Enter your access code and press the button OK in the opened
indo Access code (default access code is 123 ).
If you ant CG5config to remember your access code check the
box Remember. Then the Access code indo ill not open,
hen connecting to the module for the next time.
6. Set the follo ing parameters in the directory SMS reporting.
Access code Default access code 123 must be changed to one kno n by you and other
authorised persons only. This code is used for setting operating parameters of the
module and/or to control the state of output OUT1 ith SMS messages. When
changing the pass ord, enter a desired four-digit sequence.
Account name If desired, enter the name of the object. Account name ill be included in SMS
messages.
SMS te t encoding Select the format of SMS text encoding in the drop-do n list.
Operation mode Select the desired module CG5 operating mode: either 24 h or Control panel. If there
is set NO or NC type, all five inputs ill respectively become either NO or NC. If there
is set EOL type, inputs IN1...IN4 ill become EOL=2.2kΩ and the input MCI – NC.
Output Select the desired output OUT1 operating mode. If you connect a siren to the output,
select the option Siren. If you ould like that after receiving a command ith SMS
message, the module ould change the state of its output, select the option Remote
control by SMS.
Test time Enter a desired time period according to hich the module ill send a periodic
message ith text entered in the ro Test.
Call When event occurs module ill call to User pre-set number of times.
7. Choose the directory SMS reporting and set desirable parameters used for reporting.
Zone alarm/restore events can be described ith a text. Enter your texts in appropriate text-boxes. When input
circuit is disturbed, an SMS message ill be sent ith text from the appropriate text-box Event message. When
input circuit is restored – from the text-box Restore message. Texts hich describe events in po er supply
chain can be entered in the box LP. There can be entered desirable text hich ill be included in periodic
message in the box Test.
Telephone number Enter the GSM numbers of mobile phones, to hich the module ill send SMS
messages and/or ill make calls. Module parameters can be set or the state of
output OUT1 can be controlled by sending SMS messages only from phones having
these numbers. GSM numbers should be entered ith international country code
ithout the “+” (plus) sign.
By checking boxes belo the GSM numbers, you can choose ho each recipient ill be alerted and hich type
of messages ill be sent to them:
SMS SMS messages ill be sent hen appropriate input circuit is broken (box E) and
restored (box R),
Call A call ill be made to alert that appropriate input circuit is broken (box E) and
restored (box R),
LP SMS messages ill be sent hen informing about disturbances in po er supply chain,
Test Module shall send test messages to the recipient according to the time period set in
the field Test every.
ACK Module CG5 shall send confirmation about command execution to the recipient ho
has sent the command.
8. Press the button Save [F6] and set configuration ill be uploaded to Module CG5.
9. Press the button Disconnect [F8] and unplug USB cable.
A set configuration file can be created ith extention .gst and saved in the computer by the pressing the
button Save [F5]. The file as a templet can be used in the future.
If you need to restore Module CG5 default parameters, press the button Restore [F11] and press the button
Confirm hen request indo ne ly opens. Module CG5 default operating parameters can be restored any
time before unplugging the USB cable.
Module firmware version updating
When the manufacturer adds ne features to the Module CG5, firm are of the previously bought CG5 can be
updated:
1. Do nload the latest CG5_xxx.prg update file from the ebsite .trikdis.lt.
2. Connect the Module CG5 to a computer and start the CG5config program. Select the directory Firmware
in program CG5config and select the do nloaded update file CG5_xxx.prg.
3. Firm are update ill start after pressing the button Start [F9]. Wait until Progress bar reaches 100%,
then press the button Disconnect [F8] and unplug the USB cable.
4. Plug the USB cable back in and press one by one the buttons Connect [F2] and Read [F7]. The ne
version of Module firm are ill be displayed in status bar of the program CG5config. No you can set
additionally configuration according to the manner described in previous chapter. If you don’t need this,
press the button Disconnect [F7] and unplug USB cable.
Setting of operating parameters with SMS messages
Some Module operating parameters can be set by sending SMS messages from authorised phone to the GSM
number of the SIM card inserted in the Module. If function ACK for confirming SMS commands is set, Module
ill send back SMS messages ith confirmations that: COMMAND OK, Wrong COMMAND!!!, Wrong
PASSWORD!!!, Wrong DATA!!!.
-SMS syntax: <Command>space<Password>spaces<Data>
-For example: SETN 1234 PHONE1=+37068700000
Here: SETN – command
1234 – pass ord
PHONE1=+37068700000 – data
Note: All commands in SMS message have to be ritten in capital letters.
Ser No Command Content Meaning
1 SETL
ENG
RUS
LIT
Setting of language:
-English
-Russian
-Lithuanian
For example: SETL 1234 ENG
2 SETN
PHONE1=+370xxx
PHONE2=+370xxx
PHONE3=+370xxx
PHONE4=+370xxx
PHONE1=DEL
PHONE2=DEL
PHONE3=DEL
PHONE4=DEL
Entering of recipients’ telephone numbers:
-1st GSM number
-2nd GSM number
-3rd GSM number
-4th GSM number
For example: SETN 1234 PHONE1=+37068700000
Deleting of recipients’ telephone numbers:
-1st GSM number
-2nd GSM number
-3rd GSM number
-4th GSM number
For example: SETN 1234 PHONE1=DEL
3 SETE
TEST
ACK
CALL
SMS
Distributing of messages by their type:
-Enabling sending of Test message
-Enabling sending of ackno ledgements about
command executing
-Enabling calling if event happens
-Enabling SMS sending if event happens
For example: SETE 1234 PHONE1=... TEST=ON ACK=ON
CALL=OFF SMS=ON
4 TXTA
<Text>
Setting of object name:
For example: TXTA 1234 Object name
5 TXTE
Z1=<Text>
........
Z6=<Text>
Customising of SMS with alarm text:
-Z1...Z6 – input number
For example: TXTE 1234 Z1=ALARM in Zone1
6 TXTR
Z1=<Text>
........
Z6=<Text>
Customising of SMS with restore text:
-Z1...Z6 – input number
For example: TXTR 1234 Z1=Restore Zone1
7 TIME
<Time>
Setting of internal clock:
For example: TIME 1234 YYYY/MM/DD,12:00:00
8 PSW
Ne PSW
Setting of password:
-Ne pass ord (4 digit)
For example: PSW 1234 4321
9 RESET Module reset:
For example: RESET 1234
10 INFO Request for info about module state:
For example: INFO 1234
11 SLEEP Stop sending of SMS that have been unsent till RESE
command:
For example: SLEEP 1234
Remote switching of PGM output OU 1
In order to change state of output OUT1 you need to send an SMS message to the Module by GSM number of SIM
card inserted in it. Examples of SMS messages are provided in the table belo .
Note: All commands have to be ritten in capital letters.
SMS syntax Meaning Pataba
OUTPUT 1234 ON Output turns to position ON (circuit closes) 123 – default pass ord. Instead
of this, enter your.
OUTPUT 1234 OFF Output turns to position OFF (circuit opens)
OUTPUT 1234 PULSE=005 Output turns to position ON for entered time (sec)
Note: Output state can be s itched then hen both operating mode of the Module is set as 24h and output operating mode
is set as Remote control by SMS only.