 x 80 pixels
Spectral range 8 to 14 µm
Field of vision (FOV) 21° x 21°
Geometric resolution 4.1 mrad
Thermal sensitivity ≤0.1°C at 30°C
Refresh rate 50 Hz
Focus / min. focus distance Rigid / 0.5 m
Visual image
performance
Digital photo camera 8 megapixels, integrated photo lamp(LED)
Video norm PAL / NTSC
Image
representation
Display 5.5-inch LCD touchscreen, capacitive
Image display Pseudo colours, 6 colour palettes (IR image); 16.7 million colours (real image)
Image display options IR image, IR video, real image
Measurement and
analysis
Measuring points 3dynamic temperature measuring points, individually configurable (MIN, MAX, ALARM)
Measuring functions Automatic min./max. temperature tracking (hot/cold spot), isotherm, sector analysis (line,
circle, rectangle), alarm function
Emissivity User-defined variably adjustable from 0.01 to 1.0
Measurement correction Correction of the reflected object temperature; automatic correction based on user-defined
specifications for ambient temperature, distance, relative humidity
System equipment Operating system and functions Operating system based on Android4.2 with integrated thermal image analysis software,
report generating function, IR video player, internet browser
Interfaces USB, WLAN, GPS, Bluetooth, 3.5mm headphone output
Data storage Memory 16 GB integrated and non-exchangeable SD card
File format Radiometric image: 14 bit JPEG; visual image: JPEG; non-radiometric thermographic video:
MPEG-4
Power supply Battery type Standard, lithium-ion; rechargeable
Operating time ≈ 2 h
Surrounding
conditions and
physical
characteristics
Temperature 0 °C to +50 °C (operation), -25 °C to +55 °C (storage)
Type of protection IP54
Shock / vibration 25 G / 2 G
Dimensions 173x 100x 28mm
Weight 415g
Scope of delivery
• 1 x Thermal camera AC060V
• 1 x Rechargeable battery, Li-ion
• 1 x Charger
• 1 x Charging cradle
• 1 x Changing adapter for different socket types
• 1 x USB cable
• 1 x Transport case
• 1x Manual

6 EN
thermal imaging camera AC060V
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
For transporting the device, use the transport case included in
the scope of delivery in order to protect the device from external
influences.
The supplied Li-ion batteries are subjects to the requirements of
dangerous goods legislation.
Observe the following when transporting or shipping Li-ion
batteries:
• The user may transport the batteries by road without any
additional requirements.
• If transport is carried out by third parties (e.g. air transport
or forwarding company), special requirements as to
packaging and labelling must be observed. This includes
consulting a dangerous goods specialist when preparing
the package.
– Only ship batteries if their housing is undamaged.
– Mask open terminals with tape and pack the battery in
a way that it cannot move inside the packaging.
– Please also observe any other national regulations.
Storage
When the device is not being used, observe the following
storage conditions:
• dry and protected from frost and heat
• protected from dust and direct sunlight
• For storing the device, use the transport case included in
the scope of delivery in order to protect the device from
external influences.
• The storage temperature is the same as the range given in
the Technical data chapter.
• When storing the device for an extended period of time,
remove the battery/batteries.
Operation
Operating elements (AC060V app only)
17
15
16
14
18
19
20
21 23
22
26
25
24
No. Operating elements
14 Settings menu button
15 Temperature scale
16 Camera control panel
17 Mode menu bar
18 Functions menu bar (example here: Analysis)
19 Parameter button
20 Charging status indicator
21 Menu button
22 Home button
23 Back button
24 Still image button
25 Calibration / automatic adjustment button
26 Button to change between IR camera and visual camera

EN 7
thermal imaging camera AC060V
Inserting / Changing the battery
Note
Make sure that the surface of the device is dry and the
device is switched off.
1. Slide the locking bar of the battery compartment to the left.
ðThe battery compartment's lock is released.
2. Remove the cover(5) from the battery compartment.
3. Insert the battery into the compartment as indicated in the
above figure.
4. Reattach the cover(5) to the battery compartment.
5. Slide the locking bar to the right.
ðThe battery compartment is closed and locked.
Switching the device on
1. Press the Power button(9) for approx. 3 seconds.
ðThe display switches on.
ðThe operating system boots up.
ðThe device is ready for operation.
Setting the language
The app's language is controlled via the system settings of the
Android operating system.
1. Call up the system settings. The system settings app has
the following icon:
2. Find the menu item Language & input.
3. Set the desired language.
4. Press the Back button(23) to leave the system settings.
Setting the time and date
Time and date of the app are controlled via the system settings
of the Android operating system.
1. Call up the system settings. The system settings app has
the following icon:
2. Find the menu item Date & Time.
3. Adjust the time and date as desired.
4. Press the Back button(23) to leave the system settings.
Starting the AC060V app
In order to use the IRcamera first start the AC060V app via the
Android user interface.
1. Touch the icon on the user interface.
ðThe app starts.
ðThe IR camera will be activated.
ðThe thermal image will be displayed in real time.
Further information regarding the operation of the app can be
found in the chapter AC060V app.

