RF Gateway Quick Guide
Model:RF-100
5. RF Gateway Status
5.1 Check Indicator light
Normal operation:
1. Power on 3s, RUN/SER/RF light will flash at the same time and extinguish.
2. Around 6s, RUN light will flash, and system runs normally.
3. Around 30s, SER light will keep on, and RF gateway has conneted to server.
4. Around 10s-3mins, RF light will keep on, and RF gateway has connected to
RF sub-device. (Connection time varies according to different situation.)
6.Abnormal State Processing
If the data on platform is abnormal when the RF Gateway is running, please check
the table below and according to the status of indicator lights to complete a simple
troubleshooting. If it still can not be resolved or indicator lights status do not show
in the table below, please contact Customer Support.
(Note: Please using the following table query after power-on for 3min at least.)
7. If router requires static IP access, please follow the steps here.
7.2 Enter RF gateway WEB page
7.1 Connect RF gateway and computer via cable.
If indicator lights run normally after the installaiton, users can go to download
the APP directly.
Open a browser and enter 169.254.173.207.
Name: admin; Password: SN of RF gateway.
Click Fast Networking and go to IP address setup page, then set router according
to related parameters.
7.3 Set IP address for RF gateway
ImplicationLights Status Description(All lights are single green lights.)
System Running
Status
Communication
status with
server
Communication
status with
RF sub-device
Flash: Normal running;
ON/OFF: Abnormal running.
ON: Connected to server;
OFF: Fail to connect.
ON: Connected to RF sub-device;
OFF: Fail to connect.
RUN
SER
RF
Fault Cause
Fault
Description Solution
Flash
Flash
OFF ON
On OFF
OFF OFF OFF 1.Power connection loosen.
2.RF Gateway abnormal
1.RF sub-device matching
error.
2.RF sub-device has no
power.
3.Long distance between RF
gateway and RF sub-device
or number of through-walls
too much.
1. Connection between RF
gateway and router loosen.
2. IP address is not ob-
tained.
3. Router has no networking.
1. Check power connection and
insert again.
2. Contact customer service.
1. Contact customer service.
2. Check if RF sub-device is powered
on.
3. Change RF gateway installation site.
1. Check the connection between
RF Gateway and router.
2. Check the router settings.
3. Check if the router has access to
the network.
Power supply
abnormal
Communicate with
RF sub-device
abnormal
Communicate with
server abnormal
RUN SER RF
ON/
OFF ON ON 1.Program runs abnormally.
1. Long press the key, and release
when SER light flashes.
2. Power on again.
System runs
abnormally
1.1 Install Cable and Connect to Router.(Please make sure router has normal
networking ability and DHCP is enabled.)
Key-press Status Description Light Status
Long press 5s
Long press 10s
Rebooting the stick logger
Resetting the stick logger
SER lightwill flash after 5s,then release.
SER light will flash after 5s, RF light will flash 5s
later, then release.(Non-professional personnel
do not operate.)
If you operated incorrectly, please contact
customer service for help.
3. Usage Methods and Notices for Reset Button
3.1 Usage methods and key-press descriptions for reset button
RUN SER RF
ETH POWER
PC
1.2 Connect to Power Supply.
Notice:
1. Installation Requirements: Max. distance between RF gate-
way and RF sub-device without shelter is 200m. Through-wall
Ability: 2 reinforced concrete walls (15cm) at max., total
distance is less than 20m.
2. Do not insert power interface reversed.
Notice:
Do not insert power interface reversed.
Product Name:RF Gateway
Model:RF-100
Input:DC 5V 1.5W
Fixed IP:169.254.173.207
SN:1901386965
MAC:004C4D8F9E
1. RF Gateway Installation