Synergy Global Technology RAC141 Manuel utilisateur

EnhanceRAID R4 User Manual
RAC141
ULTRA 320 SCSI to SATA
Disk Subsystem
User Manual
Version 1.0 (Oct. 2006)
www.RackmountMart.com

Enhance |Technology, Inc.
EnhanceRAID R4 User Manual
Preface
About this Manual
This manual is designed and written for users of the RAC141 . Users
should ideally be familiar and have some experience with RAID planning and
data storage operations. However, this manual will provide instructions and
education for those who have little or no experience in RAID to install and setup
the RAC141 .
Notice
Product features and specifications described in this manual are subject to
change without notice.
The manufacturer shall not be liable for any damage, or for the loss of
information resulting from the performance or use of the information contained
herein.
All rights reserved.
EnhanceRAID R4 User Manual
www.RackmountMart.com
Thank you for using
Synergy Global Technology Inc.
products; if you have
any question, please e-mail to
. We will answer
your question as soon as possible.
Copyright@2008,Synergy Global Technology Inc.

Enhance |
EnhanceRAID R4 User Manual
Table of Contents
Chapter 1 Product Overview .......................................................... 5
1.1 Features........................................................................... 5
1.2 Specifications................................................................... 6
Chapter 2 Environment Setup........................................................ 7
2.1 Before installation ............................................................ 7
2.2 Product overview ............................................................. 9
2.3 Install SATA disks............................................................ 9
2.4 Connect cables.............................................................. 10
Chapter 3 GUI Connection
10
3.1 GUI – http....................................................................... 11
3.2 RS-232 serial port.......................................................... 11
3.3 Remote control – secure shell ....................................... 11
3.4 LCM ............................................................................... 12
Chapter 4 GUI operation ............................................................... 13
4.1 RAC141 Menu................................................................ 13
4.2 Login.............................................................................. 14
4.3 Quick install.................................................................... 15
4.4 System config ................................................................ 16
4.4.1 IP address................................................................17
4.4.2 Password................................................................. 17
4.4.3 Date.........................................................................17
4.4.4 Mail..........................................................................18
4.4.5 SNMP ......................................................................18
4.4.6 Event log.................................................................. 19
4.5 Volume config................................................................ 19
4.5.1 Physical disk............................................................ 20
4.5.2 Volume group ..........................................................22
4.5.3 User data group....................................................... 23
4.5.4 Cache volume..........................................................25
4.5.5 Logical unit...............................................................26
4.6 Enclosure management................................................. 27
4.6.1 SAF-TE config .........................................................27
4.6.2 Voltage & Temperature............................................27
4.6.3 SMART....................................................................28
4.7 Maintenance .................................................................. 28
4.7.1 Upgrade...................................................................29
EnhanceRAID R4 User Manual
www.RackmountMart.com

Enhance |Technology, Inc.
EnhanceRAID R4 User Manual
4.7.2 Info...........................................................................29
4.7.3 Shutdown................................................................. 30
4.8 Logout............................................................................ 30
Chapter 5 Advanced operation .................................................... 31
5.1 Create volume group ..................................................... 31
5.2 Create user data volume................................................ 32
5.3 Attach and detach Bus ID, SCSI ID, and LUN............... 33
5.3.1 Attach LUN to UDV..................................................33
5.3.2 Detach Bus ID, SCSI ID and LUN from UDV........... 34
5.4 Create dedicated cache................................................. 35
5.5 Set global spare and dedicated spare disks .................. 36
5.6 Migration / Expansion .................................................... 37
5.7 Snapshot........................................................................ 38
5.8 Auto snapshot................................................................ 39
Chapter 6 Formatting and Partitioning the R4……….....43
6.1 Windows Users…………………………………………………..43
6.2Formatting drive over 2TB capacity on Windows Vista………46
Appendix 48
A.1 Glossary......................................................................... 46
A.2 RAID Explained.............................................................. 48
EnhanceRAID R4 User Manual
www.RackmountMart.com

Enhance
- 5 -
Chapter 1 Product Overview
1.1 Features
RAC 141 Subsystem is a high-performance RAID subsystem built
around EnhanceRAID controller with the features listed below:
•Single channel performance is over 240MB/sec
•Snapshot-on-the-box without relying on host software
•SATA II drive interface (Backward-compatible)
•Configurable N-way mirror for high data protection
•On-line volume expansion with no system down-time
•Extensible APIs for host server integration
When properly configured, RAC 141 provides non-stop data storage
service with a high degree of fault tolerance through the use of RAID technology
and advanced array management features.
RAC 141 connects to the host system through an U320 SCSI interface
for optimized performance in speed. It can be configured to any RAID level to
provide the most reliable data protection and fastest data transfer rates as
required by user applications.
RAC 141 is designed with a new level of polynomial technology to
implement the RAID 6 function. RAID 6 arrays allow up to two simultaneous HDD
failures without impact on the existing data, making the RAC 141 the
most reliable RAID system.
RAC 141 has SNAPSHOT feature that can perform an online speedy
logical data backup on the controller level without affecting the performance of
the server host.
RAC 141 offers array migration and expansion technology to give users
the flexibility to change RAID levels and increase array capacity for increased
performance or data security to meet the changing demands of applications.
RAC 141 is the most cost-effective disk array subsystem with
completely integrated high-performance and data-protection capabilities that
meet or exceed the highest industry standards.
EnhanceRAID R4 User Manual
www.RackmountMart.com

