Sola ups 520 Manuel utilisateur

USER GUIDE
ups520
750 VA, 1050 VA, 1425 VA, and 2250 VA
A
Company

Important Notice
The UPS ground (earth) conductor carries leakage current from the loads in addition to any
leakage current generated by the UPS. This UPS generates no more than 0.5 mA of current (U
model), or 1 mA of current (A & E model). To limit the total leakage current to 3.5 mA, the
load leakage must be limited to 3 mA on the U model and 2.5 mA on the A & E model. The
three-wire receptacle that you plug the UPS into must have a good (low-impedance) ground
(protective earth) connection to provide a safe path for leakage current.

u p s 5 2 0
®
750 VA, 1050 VA, 1425 VA and 2250 VA
User Guide
STM-0408A
© Copyright 1998, Best Power. All rights reserved.

SOLA Never Stops Innovating
ups
520
Languages
English. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
If You have a question
Customer Support
If you have a question or problem, Table 4, Troubleshooting, may help. If you need
more help, please have your UPS model number and serial number (on the back
label) nearby, and call the SOLA office nearest you (see the SOLA Offices Sec-
tion).SOLA’s service technicians have in-depth knowledge of the UPS and power
problems.
SOLA may tell you the UPS must be returned. If this happens, we will give you a
Return Authorization (RA) number. When you return a SOLA 520 to the factory
for any reason, please use the original packing material in which your unit was
shipped to you. You may be responsible for repair charges for shipping damaged
units which are not packed in SOLA packing material.If you have discarded the
original packing material, please call the nearest SOLA office so that we can ship new
packing material to you. If you have any questions, please feel free to call or fax the
nearest SOLA office. Please do not return your SOLA 520 without calling SOLA.
SOLA will advise you where to ship your SOLA520.

1
SOLA Never Stops Innovating
ups
520
Table of Contents
Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
UPS Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Quick Startup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Installing CheckUPSII Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
BestDock - Installation and Operation of the SNMP Card Option. . . . . . . . . .5
Symbols, LEDs and Audible Beeps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Replacing the Batteries. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Replacement Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Communication Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Appendix A: Adjusting Voltage Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
SOLA Australia Offices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Trademarks
Windows is a registered trademark of Microsoft Corporation.
All other brand and product names are trademarks or registered trademarks of their respective
holders.

2
SOLA Never Stops Innovating
ups
520
Safety Instructions
IMPORTANT SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS!
This User Guide contains important instructions for your SOLA 520 that must be followed
during installation and maintenance of the UPS and batteries.
The installation and use of this product must comply with all national, federal, state, municipal,
or local codes that apply. For assistance, call SOLA Service or your local SOLA office.
If the SOLA 520 unit has been damaged during shipment, call your vendor immediately.
If the SOLA 520 unit is stored, the batteries should be recharged every 6 months. If stored
above 25 °Celsius, recharge the batteries more often.
CAUTION!
Whenever the unit’s On/Off switch is “On,” there may be dangerous voltage present at the
unit’s outlets. This is because the unit’s battery supplies power even if the unit is not plugged
into the wall outlet. The unit contains dangerous voltages.
To reduce the risk of electric shock, install in a temperature-controlled and humidity-
controlled indoor area free of conductive contaminants.
The power supply cord is intended to serve as the disconnect device. The socket-outlet shall
be near the equipment and shall be easily accessible.
All servicing of this equipment must be performed by qualified service personnel.
Before maintenance or repair, all connections must be removed. Before maintenance, repair,
or shipment, the unit must be completely switched off and unplugged or disconnected.

3
SOLA Never Stops Innovating
ups
520
UPS Features
The SOLA 520 provides protection against power problems, including power outages,
brownouts, and sudden increases in power. It also provides spike suppression and line noise
filtering to protect your equipment. Front panel LEDs and an audible alarm keep you aware of
the unit’s status. Use the drawings below to identify features of the unit.
750 VA
1050 VA and 1425 VA
2250 VA
BestDock
(under cover)
Interface Con-
nector (DB9F)Network Surge
Suppression
(RJ-45)
Australian Output
Receptacle
Input Circuit
Breaker
CEE22 Input
Socket
CEE19 Input
Socket
ON/OFF Button
(See “Quick Start”
Page 4)
Alarm Silence Button (See
“Symbols, LEDs and Audible
Alarms” Page 6)
Front Panel LEDs (See “Symbols,
LEDs and Audible Alarms” Page 6)

