Keypad beeps Master/Manager
Keypad beeps can be turned off to prevent others hearing
that the lock is being operated.
Command Menu >System >Buzzer >Select On or Off,
press Enter to confirm
Add a User Master/Manager
When a User is added, by default the User has the
privilege to open and audit the lock. If the privilege to
override time delay* is required, it must be specified. The
add user procedure is different for the Manager and
Master.
*If a user is defined as being able to override time delay (TDO Pin Priv),
the feature must be enabled, see Advanced User Instructions.
Manager procedure:
Command Menu >Users >Add >Enter an ID to be added
• Enter a new code, then repeat the new code to confirm
A sub-menu is displayed with user privilege options
> Add >
> Open Priv
> Audit Priv
> TDO Pin Priv
> Add User
• If open and audit privilege is all that is needed, select
Add User, press Enter to confirm
• If privileges must be edited, select each Priv option as
required, press Enter to access. The display shows
either 1 2 3 4 5 or _ _ _ _ _. Each digit or _ represents
a lock ID. 702 Display only uses one lock (ID 1). To
remove privilege from lock 1, press 1 so that it changes
to _. To enable a privilege, press 1 so the _ changes to
1. When complete, press Enter to confirm and return
to the Add user menu.
• Select Add User, press Enter to confirm
Master procedure:
After the new ID is entered, either Standard User or
Manager must be confirmed before the new code is
entered. Unless the Manager has been deleted, only
Standard User should be selected.
Change code All
Opening codes should be changed and tested with the
safe or vault door open where possible.
• Press Arrow Up, Arrow Down or Enter
• Enter a valid ID, and when prompted, enter the
existing code
• Press Arrow Down to scroll so that Change combo is
highlighted, press Enter to confirm
• Enter the new code
• The display shows Confirm, enter the new code again
• The display shows Success
Change code when dual mode is active All
• When dual mode is active, press either Arrow Up,
Arrow Down or Enter to access the command menu,
then scroll to Change combo
• Enter a valid ID, and when prompted, enter the existing
code
• Enter the new code, then repeat the new code to
confirm
Disable or re-enable a User Master/Manager
A user code can be temporarily disabled and then re-
enabled later.
Command Menu >Users >Edit >Enter the ID to be
changed
• Select Status >Select Enable or Disable, press Enter
to confirm
Change User privilege Master/Manager
It is possible to redefine a user’s privilege to disallow or
allow opening, audit or time delay override for each lock
that may be connected to the keypad.
Command Menu >Users >Edit >Enter the ID to be
changed
• Select Privileges, press Enter
A sub-menu is displayed >Privileges
>Open Priv
>Audit Priv
>TDO Pin Priv
>Update User
• Select Open Priv, Audit Priv and TDO Pin Priv and
amend as required using the instruction in Add a User.
• Select Update User, press Enter to confirm
*Only the lock IDs that have been added to Open Priv are available
under TDO Pin Priv.
Delete a User Master/Manager
Command Menu >Users >Delete >Enter the ID to be
deleted
• When the display shows Confirm delete: xx, press
Enter
Reset a User code Master/Manager
If a User has forgotten their code, it is possible to reset it
rather than deleting and adding the User again.
Command Menu >Users >Edit >Reset combo >Enter
the ID to be reset
• Enter the new code, then repeat the new code to
confirm