Stuv P-10 Manuel

164981 > ...P-10
EN
To give to the user
Directions
for use
Please see our website for more
information: www.stuv.com
Find us also on:
June 2015

WELCOME TO THE WORLD OF STÛV!
You have just opted for an eco-friendly, high-performance heating system.
We hope that you enjoy using it from this moment on.
You will find advice and instructions for the use and maintenance of your Stûv in this document.

CONTENTS
PRESENTATION OF THE PRODUCT 4
Standards, certification and technical characteristics 4
Stûv P-10 marking 5
Materials and main components 5
Dimensions 6
Overview of the stove components 7
How does your Stûv P10 work? 8
Fuel 9
USE 10
General recommendations 10
Environment 10
Recommendations before first use 11
Initial cautions 12
Basic usage 12
Managing the remote control 13
Description of the remote control menu 14
Lighting the Stûv P-10 18
2 usage modes: manual mode vs. calendar mode 19
Using manual mode 19
Using calendar mode 20
Configuring calendar mode 21
Shutting down the Stûv P-10 23
MAINTENANCE 24
Daily maintenance 24
Weekly maintenance 25
Annual maintenance 28
Annual maintenance 29
IN CASE OF PROBLEMS... 30
Alarm signals 30
THE EXTENSION OF THE STÛV GUARANTEE : A SIMPLE PROCEDURE FOR MORE PEACE OF MIND. 36
GUARANTEE FORM 37
CONTACTS 39

4SN 164981 - ...
Stûv P-10 - directions for use [en] - 08/15
Standards, certification and technical characteristics
PRESENTATION OF THE PRODUCT
The Stûv P-10 stove (for intermittent
operation) comply with the
requirements of EN European
Standards in terms of efficiency,
gas emissions, safety etc….
Data provided in this notice are
supplied by a certified laboratory.
Results of tests according
to EN 14785 standards: 2006
Domestic wood pellet convection
heating appliances
Stûv P-10s are covered by:
patent nos.:
EP 2304319
JP 5390603
US 8.904.944
US 8.826.899
+ Patents pending
model drawing nos.:
DM/72417
DM/72418
002500942-0001
002500942-0002
Stûv P-10
System mass 175 kg
Nominal heat power: 8 Kw
Heat output at reduced speed 2.4 Kw
Minimum diameter of the duct for the intake of outside combustion air
(if the stove is not connected to outside air) 30 cm2
Efficiency at rated power 90.5 %
Performance at reduced power 94.5 %
Average smoke temperature at rated power, at the output of the appliance 217 °C
Average smoke temperature at reduced power, at the output of the appliance 94 °C
Minimum safety distance from adjacent combustible materials :
> behind (from the bottom)
> on the sides
> below
> above
7 cm
10 cm
0 cm
10 cm
CO emissions at rated power 0.001 %
CO emission at reduced power 0.028 %
Particle emissions (at rated power) 5 mg/Nm3
Weight-flow ratio of smokes (at rated power) 5.1 g/s
Mass flow of smoke at reduced power 2.8 g/s
Recommended draught at maximum power 6 Pa
Recommended draught at minimum power 3 Pa
Minimum draught at the output of the appliance for flue calculation. 0 Pa

