Sfere SC2-A470M1 Manuel utilisateur

LoRa Communication Gateway
User Manual
Applied to:
SC2-A470M1
SC2-A868M1
SC2-A915M1
SC2-B470M1
SC2-B868M1
SC2-B915M1
SC2-A470M2
SC2-B470M2

Thank you for selecting products of JIANGSU SFERE ELECTRIC CO., LTD. For your
convenience of purchasing and safely, correctly and efficiently use of this product,
please read this user manual carefully and pay attention to following points when
using this product.
CAUTION:
The device must be installed and maintained by professionals;
The input signal and power supply must be cut off before any internal or
external operation of the device,
A suitable voltage detection device must be always used to confirm that
there is no voltage at all parts of the meter;
The electrical parameters provided to the device must be within the rated
range
The following conditions will cause damage to the device or abnormal operation
of the device:
The voltage of auxiliary power supply is out of range;
The frequency of auxiliary power supply is out of range;
◆The polarity of current or voltage input is incorrect;
The communication plug is removed with the power on;
The terminals are not connected as required.
Please don’t touch the terminals
when the meter is in operation!
The latest version of this manual can be downloaded on our company's homepage,
and some corresponding test software downloads are also provided. If you need
the electronic version of the user manual, please contact our technical service
department.

Content
1. Version information ..............................................................................1
2. Quick start ............................................................................................. 1
3. Product overview ..................................................................................4
3.1 Naming description .................................................................... 4
3.2 Product parameters ....................................................................5
3.3 Interface description .................................................................. 6
3.4 Working indicator ....................................................................... 6
3.5 Dimensions ................................................................................. 7
4. Application Cases ..................................................................................7
4.1 Features of LoRa Solution .......................................................... 7
4.2 Modbus data acquisition ........................................................... 7
5. Product function ................................................................................... 9
5.1 Working mode selection ............................................................ 9
5.2 Parameter configuration ............................................................ 9
5.3 Signal strength indicator .......................................................... 11
5.4 Firmware upgrade .................................................................... 11

1
1. Version information
Version
number
Author
Date
Description
V1.0.0
Ma Longwei
2021.04.23
April 23rd,
2021
Initial version
V1.0.1
Lu
Xiaocheng
2021.05.07
May 7th, 2021
Modify the RS485 baud rate support
range
2. Quick start
SC2, hereinafter referred to as LoRa communication gateway, can realize the
communication between serial port and LoRa. This chapter mainly introduces the
transparent transmission test guidance of the product.
The related software involved is as follows:
SmartHMI :Sfere general-purpose small gateway configuration tool, which
integrates configuration, debugging, and monitoring, is simple and easy to use.
If you have purchased SC2, there will be the following accessories:
Three conditions must be met for the sender and receiver of data transparent
communication:
Same frequency band
Same frequency
Same rate
This example uses the following parameters for configuration:

2
Parameter
LoRa Communication
Gateway A
LoRa Communication
Gateway B
Frequency band
470
470
Frequency
480M
480M
Rate
5.5K
5.5K
(1) Use the USB to 485 tool to connect the LoRa communication gateway A and B
to the serial device (replaced by a PC), install the antenna on the LoRa
communication gateway, and then power on.
(2) Open the SmartHMI software, select the model of DTU--->SC2, and click
Login.
(3) As shown in the figure, click to open the serial port in turn (select the serial

3
port number corresponding to A and B, serial port parameters: 9600, N.8.1),
enter the configuration mode, read the parameters, configure the parameters
in the above table, and update the configuration. After the configuration is
updated successfully, click OK in the pop-up dialog box.
(4) In the SmartHMI debugging information column, LoRa communication
gateway A sends data, and LoRa communication gateway B can receive data.

4
3. Product overview
The LoRa communication gateway uses a serial port for data transmission and
reception, which reduces the threshold for wireless applications and can realize
one-to-one or one-to-many communication.
3.1 Naming description
SC2 -A470 M1
Transmit power:
M1: 100mW
M2: 1W
Frequency band:
470: 470M~510M
868: 848M~888M
915: 895M~935M
Operating voltage:
A:AC/DC 80~270V
B:DC 20~36V

5
3.2 Product parameters
Model
SC2-A470M1
SC2-A868M1
SC2-A915M1
SC2-B470M1
SC2-B868M1
SC2-B915M1
SC2-A470M2
SC2-B470M2
LoRa interface
Working frequency
band
470:470M~510M
868:848M~888M
915:895M~935M
Transmit power
M1:Max. 100mW, M2: Max. 1W
Receiving sensitivity
Hardware parameters
RS485 interface
Baud rate: 1200bps~9600bps
Data format: N.8.1, O.8.1, N.8.2, E.8.1
Operating voltage
AC/DC 80~270V or DC 20~36V
Operating
temperature
-25°C -- 70°C
Storage temperature
-40°C -- 85°C
Relative humidity
≤95%RH, no condensation
Working altitude
≤2000m
Anti-pollution grade
No corrosive gas
Protection level
IP20
Insulation
Signal, power, output terminal to case resistance>100MΩ
Withstand voltage
Input and power supply 2kV, input and output 2kV,
power supply and output 2kV

6
3.3 Interface description
Antenna interface
SMA antenna base (outer screw and inner hole).
RS485 interface
RS485 interface: RS485 has two leads, A and B respectively. When connecting to
the device, A is connected to A, and B is connected to B.
Reset button
Reset button: This button is for restoring factory settings. When the device is in
normal working status, press this button and hold until all the indicators are off and
then release it to restore the device's setting parameters to the factory
configuration status (serial port parameters: 9600, N.8.1).
3.4 Working indicator
Indicator
light
Features
Description
Power Indicator
Always on when the
power input is correct
Communication indicator
Flashing during LoRa data
transmission

7
3.5 Dimensions
4. Application Cases
4.1 Features of LoRa Solution
1. The LoRa communication gateway is a half-duplex communication method
(similar to wired 485). Only one device can send data in the same channel at the
same time, and it does not support multiple slave devices to send data to the host
device at the same time.
2. The LoRa communication method takes a long time in the air and is not suitable
for scenarios with high real-time requirements.
3. The lower the LoRa rate, the longer the transmission distance, the stronger the
anti-interference ability, and the longer it takes to send data.
4.2 Modbus data acquisition
Applicable scenarios: data collection for power meters, water meters, etc.
Applicable mode: transparent transmission mode
Matching products: can be matched with smart wireless power meters
Application details:
Ce manuel convient aux modèles suivants
7
Table des matières
Manuels Porte populaires d'autres marques

LST
LST M500RFE-AS Manuel utilisateur

Kinnex
Kinnex Media Gateway Manuel utilisateur

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuel utilisateur

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuel utilisateur

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuel utilisateur

Telsey
Telsey CPVA 500 - SIP Manuel utilisateur