Tempest LIZA 6425H Manuel utilisateur

LIZA Enclosure User Manual page 1
Tempest
11845 Wicks Street
Sun Valley, CA 91352, USA
Tel +1 818 787 8984
Fax +1 818 252 7101
www.tempest.org
For the following products,
manufactured after January 2015
LIZA 6425H
LIZA 6450H
LIZA 6475H
In the interest of continuous product improvement, the information in this document is subject to change without
notice. Neither Tempest Lighting, Inc. nor its representatives or agents may be held liable for expense or injury
arising from it.
© Tempest Lighting Inc. All Rights Reserved January 2015
User Manu
al
LIZA Compact Moving Light
Enclosures
User Manuall
LIZA Projector Enclosures

LIZA Enclosure User Manual page 2
Declaration of Conformity
This is to certify that the following products
64xxH LIZA Projector Enclosures
are in Compliance with the following standards or specifications according to the Electro
Magnetic Compatibility Directive 2004/108/EC.
EN55015, Cispr 16
and are in compliance with the following standards or specifications according to the Low
Voltage Directive 2006/95/EC.
EN60598-1
This declaration is made by the manufacturer
Tempest Lighting, Inc.
11845 Wicks Street, Sun Valley, CA 91352, USA
This declaration is based on tests that were conducted on the submitted samples of the above
mentioned products. Detailed results can be referred to test reports C27963_11, C27963_12,
C27963_13, C27963_14
Dated: January 21st, 2015
Signature . . . . . . . . . . . . . .
Tempest Lighting Inc
1 Introduction

LIZA Enclosure User Manual page 3
1 Introduction
Thank you for purchasing the LIZA projector enclosure. It will serve you for many years, protecting
your projector from dust, thieves and vandals, and operating at extremely low sound levels.
Products Covered By this Manual:
LIZA 6425H 90-264VAC, 50/60Hz
LIZA 6450H 90-264VAC, 50/60Hz
LIZA 6475H 90-264VAC, 50/60Hz
Using This Manual
Please read this manual in its entirety before starting work. All the information contained is
important, and should be read carefully before proceeding. Heed all warnings and advisories.
Icon Key:
Valuable information
Electrical Warning
Safety Information

LIZA Enclosure User Manual page 4
2 Installation
2.1 Safety and Warnings
These warnings are for your protection. Failure to comply may result in serious injury or death.
Tempest Lighting, Inc. assumes no responsibility for damages or injury incurred by misuse or
mishandling of product.
Do not attempt to install or operate the enclosure before fully reading and understanding this
manual
Never allow anyone who has not read this manual to open the enclosure or perform
maintenance on the equipment within.
Never leave the enclosure unattended when open.
Always make sure all bolts and latches are tight and safety locks are in place after performing
any form of maintenance on the unit.
Do not open any electrical boxes until power has been shut off to all supply lines to the
enclosure (including the one powering the equipment).
Do not open any outdoor enclosure in wet weather.
2.2 Tools and Equipment
To install the enclosure, you will need the following items:
Crescent wrench
Phillips screwdriver
Terminal screwdriver
Proper wiring installation equipment (for line power and signal wiring)
Any equipment listed in the equipment manufacturer’s equipment-specific installation
directions

LIZA Enclosure User Manual page 5
2.3 Mounting the LIZA Enclosure
The LIZA enclosure must be mounted under a solid structure rated for the weight of the
enclosure and the equipment inside it.
All suspensions over personnel must be approved by the appropriate safety authorities in the
jurisdiction of the installation. Tempest Lighting, Inc., its agents and employees will not be
held responsible for unsafe installation practices by others.
LIZA will generally be installed in three ways:
a) In a suspended ceiling, using the industry-standard GrippleTM hardware supplied
b) Under a hard ceiling or structure, using four M6 or ¼” bolts or dropper rods
c) Suspended from a vertical pole or horizontal pole or truss, using a Tempest XYZ Mount
It is the responsibility of the installer to ensure that all mounting points are secure and conform to local
safety regulations. Tempest Lighting Inc. accepts no responsibility for damage or injury arising from
inappropriate or unsafe installation.