Enhance |Technology, Inc.
EnhanceRAID R4 User Manual - 6 -
1.2 Specifications
Model Specifications
RAID Engine EnhanceRAID 320
Storage Processor Intel IOP80331 500Mhz
Hybrid Technology SCSI to SATA
Supported RAID Levels 0, 1, 0+1, 3, 5, 6 & JBOD
Memory 256MB DDR333 DIMM (Max. up to 1GB)
Max. HDD Supported 4 x SATA I/II HDDs
Max. HDD Capacity 750GB
Max. System Capacity up to 4.0TB
Host Connection 1- Ultra320 SCSI Port
Host Connection 2- Multi-lane Port
Remote management via 1-Ethernet Port
RAID management Web browser & SNMP
OS Independent & Transparent Yes
Enclosure Specification
Hot-Swappability 4 x Removable HDD Tray
Drive Failure LED indicator for each HDD
System Fan 4 x 4cm fan (Middle)
Power Supply Single PS2 150Watt
Temperature built-in thermal & fan sensor
Dimensions(H x W x D) 31 " x 24 " x 7.5"
Weight (without disk) 30 Lbs
Power Supply (150W)
Input Range 100 to 240 VAC. 10%
Voltage +5V/25A +12V/10A 47-63Hz
Agency Approval EMI/RFI, CE, FCC B, BSMI
Safety UL, CUL, CB, TUV, CCC
Physical & Environment
Operating Temperature 0°C ~ 40°C
Non-Operating Temperature -10°C ~ 50°C
Relative Humidity 5% to 95% non-condensing
Supported Operating System
Windows 95, 98/98SE, NT, 2000, Millennium, XP, 2003
Mac 9.1 and above, including OSX, OSX Server, XSERVE
Mac 8.6-9.04 support possible with ATTO SCSI HBA.
Linux (all latest builds) which support SCSI.
And all other systems supporting SCSI protocol
Optional Features
•Snapshot on the Box
•N-Way Mirror
•Battery Backup
•System Handle
Manufacturer Warranty
System Warranty 3 Years
Advanced Replacement 90 Days
EnhanceRAID R4 User Manual
www.RackmountMart.com

Enhance |
EnhanceRAID R4 User Manual
Chapter 2 Environment Setup
2.1 Before installation
Requirement:
Prepare a host system with a SCSI HBA card. For optimized performance, a
SCSI Ultra 320 HBA is recommended. The host system should have one free
COM port to be used for the initial setup. The management and configuration
web GUI can be accessed remotely after proper setup.
Package contents
•1 pcs 4x3.5'' SATA-II HDDs Rackmount RAID Storage Enclosure
•4 pcs Hot-Swap Removable HDD Tray (Installed)
•4 pcs Cooling Fan Module (Installed)
•One 150 Watt Power Supply (Installed)
•One SCSI Cable and One SCSI Terminator
•Heavy Duty Foam Protection
•Accessory Box:
oScrews for Mounting Hard Drives
oOne Standard Power Cord
R4 Rackmount RAID Storage
Enclosure 4 pcs Hot-Swap Removable HDD Tray Accessory Box
(Screws, Power Cord)
SCSI Cable and Terminator Heavy Duty Foam Protection
EnhanceRAID R4 User Manual
www.RackmountMart.com

Enhance |Technology, Inc.
EnhanceRAID R4 User Manual - 8 -
Optional Items
Model Number:
AC-ETR-TRAY
Description:
Additional Hot-Swap Removable HDD Tray
Model Number:
Upgrade-MT512
Description:
Memory upgrade from 256MB to 512MB
Model Number:
Upgrade-MT1G
Description:
Memory upgrade from 512MB to 1G
Caution
•Before starting any type of hardware installation, please ensure that all
power switches have been turned off and all power cords have
been disconnected to prevent personal injury and damage to the
hardware.
To avoid overheating, RAC 141 should be operated in a well-
ventilated area and in such a way that sufficient airflow is
maintained across the controller chips.
•Static electricity can damage electronic components. To guard against
such damage:
1. Work in a static-free environment
2. Wear a grounded anti-static wrist strap
3. Store uninstalled components in anti-static bags
4. Handle PCBs by their edges and avoid touching chips and
connectors.
•Environmental requirements:
Temperature: 0°C to 40°C (32°F to 104°F)
Humidity: 5% to 95%, non-condensing
EnhanceRAID R4 User Manual
www.RackmountMart.com

Enhance |
EnhanceRAID R4 User Manual - 9 -
2.2 Product overview
Front view
Figure 2.2.1
Rear view
Figure 2.2.2
2.3 Install SATA disks
If the hard drives do not come with the RAID system, please follow the
instructions for installation below.
•Press the release button and pull the handle to remove the disk tray. The
trays may have to be unlocked first using the key provided. (Figure 2.3.1,
Figure 2.3.2)
•Insert the disk into the disk tray with the connectors directed toward the open
rear of the tray.
Access LED
Power LED
Release
EnhanceRAID R4 User Manual
www.RackmountMart.com
Table des matières
Autres manuels Synergy Global Technology Matériel informatique
Manuels Matériel informatique populaires d'autres marques

EMC2
EMC2 VNX Series Manuel du propriétaire

Panasonic
Panasonic DV0PM20105 Manuel utilisateur

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 Manuel utilisateur

Gigabyte
Gigabyte B660M DS3H AX DDR4 Manuel utilisateur

Raidon
Raidon iT2300 Manuel utilisateur

National Instruments