Installation (Continued)
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON.
1. The Gas Ovens do not require an electrical connection, as they function totally on the as
supply only.
2. It is essential that the as supply is correct for the appliance to be installed and that
adequate supply pressure and volume are available. The followin checks should
therefore be made before installation:-
a. Gas Type required for the appliance is shown in the ratin label. Check that this is correct for
the as supply the appliance is bein installed for. The as conversion procedure is detailed
in this manual.
b. Supply Pressure required for this appliance is shown in the ‘Gas supply requirements’ section
of this manual. Check the as supply to ensure adequate supply pressure exists.
c. Input Rate of this appliance is stated on the Ratin label .The input rate should be checked
a ainst the available as supply line capacity. Particular note should be taken if the appliance is
bein added to an existin installation.
NOTE: It is important that adequately sized pipin runs directly to the connection joint on the
appliance with as few tees and elbows as possible to ive maximum supply volume.
NOTE: Ensure the re ulator is converted to the correct as type that the appliance will operate on. The
re ulator outlet pressure is fixed ex-factory for the as type .
3. Correctly locate the appliance into its final operatin position and usin a spirit level, adjust
the le s so that the unit is level and at the correct hei ht.
4. Connect the as supply to the appliance throu h the re ulator. A suitable jointin compound
which resists the breakdown action of propane must be used on every as line connection,
unless compression fittin s are used.
5. Check all as connections for leaka es.
WARNING:
DO NOT USE A NAKED FLAME TO CHECK FOR GAS
LEAKAGES
.
6. Check that the as operatin pressure.
7. Turn off the mains as supply and bleed the as out of the appliance as lines.
8. Turn on the as supply and the appliance.
9. Verify the operatin pressure remains correct.
Low Flame Setting
Check the low flame settin by li htin the oven and heatin to a set temperature. When the set temperature
has been reached the thermostat will reduce the oven burner flame to its low rate. Check that rapid closin of
the oven door does not extin uish the flame. If necessary, adjustment to the low flame settin is made by
removin the oven knob and turnin the bypass adjustment screw (Clockwise to decrease and anti-clockwise
to increase the flame). Care should be taken, as the appliance will become hot durin commissionin .
Note: To obtain the above burner pressures adjust the re ulator as supplied with the unit. When the correct
operatin pressure has been obtained then re-assemble unit.
WARNING: Failure to check and set the oven low flame setting may initiate an un-necessary
service call due to the oven burner "going out".