LIZA Enclosure User Manual page 6
Suspended Ceiling
1. Remove ceiling tiles
2. Attach the looped ends of all four Gripple wires around structural members above the
ceiling tiles. If there are no suitable attachment points, you will need to add them, in
accordance with local building codes.
Take the looped end of the Gripple wire and thread it around a structural support in the ceiling, rated
for the weight of the LIZA enclosure and projector.
3. IMPORTANT: In order for the projector to be held securely without movement, the Gripple
wires must attach to hanging points that are OUTSIDE the footprint of the LIZA enclosure,
using an angle 20-30 degrees from vertical.
4. Thread the Gripples onto the four eye bolts on the enclosure base and tighten until the
enclosure is level and its base is touching the ceiling T-bars
5. Do not replace tiles until installation is complete.
20-30˚

LIZA Enclosure User Manual page 7
Hard Ceiling or Superstructure
1. Remove all four eyebolts, lock nuts and washers from the top of the LIZA enclosure
2. Mark out the ceiling/structure for mounting points and air ducts, according to the drawing
below. NOTE: This drawing is the top view.
3. Use the eye bolt holes to attach the LIZA frame to the underside of the ceiling/structure,
using M6 or ¼” bolts or dropper rods (not supplied).

LIZA Enclosure User Manual page 8
Tempest XYZ Mount
There are two types of Tempest XYZ mount, to attach either to a vertical pole or to a horizontal
pipe or stage truss. Either way, the XYZ mount allows precise positioning at any angle, with
adjustment for pan, tilt and roll.
1. Use a hammer and a screwdriver to remove the four ½” knockouts on top of the LIZA base
(see drawing above).
2. Using M12 or ½” hardware, bolt through the LIZA base to the slots on the Tempest XYZ
mount.
3. Hang the XYZ mount in accordance with the instructions supplied with it.
LIZA with Tempest XYZ Truss Mount.
Order Tempest Part # 6500.XYZ.T
LIZA with Tempest XYZ Pole Mount.
Order Tempest Part # 6500.XYZ

LIZA Enclosure User Manual page 9
3 Wiring
3.1 Electrical Preparation
All electrical work must be carried out by a properly licensed electrician. Failure to observe this
point will void the factory warranty for the Tempest Enclosure and possibly the equipment housed
inside.
1Before starting work, switch off power to the branch circuit, carefully following lockout and tag-out
procedures. Failure to do so could cause serious injury or death.
2Two electrical junction boxes will be required within a short distance of the LIZA enclosure for:
AC supply wiring
DMX control wiring
Your LIZA enclosure is supplied fitted with two cable entry points, for Power and signal cables.
The cable entries are suitable for use with standard conduit fittings. US size ½”, international 20mm.
All junction boxes must be installed in accordance with local electrical codes and should be located near the
permanent installation of the enclosure.
The AC supply must be protected by a fuse or circuit breaker of a rating suitable for the equipment.
The user may connect the enclosure and the equipment enclosed to the same switched supply, or run them
separately, according to preference (see below).
Note that for temporary installation, the conduit fittings may be replaced with suitable cable entry glands,
at the user’s discretion.

LIZA Enclosure User Manual page 10
3.2 Remove the Fan Control Cover, and pull AC and Signal control wires through conduit entries, as
shown here.
Power Connections –Single or Split Feed
Single Feed: Enclosure and projector are on the same power circuit. The enclosure will move air in the
event that the enclosure gets warm when the projector is off (recommended). The circuit must be
fused to protect the projector load plus 40W.
Split Feed: Enclosure and projector are on separate power circuits. It is the user’s responsibility to
ensure that the enclosure power is on when the projector is in use. In Split feed operation the LINE
circuit will pull 40W maximum and the SPLIT circuit must be protected to suit the projector load.
Replace the Controller Cover.
LIZA Fan Control
Board
IMPORTANT:
Split Feed –you MUST cut
this link at both ends
Signal Conduit
Entry
Power Conduit
Entry
Duplex IEC C13
Outlet
Line: 90-265VAC
Split Feed (Projector Power) 90-265VAC*
Neutral
Protective Ground/Earth
* Split feed is NOT CONNECTED for
Single Feed operation
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Tempest Projecteur
Manuels Projecteur populaires d'autres marques

Panasonic
Panasonic PTL735NTU - LCD PROJECTOR-NETWORK IB Manuel utilisateur

NEC
NEC NP600S EDU Manuel utilisateur

BenQ
BenQ SH753P Manuel utilisateur

Eiki
Eiki EK-623U series Manuel utilisateur

Epson
Epson PowerLite Pro Cinema 6020UB Manuel utilisateur

Epson
Epson PowerLite Home Cinema 705HD Manuel utilisateur