4
SOLA Never Stops Innovating
ups
520
Quick Startup
1
If your SOLA 520 UPS has a removable power cord, connect the power cord to the back of
the unit. Plug the UPS into a wall outlet. Even if the UPS is turned off, the battery charger
will operate when input power is applied to the UPS.
2
Let the unit charge the battery for at least 8 hours. You may use the unit while the battery
charges, but the battery backup runtime will be reduced until the battery is fully charged.
3
Note: The On/Off button must be pressed and held for about one second to turn the SOLA
520 unit on or off. To start the unit, press and hold the On/Off button (the bottom button on
the front panel). When the unit starts, it will beep, then light all of the front panel lights for a
moment, and then light them one at a time. Next, the UPS will do a battery test. While it
does this test, the battery light , and other lights are on that indicate the amount of charge in
the battery. After the battery test, the top green light should remain on.
If the unit beeps, or if the top light does not remain on even though input power is available
from the wall outlet, go to the Troubleshooting section.
4
Switch off the equipment you want to protect, and plug it into the outlets on the back of the
SOLA 520.
5
Switch on the protected equipment, one at a time. If the UPS beeps an alarm when you start
your equipment, the UPS may be overloaded. See the Troubleshooting section.
The bottom four lights on the front of the UPS show the % of the UPS’s power that your
equipment is using. See Symbols, LEDs and Audible Alarms Section for more information.
6
The Surge Protection jacks will protect network equipment that uses
an RJ-45 connection. Plug the 10BASE-T network connection into the
surge protection jack labeled “IN” on the back of the SOLA 520. Plug
the protected equipment into the surge protection jack labeled “OUT.”
Network cabling is not provided. This connection is optional. It is not
needed to use the SOLA 520.
7
Please fill out the warranty registration card and return it to your local SOLA office.
RJ-45

5
SOLA Never Stops Innovating
ups
520
Installing CheckUPS II Software
Your UPS is supplied with a CD-ROM and communications cable to install and operate Check-
UPS II.
To install CheckUPSII on your computer, follow the installation enclosed with the CD-ROM.
BestDock
TM
Installation and Operation of the SNMPCard Option
The SOLA 520’s BestDock communication slot accepts optional communication cards, like the
internal BestLink SNMP/WEB adapter. The insertion of a card into the BestDock communication
slot replaces the normal communication channel from the SOLA 520’s DB-9 Communication
Port. The DB-9 port becomes the connection point
for configuring the card in the BestDock.

6
SOLA Never Stops Innovating
ups
520
Symbols, LEDs and Audible Alarms
The front panel LEDs and an audible alarm indicate the unit status. The unit beeps whenever the
unit is on battery power or an alarm is present. See Table 3 for information on beep coding.
In the figure below, bucking means that SOLA 520 is reducing high input voltage, and boosting
means SOLA 520 is increasing low input voltage.
AC Line Operation:
A, B, C, and D indicate
per cent of full load.
Battery operation:
A, B, C, and D indicate
battery charge.
A, B, C, & D = 75-100%
A, B, & C = 50-75%
A & B = 25-50%
A = 0-25%
A, B, C & D = 75-100 %
B, C & D = 50-75 %
C & D = 25-50 %
D = 0-25 %; when D
isflashing,lessthan2
minutes of runtime
remain.
A, B, C, & D, with D
flashing, load = 110%
or higher.
A = UPS Fault; Fan Fail or Overcharge
C = UPS shutdown due to output overload.
B = UPS failed the battery test.
B & C = UPS shutdown from communication
at RS-232, remote shutdown or SNMP.
A & B = UPS shutdown due to main relay
failure or short circuit on output.
A & C = UPS over-temperature shut down.
Table des matières
Autres manuels Sola UPS
Manuels UPS populaires d'autres marques

Pylontech
Pylontech Victron & Pylontech US5000 Manuel utilisateur

Tecnoware
Tecnoware EVO DSP PLUS MM 6.8 Manuel utilisateur

Mecer
Mecer ME-1000-WTU Manuel utilisateur

Mustek
Mustek PowerMust 530(B) Plus Manuel d'installation et d'exploitation

Emerson
Emerson Liebert NXL series Manuel utilisateur

MAKELSAN
MAKELSAN BOXER SERIES Manuel utilisateur