5
SN 164981 - ...
Stûv P-10 - directions for use [en] - 08/15
Standards, certification and technical specifications (continued)
Requirements relating to the electrical power supply
Voltage 230 V
Frequency 50 Hz
Electric power consumption on ignition 1000 W
Electrical power consumption under normal operation 40 W
Requirements relating to fuel
Recommended fuel Wood pellets only
Certification Din plus, EN plus A1
Diameter 6 mm
Materials and main components
The Stûv P-10 consists mainly of:
> Painted steel sheets/tubes for
structural and facing elements
> The bottom facings are available in
a oak-veneered wood panel finish
(light or dark)
> Vermiculite for the inside of the
combustion chamber
> Cast steel for the structural elements
of the burner
> Aluminium for the smoke extraction
flue
> HDPE for the Pellet hopper
> A trim finishing kit is available to
trim the bottom facings. In this case,
the installer should check that the
material chosen corresponds to the
use for which it is intended.
All of these components are
deemed to be compliant within
tolerances and national practices.
Stûv P-10 marking
Stûv S.A Rue Jules Borbouse 4, 5170 Bois-de-Villers
15
Notifi ed Body 1881
Declaration of performance number : 15QA151478501
EN 14785 : 2006
Stûv P-10
Read and follow operating instructions
Use only recommended fuel :
Wood pellets diameter 6 mm, quality standard EN plus A1
Version française disponible dans la notice d’utilisation
Nederlandse versie beschikbaar in de gebruikersgids
Deutsche Version in der Installationsanleitung
La versione italiana è disponibile all’interno della guida utente
Versión española disponible en el manual del usuario
Versão portuguesa disponível no Manual do Utilizador
Česká verze je k dispozici v uživatelské příručce
Wersja polska dostępna w instrukcji obsługi
Heating output nominal
nominal
nominal
nominal
peak
reardr
ηnom
8.0kWPnom
COnom
Tnom
0.001%
217°
90.5%
1000W
230V
70mm
2.4kWPpart
COpart
Tpart
0.028%
94°
94.5%
40W
50Hz
100mm
1000mm
reduced
reduced
reduced
reduced
average
sidesds
ηpart
frontdf
Measured CO
(at 13% oxygen content)
Average temperature of the
smoke at the appliance’s
outlet
Minimum clearance distance
from combustible materials
Turntable appliance : 1000 mm
in range of inspection window
Appliance effi ciency
Rated input power
Rated voltage
Rated frequency
Stûv has a determinedly proactive
responsible environmental apprach.
We think about the end-of-life of our
products.
Each of the device's components can
be isolated so that sorting can be
carried out and therefore optimum
recycling.
Removal of the various parts must
be done in accordance with local and
national regulations.

6SN 164981 - ...
Stûv P-10 - directions for use [en] - 08/15
Dimensions
wood and “to be
trimmed” version
wood and “to be
trimmed” version
sheet metal version
sheet metal version
480
1400
120
120 445367
80
60
448
55
70
565 240
480
114
Ø 60
Ø 60
Ø 80
251
140
17
100
115
370
760
400 340
400
480

7
SN 164981 - ...
A
H1
H2
I
J2.2
J2.1
J1.1
J1.2
K
L
M
R
Q
O
ST
U
V
P
N2
N1
C1
C2
D
E
F
B
G
Stûv P-10 - directions for use [en] - 08/15
Overview of the stove components
A. Lantern
B. Lantern frame
C.
C1. Right-hand lantern facing
C2. Left-hand lantern facing
D. Top shelf
E. Vermiculite Ring
F. Flame modeller
G. Lantern door
H.
H1. Rear shelf
H2. Front shelf
I. Collar
J.
J.1.1 Right facing (metal panel
version)
J.1.2 Right facing (wood and to be
trimmed version)
J.2.1 Left facing (metal panel
version)
J.2.2 Right facing (wood and to be
trimmed version)
K. Bottom door
L. Grilles
M. Burner casting
N.
N1. Archimedes screw 1
N2. Archimedes screw 2
O. Rear metal panel
P. Smoke flue
Q. Fan body
R. Pellet hopper
S. Electronic card
T. Ashpan
U. Reloading hatch
V. Front cover
*Facings are available in two versions.
The illustration shows one side of each
finish.

8SN 164981 - ...
Stûv P-10 - directions for use [en] - 08/15
How does your Stûv P10 work?
The Stûv P-10 is a wood pellet stove
consisting of two major parts:
- A base containing the pellet hopper,
the fuel and combustion feed, smoke
extraction and all the electronics and
sensors enabling the operation of
the appliance to be adjusted and set
[diagram 1].
- A pivoting lantern where the burning
of the pellets takes place. This top part
also radiates and diffuses convection
heat; it is fitted with a window which
gives a view of a beautiful large flame
[diagram 2].
The device has an electronic
management system operating on
two variables to provide optimal
thermal comfort. Depending on the
user’s requirements, the Stûv P-10 will
adjust its output and maintain this by
adjusting:
- The quantity of pellets burned
[diagram 3]
- The quantity of air supplied to
combustion [diagram 4]
1
3
2
4

