Spirent C1 Manuel utilisateur

Spirent C1 Installation Instructions |1
PN 71-008659 Rev A 2/19
Spirent C1 Installation Instructions
Refer to the Release Notes for information on supported software applications, versions,
and NIC configurations.
Note: The terms Spirent C1 and SPT-C1 are used interchangeably in this document.
• Certifications and Standards . . . . 4
• Requirements . . . . 6
• System Description . . . . 9
• Rack Mounting Considerations . . . . 15
• Connecting to the SPT-C1 . . . . 15
• Appliance Firmware Support . . . . 19
• Using Authenticate Mode (optional) . . . . 20
• Related Documentation . . . . 23
• How to Contact Us . . . . 24

Spirent C1 Installation Instructions
2|Spirent C1 Installation Instructions PN 71-008659 Rev A 2/19
Copyright
© 2019 Spirent Communications, Inc. All Rights Reserved.
All of the company names and/or brand names and/or product names referred to in this
document, in particular, the name “Spirent” and its logo device, are either registered
trademarks or trademarks of Spirent plc and its subsidiaries, pending registration in
accordance with relevant national laws. All other registered trademarks or trademarks are
the property of their respective owners. The information contained in this document is
subject to change without notice and does not represent a commitment on the part of
Spirent Communications. The information in this document is believed to be accurate and
reliable, however, Spirent Communications assumes no responsibility or liability for any
errors or inaccuracies that may appear in the document.
Limited Warranty
Spirent Communications, Inc. (“Spirent”) warrants that its Products will conform to the
description on the face of order, that it will convey good title thereto, and that the Product
will be delivered free from any lawful security interest or other lien or encumbrance.
Spirent further warrants to Customer that hardware which it supplies and the tangible
media on which it supplies software will be free from significant defects in materials and
workmanship for a period of twelve (12) months, except as otherwise noted, from the date
of delivery (the “Hardware Warranty Period”), under normal use and conditions.
To the extent the Product is or contains software (“Software”), Spirent also warrants that,
if properly used by Customer in accordance with the Software License Agreement, the
Software which it supplies will operate in material conformity with the specifications
supplied by Spirent for such Software for a period of ninety (90) days from the date of
delivery (the “Software Warranty Period”). The “Product Warranty Period” shall mean the
Hardware Warranty Period or the Software Warranty Period, as applicable. Spirent does
not warrant that the functions contained in the Software will meet a specific requirement
or that the operation will be uninterrupted or error free. Spirent shall have no warranty
obligations whatsoever with respect to any Software which has been modified in any
manner by Customer or any third party.
Defective Products and Software under warranty shall be, at Spirent's discretion, repaired
or replaced or a credit issued to Customer's account for an amount equal to the price paid
for such Product provided that: (a) such Product is returned to Spirent after first obtaining
a return authorization number and shipping instructions, freight prepaid, to Spirent's
location in the United States; (b) Customer provides a written explanation of the defect or
Software failure claimed by Customer; and (c) the claimed defect actually exists and was
not caused by neglect, accident, misuse, improper installation, improper repair, fire, flood,
lightning, power surges, earthquake, or alteration. Spirent will ship repaired Products to
Customer, freight prepaid, based on reasonable best efforts after the receipt of defective
Products. Except as otherwise stated, any claim on account of defective materials or for
any other cause whatsoever will conclusively be deemed waived by Customer unless
written notice thereof is given to Spirent within the Warranty Period. Spirent reserves the

