User/Installation Manual

COPYRIGHT© 2002
SOUNDCRAFT INC.
PRINTED IN U.S.A.

i
TABLE OF CONTENTS
INTRODUCTION & SPECIFICATIONS (SECTION I):
FEATURES OF 28SA-PLUS ....................................... 1
CARD ID NUMBERS AND FACILITY CODES .......... 2
ORDERING ADDITIONAL CARDS ............................ 4
PRODUCT SPECIFICATIONS ................................... 5
INSTALLATION & FACTORY SETTINGS (SECTION II):
INSTALLATION WARNINGS ...................................... 6
GENERAL WIRING INSTRUCTIONS ........................ 6
COMMUNICATIONS WIRING FOR
SINGLE-READER SYSTEMS ..................................... 9
REMOTE READER CONNECTION ......................... 12
CABLE PIN-OUTS AND CONNECTION ................. 13
PHYSICAL INSTALLATION:
SURFACE MOUNT READER ....................... 16
PHYSICAL INSTALLATION:
FLUSH MOUNT READER ............................ 21
PHYSICAL INSTALLATION:
SURFACE METAL HOUSING READER ............. 26
PROGRAMMING (SECTION III):
FACTORY SETTINGS ............................................... 31
PROGRAMMING WITH A PROGRAM DECK ......... 33
PROGRAMMING ACCESS CARDS ............ 35
DOOR CONTROL ........................................ 37
LATCH TIMER ............................................... 38

PRINTER MODE ........................................... 38
ANTIPASSBACK ............................................ 40
DATE & TIME ................................................. 42
LATCH TIMER ............................................... 42
BAUD RATE ................................................... 42
PROGRAMMING WITH SK-NET™ SOFTWARE ........ 43
PROGRAMMING IN TERMINAL MODE .................. 43
USING A PRINTER ................................................... 44
APPENDIX A – WIRING & SYSTEM CONFIGURATION
CONNECTING MULTIPLE 28SA-PLUS UNITS ..... A-1
APPENDIX B – MODEMS
CONNECTING VIA MODEM ................................... B-1
APPENDIX C – LAN CONNECTION
CONNECTING TO A LOCAL AREA NETWORK ....... C-1
APPENDIX D – PREVENTING LIGHTNING DAMAGE
INSTALLING SURGE PROTECTION .................... D-1
ii
V122101 3321090 (5488)

1
SECTION I:
INTRODUCTION
The ENTRACOMP®28SA-Plus is a stand alone card access control system
that will control access to a passageway for 65,000 individuals in 15 weekly
time schedules (Time Zones). Certain Access Cards may be designated as
“Limited Use”cards, and their use may be restricted to allow access for a
given number of days or weeks or for a given number of times.
Programming of cards and most other programming functions are easily
accomplished from outside the unit, using a PD-26 Programming Deck. (A set
of 15 programming cards). The ENTRACOMP®28SA-Plus may also be
programmed with a terminal or PC.Transaction information is stored by the unit
and may be downloaded to a terminal, PC, or serial printer. 5000 transactions
may be stored at one time.
The ENTRACOMP®28SA-Plus has three inputs. Each input may be programmed
by the user to function as a Door Monitor, Tamper Monitor, Remote Open,
Remote Inactive, Bell, Arming Circuit, or User Defined Input. Factory Defaults
for these inputs are 1 - Door Monitor, 2 - Disabled, and 3 - Disabled.
A second “remote”reader (SK-029W) may be added to the ENTRACOMP®
28SA-Plus to control access through a single passageway in both directions.
The ENTRACOMP®28SA-Plus utilizes state of the art electronics in providing
a product that is highly sophisticated, yet inexpensive. Patented slotless
TOUCH CARD®reader technology protects the unit from weather and vandalism.
Simply place the card on the stainless steel TOUCH CARD®reader plate, and
the card is read instantly and accurately -- in any weather. A green light
indicates that access has been granted. Since the ENTRACOMP®28SA-Plus
has non-volatile memory, reprogramming after a power loss is unnecessary.

2
CARD ID NUMBERS AND FACILITY CODES
Access cards used with the 28SA-Plus have two encoded numbers: the ID
number which is different on each card, and the Facility Code, (also called a
system or site code) which is the same for all cards at a given site. ( The
programming cards should also have the same Facility Code.) When a card is
read, the system first verifies the Facility Code, then it checks the ID Number
against its internal “card list”in memory to see if the card is void or valid. It
also checks the Time Zone, the card’s Antipassback status, and the Limited
Use count.
SETTING THE FACILITY (SYSTEM) CODE
IMPORTANT
Before programming or using a new unit,
the correct Facility Code must be set.
When power is first applied, or when the reset button is pushed (see Figure
1) the LED will flash red and green alternately. While the LED is flashing, place
either a Programming Card or an Access Card with the proper facility code
onto the TOUCH CARD®reader plate and remove it (note LED turns solid
green). The ENTRACOMP®28SA-Plus will “remember”the facility code and
retain it until reprogrammed. After setting the facility code, wait for the LED to
stop flashing before attempting to use the program deck to program cards into
the unit.
When placing standard cards on the reader, make sure that the arrow points
up and the logo faces you. The exception is Photo ID cards, where the arrow
points up, and the photo faces you.
To change a facility code (or to set the facility code if the LED is not flashing
red/green) remove the unit from the wall to gain access to the reset button
(see Figure 1). With power still connected, momentarily depress the reset

