2Status Pro – µLevel User Guide
User Guide – English
Level ystem (BG 840100)
We would like to congratulate you on the purchase of your Status Pro µLevel Precision
Level System. Before initial usage you should carefully read the safety instructions as well
as the user guidelines contained in this manual. We wish you every success when using
this Measurement Instrument. Please note: User Manuals can be amended when improve-
ments or changes to the product range have been carried out.
Use the link below to make sure you have the most up to date
version of your User Manual: www.statuspro.com.
The System i cludes the followi g:
• 1 x BT 840100 µLevel single
• 1 x BT 840110 Case for µLevel
• 1 x BT 840120 Foam inlay for µLevel Case
• 1 x BT 840170 Optional: Software Smartlevel Pro + Cable Kit
Please make sure that your system is complete
and all components are in good condition.
Content
1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2. NOTES ON SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 Declaration of confomity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2 Advice on batteries / rechargeable cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.3 Instrument care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.4 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

3
CONTENT
Status Pro – µLevel User Guide
2.5 Liability Exclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3. GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1 Batteries / rechargeable cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.2 Button panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.3 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4. OPERATION GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.1 Temperature Constant before Using . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.2 The Meaning of the Readings Displayed at Measuring Mode . . . . . . . . . . . . . . . . . 12
4.3 Level Inspection and Adjustment for Working Surface . . . . . . . . . . . . . . . . . . . . . . . 13
4.4 Straightness and Flatness Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.5 Use the Store Function of the Level Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.6 Measurement Connecting with Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5. ADJUSTMENT OF THE APPARATUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.1 Relative Zero Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.2 Absolute Zero Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.3 Scale of the Apparatus Displayed Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.4 Renew the Leave Factory Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6. TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7. LEVEL ANDROID SOFTWARE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
7.1 Software Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
7.2 µLevel registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
7.3 Differential (Delta)- and Rightangles- resultant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7.4 Disconnect and exit the app . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
. SMARTLEVEL PRO SOFTWARE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
8.1 Basic Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
8.2 Program Operating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
8.3 Measuring icon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
8.4 Measuring object . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
9. PRODUCTS UND SERVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

4Status Pro – µLevel User Guide
INTRODUCTION
1. Introduction
µLevel is produced in Far East with the quality standard ISO 9001 since 1993. It is a high
accuracy measuring product adopting sensitive capacitance sensor, as well as using
SCM as controller. It is widely used for the inspection of the flatness, straightness of
products, installation and adjustment of precision machine tools, Machining Centers,
Three Coordinates Measuring Machines. Meanwhile its measured data could be input
computer directly, cooperating with measuring software, the flatness and straightness of
products could be measured automatically, and calculated measuring result and graph
could be output and printed. Ergonomical Design, self-contained functions, will bring your
measur-ing work beat all surprise and kilter.
As this Digital Level Meter has a lot of functions, carefulness reading of the operation
manual before using could guide you making full use of the various functions.
2. Notes on safety
2.1 Declaration of conformity
This product conforms tot he EMC Directive 2004/I08/EC and of the, 73/23/EC of CE
Directive.
Instrument Type: level measuring Instrument
The radio Emissions correspond to part 15 of the FCC Directive.
Health and safety:
–EN 50371:2002
–EN 60950-1:2006 + A11:2009 + A1:2010 (EN 60950-1:2011-01)
and/or IEC 60950-1:2005 (2nd Edition) + A1:2009

5
NOTE ON AFETY
Status Pro – µLevel User Guide
2.2 Advice on batteries / rechargeable cells
If the equipment is being stored for a longer period of time or being powered using Mains,
then the batteries/rechargeable cells should be removed to prevent damage of the
instrument through leakage.
When using rechargeable cells always observe the specific charging procedures for the
cells.
Rechargeable cells can be recharged around 1000times when treated correctly, but there
is no guarantee!
2.3 Instrument care
Your measurement instrument is designed for use in an industrial environment and can
withstand water splashes or light spray as well as dust. Clean the equipment using a soft
cotton cloth and a mild soap solution. Laser apertures as well as well as sensor areas
should only be cleaned using a soft, dry and dust-free cloth. Do not use paper towels to
clean glass surfaces as they could scratch. Avoid contact with grease, oil or oil-based
solutions when handling the equipment.
Caution!
Do not try to recharge normal batteries. Do not expose batteries
or rechargeable cells to fire or excess heat (Danger of explosion).
Do not mix batteries and rechargeable cells.
Always use batteries and cells of the same kind.
Do not mix old and new batteries or cells.
Note
Help to protect the environment! Empty batteries do not belong in
the household waste disposal system. Only deposit empty or
damaged cells at a collection point specially designed for this
purpose.