9
SN 164981 - ...
Stûv P-10 - directions for use [en] - 08/15
Fuel
What are wood pellets?
Wood pellets are a solid and eco-
friendly fuel made from sawmill
waste. Sawdust is compressed without
glue or binder so as to obtain a
standardised cylinder with a high
density and low moisture. These
characteristics give the granules
significant calorific power.
Which pellet should I choose?
The Stûv P10’s performance may vary
depending on the pellets used.
For correct use, the pellets must
comply with ENplus or DINplus A1
certifications. These references ensure
that the pellets have the following
features:
- diameter: 6 mm
- min-max length: 3 - 40 mm
- moisture content: ≤ 10 %
- ash content: ≤ 7%
Pellet storage
Pellets must be stored in a dry
place where the temperature is
above 5 °C.
They can be stored in bags or in
bulk but avoid storage in the open
air.
Caution!
Take care not to crush the bags to
avoid producing too much dust.
Avoid emptying dust into the
machine’s hopper as this sawdust
can disrupt the feed system.
If you use pellets stored in a bag,
after opening the bag, use the
contents within a relatively short
time. Otherwise there is a risk of
the pellets getting damp.
Do not burn any liquid or solid
other than pellets that meet the
UNI EN 14961-2 standard!

10 SN 164981 - ...
7cm 10cm
100cm
1
Stûv P-10 - directions for use [en] - 08/15
USE
General recommendations
Important!
This stove should have been installed
in accordance with good practice
guidelines and local and national
regulations. A qualified professional
should have ensured that the
characteristics of the smoke flue and
the surroundings are suitable for the
stove installed.
Read this user guide carefully
and follow the maintenance
recommendations.
Complete and return the guarantee
certificate (at the end of this
document) to us.
Use
The stove should be used in
accordance with local and national
regulations and European standards.
Some parts of the stove – the glass
door and the outside walls – may
become very hot even during normal
usage (rated power) and significant
heat may be radiated from the glass
door.
In order to prevent any damage or
risk of fire, when the stove is in use,
remove all heat-sensitive objects from
the radiation area. Take particular care
when you leave the room.
Ensure that the glazed part is
not facing any materials that are
heat-sensitive.
Do not leave young children without
supervision in the room where the
stove is installed.
Ensure the air inlets and outlets are
always kept clear.
Caution!
The appliance is not designed to be
used with cooking utensils. Do not
place anything on the appliance or on
the facings.
Repairs / Maintenance
Any modification carried out to the
system may cause danger and will
invalidate your guarantee. Only use
Stûv spare parts in the case of repairs.
Should a fire in the flue get out of
control
Do not open the stove's door during
the initial period.
Disconnect the device.
Call the fire brigade.
If the fire has not died down after
a few minutes, use a dry powder,
soda acid or sand extinguisher (never
water).
After a chimney fire, ventilate the
room where the stove is situated.
Have the chimney cleaned and
inspected by a professional. Have
repairs carried out if necessary.
Every Stűv P-10 is subjected to a factory check.
There may be traces of combustion or light residues after this test.
The heat radiated from the glass door
and the walls may be significant.
Whichever way the stove is pointing,
observe the safety distances with
regard to combustible materials
[diagram 1], or ensure that the
materials exposed to radiated heat are
resistant to hight temperatures.
Environment
Autres manuels pour P-10
3
Table des matières
Autres manuels Stuv Poêle

Stuv
Stuv 30-in Mode d’emploi

Stuv
Stuv 30 Compact Manuel utilisateur

Stuv
Stuv 15 Manuel

Stuv
Stuv 16/58-cube Guide de l'utilisateur

Stuv
Stuv 30 Compact Manuel

Stuv
Stuv 21 Series Manuel utilisateur

Stuv
Stuv Micromega Manuel utilisateur

Stuv
Stuv 16/58-cube Manuel utilisateur

Stuv
Stuv 16-up Manuel utilisateur

Stuv
Stuv 6-IN Manuel utilisateur
Manuels Poêle populaires d'autres marques

Vermont Castings
Vermont Castings Intrepid 2 Manuel utilisateur

Italiana Camini
Italiana Camini CLASSICA Guide de démarrage rapide

Avalon
Avalon Vashon Avanti DVS FS Manuel utilisateur

Spartherm
Spartherm ambiente a1 Manuel utilisateur

Dimplex
Dimplex MCFSTV12AU Manuel utilisateur

Warmlite
Warmlite WL46040 Manuel utilisateur




