Spirent C1 Installation Instructions
Spirent C1 Installation Instructions |3
PN 71-008659 Rev A 2/19
right to change the warranty and service policy set forth above at any time, after
reasonable notice and without liability to Customer.
TO THE EXTENT PERMITTED BY APPLICABLE LAW, ALL IMPLIED
WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF
MERCHANTABILITY, NONINFRINGEMENT AND FITNESS FOR A PARTICULAR
PURPOSE, ARE HEREBY EXCLUDED, AND THE LIABILITY OF SPIRENT, IF
ANY, FOR DAMAGE RELATING TO ANY ALLEGEDLY DEFECTIVE PRODUCT
SHALL BE LIMITED TO THE ACTUAL PRICE PAID BY THE CUSTOMER FOR
SUCH PRODUCT. THE PROVISIONS SET FORTH ABOVE STATE SPIRENT'S
ENTIRE RESPONSIBILITY AND CUSTOMER'S SOLE AND EXCLUSIVE REMEDY
WITH RESPECT TO ANY BREACH OF ANY WARRANTY.
Safety Precautions
Warning: Calls attention to operating procedures or practices that should be followed to
avoid bodily injury or damage to equipment.
Caution: Reflects conditions that could cause product damage or data loss.
Note: Describes limitations on the use of the equipment or procedure.
No User-Serviceable Parts
Warning: No user-serviceable parts inside. Do not open.
Waarschuwing: Er zijn geen door de gebruiker te vervangen onderdelen. Niet openen.
Attention: Aucune pièce se trouvant à l'intérieur ne peut être réparée ou remplacée par
l'utilisateur. Ne pas ouvrir.
Lasers Warning
Warning: Because invisible radiation may be emitted from the aperture of the port when
no fiber cable is connected, avoid exposure to radiation and do not stare into
open apertures.
Waarschuwing: Aangezien onzichtbare straling vanuit de opening van de poort kan
komen als er geen fiberkabel aangesloten is, dient blootstelling aan straling en het kijken
in open openingen vermeden te worden.
Attention: Avant d'accéder à cet équipement connecté aux lignes électriques, ôter tout
bijou (anneaux, colliers et montres compris). Lorsqu'ils sont branchés à l'alimentation et
reliés à la terre, les objets métalliques chauffent, ce qui peut provoquer des blessures
graves ou souder l'objet métallique aux bornes.
Calibration
At the time of manufacture, all components manufactured by Spirent Communications are
calibrated in accordance with applicable procedures. Spirent Communications equipment
is calibrated using national standards, consensus standards, and ratio-type measurements

Spirent C1 Installation Instructions
Certifications and Standards
4|Spirent C1 Installation Instructions PN 71-008659 Rev A 2/19
based on self-calibration techniques. By design, the equipment has no user adjustments
and does not require further calibration. Products are calibrated within the published
environmental specifications for the products. At the time of shipment, this Spirent
Communications product met its published operating specifications.
Unpacking
Before opening the product carton, examine it for damage. If damage is not visible,
unpack the carton and check contents for damage. Save all packing materials. If damage is
noted, forward an immediate request to the delivering carrier to perform an inspection and
prepare a damage report. Save the container and packing material until contents are
verified.
Concurrently, report the nature and extent of damage to Spirent Communications
Customer Support so that action can be initiated to repair or replace damaged items, or
instructions issued for returning items.
The responsibility of the manufacturer ends with delivery to the first carrier. All claims for
loss, damage, or nondelivery must be made against the delivering carrier within
10 calendar days of receipt of shipment.
Damaged or Missing Equipment
If any equipment is damaged or missing, call (800) 774-7368 or (818) 676-2616
(international) for technical support. Registered users may also access the Spirent
Communications support website at https://support.spirent.com. You may also email
Certifications and Standards
FCC
Spirent C1 complies with the limits for a Class A digital device in accordance with Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when this equipment is operated in a commercial environment.
Operation is subject to the following two conditions:
•This device may not cause harmful interference.
•This device must accept any interference received, including interference that may
cause undesired operation.
This device generates, uses, and can radiate radio frequency energy if not installed and
used in accordance with the instructions in this manual. Operating this equipment in a
residential area is likely to cause harmful interference, and the customer will be required
to rectify the interference at his or her own expense. This product requires the use of
external shielded cables to maintain compliance pursuant to Part 15 of the FCC Rules.

Spirent C1 Installation Instructions
Certifications and Standards
Spirent C1 Installation Instructions |5
PN 71-008659 Rev A 2/19
CE
The CE symbol on the product label (on the back of the box) indicates this network
appliance is compliant with the EMC Directive and Low Voltage Directive of the
European Union. This product meets the following technical standards:
•EN 55022 — “Limits and Methods of Measurement of Radio Interference
Characteristics of Information Technology Equipment”
•EN 55024 — “Limits and methods of measurement of immunity characteristics for
information technology equipment”
•EN 60950 — “Safety of Information Technology Equipment”
TUV
This product carries the cTUVus mark.
Environmental Considerations
This label is on all Spirent-provided electrical and electronic products that are sold and
shipped (see Figure 1).
Figure 1. Waste of Electrical and Electronic Equipment (WEEE) Label
This label indicates that the product contains material that presents an environmental
concern. Spirent encourages users of Spirent-provided electrical and electronic equipment
to not dispose of the labeled products in waste collection units where the waste is destined
for landfills. Electrical and electronic equipment should be collected separately and
recycled, reused, and processed for recovery and waste treatment in accordance with your
local, regional, and federal laws. If you have any questions regarding this labeling, please
contact your Spirent Communications representative.