6Status Pro – µLevel User Guide
NOTE ON AFETY
2.4 Calibration
To guarantee measurement accuracy, and reliable operation of your Status Pro
Measurement System, it is of utmost importance that the recommended service intervals
be adhered to. The System should be checked for serviceability, and re-calibrated by the
Status Pro workshops every 12 months.
Within the scope of the service checks, the complete system will also be examined for
possible wear or damage, as well as receiving any software updates.
The date of the next service check for your equipment is stamped on the Status Pro cali-
bration sticker.
To ensure trouble-free processing of the service and calibration checks, simply fill in the
form you will find using the following link www.statuspro.com.
2.5 Liability Exclusion
The Status Pro GmbH does not accept responsibility for damage incurred through incor-
rect use or handling of the equipment. To ensure correct usage, a founded knowledge of
the equipment is essential. It is of the utmost importance that you read and understand
the Handbook!
No responsibility will be accepted for damage incurred through ignorance or disregarding
of the operating instructions.
Advice
To be able to identify the equipment when seeking advice always
quote the serial number of the equipment. The Manufacturer does
not accept any responsibility for damage incurred through incorrect
maintenance carried out by non-authorised personnel.

7
GETTING TARTED
Status Pro – µLevel User Guide
3. Getting started
3.1 Batteries / rechargeable cells
1. Open the cover of the battery storehouse under the handle.
2. Put in 4 pieces of “AA”5# battery as per the positive and negative
poles marked on the cover of the battery storehouse.
3. Close the cover and check the battery installation have been OK.
Remi di g:
• When begin to blinking, all of the batteries should be replaced.
• New batteries could not be mixing used with old batteries.
• If the apparatus will not be used for a long time, the batteries
should be taken out in case of the leakage of the batteries rust
other components, which may cause the apparatus can not work.
• New batteries could not be mixing used with old batteries.
3.2 Button panel
Induction Control Panel
Display
Handle
Power on-off
Data transmission socket
Storehouse for batteries
Measuring base
Housing
SCL / RST key
Control box

8Status Pro – µLevel User Guide
3.3 Display
Start-up I spectio :
Switch on the power, displayer will show measuring phase position. The measuring
unit will be same as what it was before the apparatus being switched off.
Display for measuring unit in mm Display for measuring unit in inch
Measurement with 1µm/m resolution
Measurement with 10µm/m resolution
Zero Setting
Voltage
Temperature
Read stored data
Delete stored data
Scale
Restoration
Serial number
Serial number for current data
The last data stored
Display of measurement readings
Power low
Tilt direction display: right side high
Tilt direction display: left side high
Minus display
Radix point
Measuring unit: second
GETTING TARTED

9
Status Pro – µLevel User Guide
Touch gently the Mode key and adjust it to volt-
age , the LED displayer will show current voltage.
If the voltage is lower than 4 V, Low Voltage warning
will flash.
Reminding
➜If no shows or show abnormally after the power being switched on, please switch off
the power at once. After eliminate the trouble, start-up could be done.
Touching Key
After the apparatus is switched on, touch gently Mode key or , the
LED displayer will show the following list: II, I, Zero Setting, Voltage,
Temperature, Reading, Delete.
Fine adjustment, zero setting; reading, reset (see Function Choice).
Touch the button, radian unit (mm/m) and angle unit (second) could be
transformed. This function could only be available at measuring phase and
, no use at other measuring phase.
(1) When choose radian unit to measure, it display the measuring unit “mm/m”.
It expresses the gradient height difference at length of 1 meter. In the practice
inspection, as the span of the used stride bridge is different, the reading a´Ifor every
inspected point at the E-level meter could be transformed to line value ai(µm) by the
following formula
ai= 1000TL a´I(µm)
T ------ Resolution of the E-level meter (µm)
L ------ Span of stride bridge (mm)
(2) When choose angle unit to measure, LED will show the angle value (˝).
GETTING TARTED

Function Choice
After the apparatus is switched on, touch gently Mode key or could choose
different functions.
Measuring Phase
This is a high precision measuring phase. The resolution of measur-
ing phase II of WL11 Digital Level Meter is 0.001mm/m, suit to
inspect the flatness, straightness of products with precision grade “00”. The resolution of
measuring phase II of WL10 Digital Level Meter is 0.005mm/m, suit to inspect the flatness,
straightness of products with precision grade “0”.
Measuring Phase
This is relative lower precision measuring phase. The resolution of
measuring phase I of WL11, WL10, WL9 Digital Level Meter is
0.01mm/m, suit to inspect the flatness, straightness of products with
precision grade“1”.
Reminding
➜Different resolutions of different measuring phase suit to different accuracy
inspections. Please choose proper product and measuring phase accordingly.
➜The higher measuring phase limit the temperature and environment strictly.
If environment and temperature could not be ensured as requested, the apparatus may
be not stabilized.
Zero Setting
Being at this mode, press button and , the Level Meter
zero position could be set.
(1) At the working surface being inspected, set Zero at any position (relative zero position).
(2) Absolute zero setting
(3) Nice zero setting could be available by pressing the number descending or ascending.
Reminding
➜Regarding to the detailed process of zero setting for Digital Level Meter, please read
Segment “Apparatus Adjustment” on page 16.
Voltage
Function of measuring the power voltage automatically. LED
displayer shows the voltage (V) of the batteries being in use. When
the voltage is lower than 4V, low voltage warning will flash.
10 Status Pro – µLevel User Guide
GETTING TARTED
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Status Pro Instrument de mesure
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur