Terwin 2000 Series Manuel utilisateur

Page 1 of 4
2000 Series Installation & Instruction Manual (B)
Last printed 12/03/2007 11:26:00
Terwin Instruments Ltd.
2000 SERIES PRESSURE / TEMPERATURE TRANSDUCER
INSTALLATION AND CALIBRATION INSTRUCTIONS
IMPORTANT NOTICE !
The 2000 series pressure / temperature transducers are precision instruments and it is
important to follow the instructions below to avoid unnecessary damage.

Page 2 of 4
2000 Series Installation & Instruction Manual (B)
Last printed 12/03/2007 11:26:00
HANDLING
The transducers should be handled with great care. They should not be dropped and the front diaphragm should be prevented fr om coming into contact
with sharp objects. Under no circumstances should the diaphragm be cleaned with a wire brush or abrasive cleaners. If the transducers require cleaning,
use only a clean cloth when the transducer is hot and at around the same temperature as the material which was previously being processed. Additionally,
always ensure that before removing a transducer from an extruder, the processed material is still at its working temperature. If the material being extruded
has become cold, this could lead to the diaphragm being damaged when the transducer is removed.
UNDER NO CIRCUMSTANCES MUST THE TRANSDUCER BE REMOVED FROM THE EXTRUDER WHILST UNDER PRESSURE!
BEFORE INSTALLATION
Always ensure that the mounting hole conforms to the required dimensions that are shown on the reverse of this leaflet, and that it is clean and entirely
free of old processed material that may damage the transducers sensitive diaphragm.
INSTALLATION
Lubricate the threads of the transducer before each installation with Dow Corning Molycote G or a similar product. Screw the transducer into the extruder
and torque to 20ft lbs. maximum - 10ft lbs. minimum. DO NOT over torque as this may lead to the transducer being damaged beyond repair.
RECOMMENDED PORT DIMENSIONS
ELECTRICAL CONNECTIONS
Please refer to the calibration data sheet which is sent out with each 1000 / 2000 & 2200 series pressure transducer, full electrical connections /
specifications are detailed on this.
CALIBRATION Note: All adjustments are to be made at zero pressure.
1) Ensure that the pressure transducer is at working temperature and power has been applied to the measuring instrument.
2) Adjust the ZERO screw on the measuring instrument until a true zero reading is achieved. (For Auto zero and calibration. ins truments, see their
instruction manuals.)
3) Press the “SPAN” or “CALIBRATION” switch on the measuring instrument and adjust the SPAN or CAL screw so the instrument display matches
the calibration figure that is printed on the pressure transducer. This value is stated in both percentage of full-scale range and also in psi, bar etc.,
if a 10,000psi transducer has a calibration value of 80%, this calibration will also be expressed as 8,000psi.
4) Re-check the zero reading and adjust again if necessary and then repeat the Span/CAL adjustment as detailed above in section 3).
CAUTION:- DO NOT make ANY adjustments when there is pressure on the transducer. This could cause the pressure reading to be low, resulting
in the machine being over pressurised.
COLD STARTS
Always ensure that the processed product has reached the correct extrusion temperature before the screw is run. Failure to adhere to this instruction may
lead to the transducer sensing diaphragm being damaged.
44.5 (1.75) MAX. DEPTH
5.84 ±0.10 (0.230 ±0.004)
9.53 (0.375)
45°
+1°
-0
15.9 (0.626) DIA
C'BORE
19.1 (0.75) MIN.
10.72±0.03DIA
(0.422±0.001)
7.95±0.03 DIA.
(0.313±0.001)
1/2" - 20 U.N.F. - 2B

Page 3 of 4
2000 Series Installation & Instruction Manual (B)
Last printed 12/03/2007 11:26:00
SERVICING
If repairs are required, the pressure / temperature transducer should be adequately packed to prevent damage, with a note describing the observed
problems and shipped pre-paid to your nearest Terwin representative or:-
WARRANTY
Terwin Instruments Limited warrants equipment of its manufacture against defects in materials and workmanship for a period of one year from date of
despatch. Terwin Instruments Limited’s obligation under warranty is expressly limited to the repairing or replacing at its factory, or at any authorised
representatives repair station, providing that:
(a) Terwin Instruments Limited is promptly notified by the buyer upon his/her discovery of a defect.
(b) The defective equipment is returned, with transportation charges pre-paid by the buyer.
(c) Providing the defective unit has not been damaged by negligence, improper use or unauthorised repair or alteration.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE WHETHER TO THE ORIGINAL PURCHASER OR TO ANY OTHER PERSON. TERWIN INSTRUMENTS LIMITED SHALL NOT BE LIABLE FOR
CONSEQUENTIAL DAMAGE OF ANY KIND.
The aforementioned provisions do not extend the original warranty period of any article that has been either repaired or replaced by Terwin Instruments
Limited.
Terwin Instruments Limited shall not be bound by any terms, conditions, representations or warranties, expres sed or implied, which are not stated herein.

Page 4 of 4
2000 Series Installation & Instruction Manual (B)
Last printed 12/03/2007 11:26:00
Try This Product To Help Installation Problems:
Terwin Pressure Transducer Simulator
Length 90mm x Width 55mm x Depth 40mm
Model Shown: Simulator D6/D8 (Also available with G or D9 connectors)
Description:
The Terwin pressure transducer simulator has been designed as a service aid to engineers that are involved in the extrusion
of plastics, rubber and food.
Should a fault occur on an extrusion pressure monitoring / control system, the simulator will enable the plant engineer to
check both the cable assembly and associated indicator / controller / signal conditioner by simply plugging the transducer
cable assembly into the simulator and checking all the functions with the eleven point rotary switch.
This simple device may avoid the unnecessary removal of the pressure transducer from the machine, thus saving valuable
down time.
SPECIFICATIONS
Accuracy ±0.25%
Full Scale Output Nominal 3mV/V
Configuration 350 ohm Wheatstone bridge
Input Resistance 350 ohm ±0.5%
Output Resistance 350 ohm ±0.5%
Range 0-100% of F.R.O. in 10% steps
Zero Balance ±0.25% of F.R.O.
Excitation 5 – 12V D.C.
Table des matières
Autres manuels Terwin Transducteur
Manuels Transducteur populaires d'autres marques

Mianyang Weibo Electronic
Mianyang Weibo Electronic WB Series Manuel utilisateur

ProMinent
ProMinent Dulcometer DMT Manuel utilisateur

MKS
MKS MicroPirani 925 Series Comment utiliser

WIKA
WIKA WU-20 Manuel utilisateur

Alcatel Vacuum Technology
Alcatel Vacuum Technology BARATRON 622A Manuel utilisateur

Camille Bauer
Camille Bauer SIRAX CH-5610 Manuel utilisateur