Spirent C1 Installation Instructions
Requirements
6|Spirent C1 Installation Instructions PN 71-008659 Rev A 2/19
Requirements
This section describes the Spirent C1 (SPT-C1) system requirements, cable requirements,
and network connectivity. Refer to “System Description” on page 9 for component
descriptions.
SPT-C1 System Requirements
SPT-C1 requires standard AC input of 100-240V~, 6A, 50/60Hz.
Supported Applications and NIC Configurations
Refer to the Release Notes for information on supported software applications, versions,
and NIC configurations.
Note: Not all configurations are available for all software applications.
Cable Requirements
You will need customer-supplied cables for connecting the SPT-C1 to your management
network and for connecting the NIC test ports to your system under test. For detailed
cabling information, refer to the sections under “Connector Panel” beginning on page 9.
PC Requirements
Refer to the Release Notes for information on the minimum PC requirements.
Network Connectivity
Note: The terms “management port” and “administrative port” are used interchangeably.
10/100/1000 Base-T Administrative Port
The administrative port must connect to a 10/100/1000 Base-T network. Spirent
Communications recommends the SPT-C1 be connected through a switch and isolated
from your test environment.
Tip: The administrative port can be connected to a different subnet from the test network.
If traffic overwhelms the test network, having the administrative port on a different subnet
enables you to access SPT-C1 and control the test currently running without contending
with a heavily loaded network.

Spirent C1 Installation Instructions
Requirements
Spirent C1 Installation Instructions |7
PN 71-008659 Rev A 2/19
Test Ports
Table 1 lists the NIC configurations for the test ports.
The ports are described under “Connector Panel” on page 9.
Refer to the Release Notes for information on supported software applications, versions,
and NIC configurations. Not all configurations are available for all software applications.
Table 1. NIC Configurations for SPT-C1 Appliance Models
Appliance Model NIC
Part
Number
10/100M Test
Ports
1 GbE Test
Ports
2.5/5GbE
Test Ports
10 GbE Test
Ports
SPT-C1 2 x 10GbE NIC-27 NA NA NA 2
One dual-port
NIC (SFP+
MM fiber)
SPT-C1 4 x 1GbE NIC-33 4*
One quad-port
NIC
(all copper)
4*
One quad-port
NIC
(all copper)
NA NA
SPT-C1 4 x 1GbE NIC-32 4*
One quad-port
NIC
(all copper)
4*
One quad-port
NIC
(all copper)
NA NA
SPT-C1 4 x 1GbE NIC-31 NA 4
One quad-port
NIC (optical
for MMF)
NA NA
SPT-C1 4 x 10/
100M BroadR-
Reach®
NIC-43 4
One quad-port
NIC (via 2
DE9M
connectors)
NA NA NA
SPT-C1 2 x 10GbE
and 4 x 1GbE
NIC-27 and
NIC-33
4*
One quad-port
NIC (all copper)
4*
One quad-port
NIC
(all copper)
NA 2
One dual-port
NIC (SFP+
MM fiber)
SPT-C1 4 x 1GbE
and 802.11 AC
WAVE-1 WiFi
NIC-33 and
NIC-51
4* One quad-
port NIC (all
copper)
4* One quad-
port NIC (all
copper)
NA NA