8 EN
thermal imaging camera AC060V
Calibrating the IRcamera
1. Press the Shutter button(13).
ðThe internal shutter of the IR camera closes briefly and
an automatic adjustment (calibration) to the
temperatures in the image section is performed.
You can also calibrate the IRcamera via the AC060V app. To do
so, please proceed as follows:
1. Start the AC060V app.
2. Press the Calibration button(25).
ðThe internal shutter of the IR camera closes briefly and
an automatic adjustment (calibration) to the
temperatures in the image section is performed.
25
Taking/recording an infrared image/video
1. Start the AC060V app.
2. Change over to the Image or Analysis mode.
3. Point the camera at the object which you want to have a
thermal image of.
4. Calibrate the IR camera (see Calibrating the IRcamera).
5. Either press the Photo button(12) or the camera icon on
the display (Image mode).
Data transfer via USB
1. Connect the supplied micro USB data cable to the device.
2. Connect the data cable to a PC or notebook.
3. If the camera is not recognized by the computer, select the
function use as data store when prompted:
ðTo do so, open the Android USB settings by swiping the
screen from the top edge to the bottom.
ðAfter successful detection the camera is displayed in
the file browser of your PC/notebook as removable
storage device; from there files can be transferred.
Switching the device off
1. Press the Power button(9) for approx. 3 seconds.
2. Confirm the switch-off by pressing the button Power Off.
ðThe device switches off.

EN 9
thermal imaging camera AC060V
AC060V app
Basic settings
In this menu you can set the automatic calibration and view
information regarding the device.
Setting the automatic calibration
You can specify the time after which the camera carries out an
automatic adjustment.
1. Press the Settings button(14).
ðThe menu will be displayed.
2. Touch the selection Auto Shutter Time.
ðThe submenu for setting the time for an automatic
calibration will be displayed.
3. Select the desired time or disable automatic calibration.
4. Press Confirm to confirm and save the selection. If you do
not want to save the change, press Cancel.
5. Press the Back button(23) to leave the menu.
Info
If the automatic adjustment function of the camera is
deactivated, it needs to be calibrated manually at
regular intervals during operation, particularly before
taking a picture, as owing to its operating principle the
IR detector drifts and the camera could consequently
display incorrect temperature values!
Displaying device information
1. Press the Settings button(14).
ðThe menu will be displayed.
2. Select Device Info.
ðThe device information will be displayed.
3. Press the Back button(23) to leave the device information.
Advanced settings
1. Press the Parameter button(19).
ðThe parameter menu bar will be displayed.
32
31
30

10 EN
thermal imaging camera AC060V
2. Press the desired button to access the corresponding
menu:
ðNo.(30) calls up the Parameter menu.
ðNo.(31) calls up the Colour settings menu.
ðNo.(32) calls up the Photo settings menu.
3. Press the Back button(23) to close the menu bar.
Parameter menu
In this menu you can adjust general parameters such as the
ambient temperature or the emissivity.
1. Touch the parameter you want to edit.
ðA submenu with setting options for the selected
parameter will be displayed. Displayed in our example is
the submenu for the ambient temperature.
ðThe following parameters can be selected:
Ambi. Temperature = Setting the ambient temperature
Humidity = Setting the humidity level
Emissivity = Setting the emissivity
Distance = Setting the distance to the measuring object
Refl. Temperature = Setting the average value of the
reflected temperatures from heat sources located in the
background, which could influence the object to be
thermographed.
Unit Settings = Setting the units used (metric, imperial)
Temperature Level = Setting the measuring range
2. Select the desired value for the parameter.
3. Press Confirm to confirm and save the selection. If you do
not want to save the change, press Cancel.
4. Press the Back button(23) to leave the menu or briefly
touch a free area on the touch screen.
Colour settings submenu
In this submenu you can select the colour palette for the
representation of the temperatures in the thermal image.
1. Press the button with the desired setting. The colour
palette will be applied immediately and is visible in the
background.
2. Press the Back button(23) to leave the submenu or briefly
touch a free area on the touch screen.
ðThe settings will be saved.
Autres manuels pour AC060V
2
Table des matières
Autres manuels Trotec Caméra thermique

Trotec
Trotec IC200 Manuel utilisateur

Trotec
Trotec ec020 Manuel utilisateur

Trotec
Trotec AC080V Manuel utilisateur

Trotec
Trotec AC060V Manuel utilisateur

Trotec
Trotec IC085LV Manuel utilisateur

Trotec
Trotec AC060V Manuel utilisateur

Trotec
Trotec XC300 Manuel utilisateur

Trotec
Trotec IC200 Manuel utilisateur