16
RTR-500 Series - Specications
Remote Unit
Product RTR
-
505-TC/
505-TCL
RTR
-
505-Pt/
505-PtL
RTR
-
505-V /
505-VL
RTR
-
505-mA/
505-mAL
RTR
-
505-P/
505-PL
Measurement Channels Temperature 1ch Temperature 1ch Voltage 1ch 4
-
20mA 1ch Pulse 1ch
Sensor Thermocouple:
Type K, J, T, S
Pt100, Pt1000
(3-wire) - - -
Measurement Units °C, °F °C, °F V, mV mA P
Measurement Range
-
199 to 1700 °C
-
199 to 600 °C 0 to 22 V 0 to 20 mA
(Operational up to 40 mA)
Input Signal:
Non-voltage Contact Input
Voltage Input (0 to 27 V)
Detection Voltage:
Lo: 0.5 V or less
Hi: 2.5 V or less
Input Impedance:
Approx.100 KΩpull up
Chattering Filter:
ON: 15 Hz or less
OFF: 3.5 kHz or less
Maximum Count:
61,439/Recording Interval
Accuracy
Thermocouple Measurement
±0.3 °C + 0.3 % of reading
(Type K, J, T)
±1°C + 0.3 % of reading
(Type S)
Cold Junction Compensation
±0.3 °C (10 to 40 °C)
±0.5 °C (
-
40 to 10 °C / 40 to
80 °C)
±0.3 °C + 0.3 % of reading
(10 to 40 °C)
±0.5°C + 0.3 % of reading
(
-
40 to 10 °C / 40 to 80 °C)
±0.5 mV + 0.3 % of reading
(10 to 40 °C)
±1 mV + 0.5 % of reading
(
-
40 to 10 °C / 40 to 80 °C)
±0.05 mA + 0.3 % of reading
(10 to 40 °C)
±0.1mA + 0.3 % of reading
(
-
40 to 10 °C / 40 to 80 °C)
Note: The above mentioned temperature is the operating environment for Input Module only.
Measurement Resolution Type K, J, T : 0.1 °C
Type S: approx. 0.2 °C 0.1 °C
Up to 400 mV : 0.1 mV,
Up to 800 mV : 0.2 mV,
Up to 999 mV : 0.4 mV,
Up to 3.2 V : 1 mV,
Up to 6.5 V : 2 mV,
Up to 9.999 V : 4 mV,
Up to 22 V : 10 mV
0.01 mA
Logging Capacity 16,000 readings
Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode (*1) Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full)
LCD Display Items Measurements, Battery Life Warning, etc.
Communication Interfaces
Wireless Communication (Short Range Radio Communication)
FCC Part15 Section247 / IC RSS
-
210 (Frequency Range: 902 to 928 MHz, RF Power: 7 mW)
ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5 mW)
Optical Communication (proprietary protocol)
Wireless Transmission
Range Approx. 150 meters (500 ft) if direct and unobstructed
Power Lithium Battery: LS14250 (*2) or CR2 (*3) x 1 L Type: Large Capacity Battery Adaptor Kit (RTR
-
500B1) (*4)
External Power Adaptor Kit (RTR
-
500A1: sold separately)
Battery Life (*5)About 10 months
L Type: About 4 years
Dimensions
H 62 mm x W 47 mm x D 19 mm
L type: H 62 mm x W 47 mm x D 46.5 mm
(excluding protrusions and Input Module)
Antenna length: 24 mm
Weight
Approx. 56 g
L Type: approx. 109 g
(including battery / excluding Input Module)
Operating Environment
-
30 to 80 °C
(The environmental operating range of the logger unit is
-
40 to 80 °C, but wireless communications cannot be utilized in an environment less than
-
30 °C.)
Waterproof Capacity (*6) IP64: Splash proof (rated for use in daily life) Note: Input Module is not water resistant.
Accessories
Input Module
(TCM
-
3010)
Input Module
(PTM
-
3010)
Input Module
(VIM
-
3010)
Input Module
(AIM
-
3010)
Input Module
(PIC
-
3150)
Tubed Lithium Battery (LS14250) or Large Capacity Battery Adaptor Kit (RTR
-
500B1), Strap, User's Manual (Warranty Included)
Compatible Base Units RTR
-
500, RTR
-
500NW/500AW, RTR
-
500DC, RTR
-
500GSM RTR
-
500, RTR
-
500NW/500AW, RTR
-
500DC
*1: Only "Endless" is available when using RTR
-
500W for Windows or RTR
-
500GSM for Windows.
*2: The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set for low-temperature use (TR
-
11P2) for replacement.
*3: Only use the CR2 within temperature range of - 20 to 60°C, avoiding exposing the CR2 to excessive vibration such as transportation.
*4: When using RTR
-
500B1 it is necessary to purchase Lithium Battery (LS26500). For details, contact your local authorized distributor.
*5: Battery life varies depending upon the ambient temperature in which it is used, the recording interval, the frequency of communication, and the battery performance. All estimates are based on
operations carried out with a new battery and are in no way a guarantee of actual battery life.
*6: This is the waterproof capacity of the data logger with the Input Module connected.
The specications listed above are subject to change without notice.