Spirent C1 Installation Instructions
Requirements
8|Spirent C1 Installation Instructions PN 71-008659 Rev A 2/19
* EEach physical port is configurable for 10/100/1000M operation.
** Each physical port is configurable for 10G/5G/2.5G/1G/100M operation
SPT-C1 4 x 1GbE
and 802.1 ACN
WAVE-1 WiFi
NIC-33 and
NIC-52
4* One quad-
port NIC (all
copper)
4* One quad-
port NIC (all
copper)
NA NA
SPT-C1 4 x 10G/5G/
2.5G/1G/100M
Copper
NIC-63 4** One quad-
port NIC (all
copper)
4** One quad-
port NIC (all
copper)
4** One quad-
port NIC (all
copper)
4** One quad-
port NIC (all
copper)
SPT-C1 4 x 1GbE
and 802.11 AC
WAVE-2 WiFi
NIC-33 and
NIC-56
4* One quad-
port NIC (all
copper)
4* One quad-
port NIC (all
copper)
NA NA
SPT-C1 4 x 1GbE
and 802.11 AC
WAV E -2 Wi Fi
NIC-33 and
NIC-57
4* One quad-
port NIC (all
copper)
4* One quad-
port NIC (all
copper)
NA NA
SPT-C1 4 x 10G/5G/
2.5G/1G/100M
Copper and 802.11
AC WAVE-2 WiFi
NIC-63 and
NIC-57
4** One quad-
port NIC (all
copper)
4** One quad-
port NIC (all
copper)
4** One quad-
port NIC (all
copper)
4** One quad-
port NIC (all
copper)
SPT-C1 4 x 10G/5G/
2.5G/1G/100M
Copper and 802.11
AC WAVE-2 WiFi
NIC-63 and
NIC-60
4** One quad-
port
NIC (all
copper)
4** One quad-
port
NIC (all
copper)
4** One quad-
port
NIC (all
copper)
4** One quad-
port
NIC (all
copper)
Table 1. NIC Configurations for SPT-C1 Appliance Models (continued)
Appliance Model NIC
Part
Number
10/100M Test
Ports
1 GbE Test
Ports
2.5/5GbE
Test Ports
10 GbE Test
Ports

Spirent C1 Installation Instructions
System Description
Spirent C1 Installation Instructions |9
PN 71-008659 Rev A 2/19
System Description
The SPT-C1 hardware is maintenance-free and should not be disassembled. Servicing the
units yourself jeopardizes your warranty.
Connector Panel
This section shows the connector panels and describes the necessary cabling for SPT-C1.
SPT-C1 supports NIC configurations for the test ports, as listed in “Test Ports” on page 7.
SPT-C1 2 x 10GbE
The SPT-C1 2 x 10GbE connector panel is shown in Figure 2.
Figure 2. SPT-C1 2 x 10GbE Connector Panel
The network data cables (customer supplied) connected to these ports must be as follows:
•Ethernet CAT-5 cable for the management port (Eth0)
•Depending on the NIC configuration, the following for the test ports:
•Two test ports (1 and 2)
–Fiber: LC Fiber Optic connector, Multi-Mode Fiber (62.5um or 50um) cable.
SPT-C1 4 x 1GbE (NIC-33)
The connector panel is shown in Figure 3.
Figure 3. SPT-C1 4 x 1GbE Connector Panel (NIC-33)

Spirent C1 Installation Instructions
System Description
10 |Spirent C1 Installation Instructions PN 71-008659 Rev A 2/19
The network data cables (customer supplied) connected to these ports must be as follows:
•Ethernet CAT-5 cable for the management port (Eth0)
•Four test ports (1-4)
• Copper: RJ45 connector, Ethernet CAT-5 cable.
SPT-C1 4 x 1GbE (NIC-32)
The connector panel is shown in Figure 4.
Figure 4. SPT-C1 4 x 1GbE Connector Panel (NIC-32)
The network data cables (customer supplied) connected to these ports must be as follows:
•Ethernet CAT-5 cable for the management port (Eth0)
•Four test ports (1-4)
• Copper: RJ45 connector, Ethernet CAT-5 cable.
SPT-C1 4 x BroadR-Reach®(NIC-43)
The connector panel is shown in Figure 5.
Figure 5. SPT-C1 4 x BroadR-Reach Connector Panel (NIC-43)
Autres manuels pour C1
1
Table des matières
Autres manuels Spirent Matériel réseau

Spirent
Spirent TestCenter Manuel utilisateur

Spirent
Spirent PX3-QSFP-DD-8 Manuel utilisateur

Spirent
Spirent VisionWorks 7562 Guide de l'utilisateur

Spirent
Spirent A2-400 Manuel utilisateur

Spirent
Spirent DLS 6700 Manuel utilisateur

Spirent
Spirent CF400 Manuel utilisateur

Spirent
Spirent B2-800-QD-4-T1S Manuel utilisateur
Manuels Matériel réseau populaires d'autres marques

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Manuel utilisateur

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Manuel utilisateur

Yudor
Yudor YDS-16 Manuel utilisateur

D-Link
D-Link ShareCenter DNS-320L Manuel utilisateur

Samsung
Samsung ES1642dc Instructions d'utilisation

Honeywell Home
Honeywell Home LTEM-PV Instructions de montage