TMB IMS Mk2 Manuel utilisateur

Menu Map
Level 1
Level 2
Level 3
Notes
Set DMX
addr 1-512 Set the DMX start address
Select
type Select LED lamp model
RGB + White
Dynamic W
Filament
Test
lamps
In this menu function you can select the fixture
control options.
LAMP OFF
No test
RED
Red color test
GREEN
Green color test
BLUE
Blue color test
WHITE
White color test
R+G
Red + green color test
R+B
Red + blue color test
R+W
Red + white color test
G+B
Green + blue color test
G+W
Green + white color test
B+W
Blue + white color test
R+G+B
Red + green + blue color test
G+B+W
Green + blue + white color test
R+G+W
Red + green + white color test
R+B+W
Red + blue + white color test
R+G+B+W
Red + green + blue + white color test
RUN LINE
Test a IMS output with DMX coming from the
Hand Held Programmer

RAINBOW
Rainbow color mix test
Settings
Off time
Set the time after which the Hand Held
Programmer will power off.
0-10
0 - never
1-10 - time in minutes
Volume
Set the volume level.
0-7
0 - mute
1-7 - higher the number, higher the volume
About
Information about software version for the device
and current lamp firmware version.
Overview

What is the function of IMS Mk2 HHP
The IMS Mk2 (Intelligent Marquee Systems) HHP (Hand Held Programmer) has two
primary uses:
1) Programming the IMS lamps
User needs to DMX address each lamp and upload new firmware into the lamps. As
the need arises for lamp readdressing and replacement, the IMS HHP is a
convenient, powerful, and portable tool.
2) Testing the IMS lamps
The HHP can test all IMS lamps, as well as output a test sequence to an IMS
Universe Drive via DMX to test a lamp string.
Turning the device ON
Press and hold the <POWER> button until the device powers ON.
"Set DMX address" submenu will automatically open.
To return to the main menu, press the <ESCAPE> button.

Main menu
The Main menu has 4 submenus:
Set DMX address
Select type
Test lamps
Settings
Choose the desired submenu by pressing the <UP> or <DOWN> buttons and
pressing the <SELECT> button to confirm the selection.
Set DMX address submenu
This submenu is for setting the DMX address of a connected IMS Lamp. If no lamp is
connected to the HHP, screen with "NO LAMP"notification will appear.
Connecting the lamp to HHP
When connecting an IMS lamp to the HHP, the lamp will begin flashing and the HHP
will make an audible sound notification (if the volume setting is set at 1 or higher).

The screenshot below shows an example for a lamp connected to the HHP. The
current DMX address, the lamp number in the lamp chain, firmware version and lamp
type is displayed
Element explanation (marked with red circles):
1) Current DMX address of lamp
2) Lamp number in the lamp chain; (useful for quick addressing by the nth lamp)
3) Software version that will be uploaded to lamp
4) Mode that will be patched in the lamp
5) DMX address that will be programmed in the lamp
6) Sequence number for the lamp that will be programmed
Lamp error
If there is a problem with a lamp, it will show an "ERROR" message in the middle of
the screen. If this happens, please contact TMB Tech support (see contact
information on last page).

Setting the DMX address
To set the DMX address, use the <RIGHT> and <LEFT> buttons to select the DMX
address for the lamp to be programmed.
Using the <UP> and <DOWN> buttons, the lamp can be addressed by the lamp
number to patch in the line. (This automatically chooses the next DMX address
making programming simple and quick.)
When the correct DMX address has been selected, press the <PROGRAM> button.
When programming is completed, the HHP will play back a notification sound (if the
volume setting is set at 1 or higher). Confirmation of a successful lamp programming
shows the DMX address changed to the programmed address, and next incremental
address will be displayed below for easy and quick sequential programming. No
intervention is necessary, and lamps can be quickly programmed in succession by
swapping to the next lamp and pressing the program button.
Example – The current DMX address for the connected lamp is 1; the lamp number
in lamp chain is #1. After pressing <PROGRAM> button, the HHP will set the DMX
address to 5 (for RGB+W lamps) and the sequence number for a lamp will change to
#2.

Examples for IMS lamp connections
Dynamic White LED lamps connected. Three lamps are shown. Dynamic white
lamps have a two DMX channel footprint.
Warm White Clear Filament LED lamps connected. 3 lamps are shown. Warm White
Clear filament lamps have a 1 DMX channel footprint.

RGB+W LED lamps connected. 3 lamps are shown. RGBW+W lamps have a 4 DMX
channel footprint.
Example for mixed LED lamps:
#1- RGB + white
#2- Warm White Clear Filament
#3- Dynamic White

Settings submenu
Off Time
This setting sets the amount of time of no usage after which the device will turn off by
itself.
The time can be changed by using the <UP> and <DOWN> buttons. When the
desired time has been chosen, press the <SELECT> button to store the new setting.
To return to the previous menu without making changes, press <ESCAPE> button.
Value
Reaction
0
Device will never turn off automatically
1-10
Device will turn off in time 1-10 minutes
Table des matières
Manuels Carte mère populaires d'autres marques

Telit Wireless Solutions
Telit Wireless Solutions SL869-3DR Manuel utilisateur

Gigabyte
Gigabyte GA-9IVDT Manuel utilisateur

Texas Instruments
Texas Instruments ADS8372EVM Manuel utilisateur

Commell
Commell MS-C73 Manuel utilisateur

IBT Technologies
IBT Technologies MB860 Manuel utilisateur

Nvidia
Nvidia TEGRA DG-04927-001_V01 Manuel utilisateur