Battery exchange in BSF7 and BSF8 stations
V1.1 22.09.2015
Writing new battery parameters to the station
To write the battery change date and to reset the consumption counter in the station, you need to
enable the service mode in Config+. You can use the shortcut on your Desktop to do this.
1. Right click on the shortcut and bring up the
properties dialog.
2. In the text box “Target:” scroll to the most right
position and
append a “ --service” after the last quote
character.
3. The last few characters should look like this:
\SPORTident.ConfigPlus.exe" --service.
4. Confirm the changes with OK.
Now start up Config+ by clicking on the Desktop icon.
1. First select your device connection
and choose direct or remote
depending on which device battery
to have changed.
2. Read/verify the device settings and
correct if required.
3. In the menu “Service” select the
sub menu “New device battery…”.
4. In the upcoming dialog select the
desired parameters.
Usually you want to change the
usage counter and the battery
date.
5. Click OK to apply the settings.
Battery lithium 2000 mAh / AA (BSF7), lithium batteries will be
shipped in the original packaging unit of 30 pieces
Battery lithium 1000 mAh / 1/2 AA(BSF8), lithium batteries will be
shipped in the original packaging unit of 30 pieces
Flexible O-ring seals BS8 (1 piece each)
Liquid Silicone (60 ml for approx. 60 pcs.)
Shrink tubing for battery (BSF7)
Special case for press the O-ring seals in the BSF8 case
Gauge for bending the 1/2 AAbattery cable