3
button.The LED indicator will flash red and green alternately. If the reset button
is pushed, but no card is placed on the TOUCH CARD®reader plate before the
LED indicator times out, the system code will be unchanged. In some cases it
may be necessary for the unit to recognize more than one facility code. Typical
instances are when a service technician needs to program a unit and the
original program deck cannot be located, or when other devices such as bar-
code scanners, transmitter-type gate openers or proximity readers are connected
to the remote reader input (particularly if they are 26-bit devices).
FIGURE 1
The ENTRACOMP®28SA-Plus can be set to recognize up to three different
facility codes. To program multiple facility codes, follow the procedure above
for programming a single facility code, but place a card with the second facility
code (and third facility code if necessary) on the TOUCH CARD®reader plate
(or at the remote input device) before the red/green LED indicator times out.

4
Note that it is not generally recommended to combine sets of Secura Key
cards with different facility codes, because the unit cannot distinguish
between access cards having different facility codes and the same ID
number.
ORDERING ADDITIONAL CARDS FOR YOUR SYSTEM
When you wish to add to an existing set of cards, always order additional
cards with the same facility code as your existing cards, and with sequential
(Card ID) numbering starting one number higher than the highest-numbered
card currently in use. It is worth waiting a short time for these cards to be
correctly encoded by the factory, as this will guarantee proper operation and
the highest security for your system.

5
SPECIFICATIONS
PHYSICAL
Surface Housing Flush Housing Metal Housing
Depth 2.25 in (5.72 cm) 1.50 in (3.8 cm) 1.75 in (4.45 cm)
Width 4.00 in (10.16 cm) 5.50 in (13.97 cm) 4.00 in (10.20 cm)
Height 4.60 in (11.70 cm) 7.63 in (19.38 cm) 5.62 in (14.30 cm)
Weight 20 oz (0.57 kg) 18 oz (0.51 kg) 45 oz (1.28 kg)
Material Lexan®(Polycarbonate) All Steel
*Meets UL standard 94 flame retardant rating
POWER REQUIREMENTS
Without Remote Reader 12 to 24 VAC or VDC; 125 mA at 12 VAC
With Remote Reader (SK-029W) 12 to 16 VAC or VDC; 250 mA at 12 VAC
OUTPUTS
Latch & Alarm Shunt DPDT contacts, 115 VAC or 28 VDC, 3A maximum
Tamper (optional) SPDT contact, 115 VAC, 2A maximum
INPUTS
Auxiliary 1, 2, & 3 All require SPST contact closure
COMMUNICATION
RS-232 Serial RS-232. Up to 38.4 kBaud, full duplex,
1 start bit, 8 data bits, 1 stop bit, no parity
RS-485 Requires SK-NM485 module, at 19.2KBaud
Remote Reader 31 bit or 26 bit Wiegand type input.
12 VDC @ 150 mA supplied to remote reader
Modem Requires Hayes compatible - 1200 to 33.6 kBaud
ENVIRONMENT
Ambient Temperature -40oF to 158oF (-40oC to 70oC)
Humidity 0% to 95% relative humidity (non-condensing)
OPERATIONAL
Memory Non-volatile
Card Capacity 65,000
Limited Use Cards 4000
Transaction Storage 5000
Time Zones 15 for card access, 1 door unlock time zone, full week plus
holiday in one-half hour segments; 32 holidays
programmable; selectable automatic daylight savings time
Facility Code Up to 3 different codes simultaneously
Latch/Alarm Shunt Timer Programmable from 1 to 30 seconds (0 = 1/4 second)
Timed Antipassback Programmable from 1 to 30 minutes (hard or soft)
Auxiliary Inputs (3) Programmable for door monitor, tamper monitor, remote
open, remote inactive, bell, arming circuit, or user defined.

6
SECTION II:
INSTALLATION
CAUTION SHOULD BE TAKEN NOT TO TOUCH CIRCUIT BOARD OR
ELECTRONIC COMPONENTS PRIORTO INSTALLATIONTO AVOID ELECTRO-
STATIC DISCHARGE (ESD) DAMAGE.
WARNING
AN EARTH GROUND IS REQUIRED. Connect the green screw on the mounting
plate to a good earth ground (AC Power Ground or a 10 foot copper ground stake)
using a 16AWG solid copper wire. Failure to do so may result in improper
operation or damage to the unit. (See Figures 11 - 21). Flush Mount and Metal
Housing models also have a green ground wire, which must be attached to
the green screw on the mounting plate.
WARNING
DO NOT APPLY POWERTO UNIT UNTIL
ALL CONNECTIONS ARE MADE AND CHECKED
GENERAL WIRING INSTRUCTIONS
For ease of installation and servicing, the ENTRACOMP®28SA-Plus is provided
with a terminal board which is connected to the main unit via a ribbon cable
and connector. The screw terminals on the circuit board will accept wire
gauges #16 through #24, solid or stranded. Strip approximately 5/16" (8mm)
of insulation, insert into the appropriate hole, and tighten with a small
screwdriver. Tinning is strongly recommended for stranded wires (see Figure
2 for proper terminations). Arrange a cable drip loop on all exterior installations.
Autres manuels pour ENTRACOMP 28SA Plus
1
Table des matières
Autres manuels Securakey Porte
Manuels Porte populaires d'autres marques

LST
LST M500RFE-AS Manuel utilisateur

Kinnex
Kinnex Media Gateway Manuel utilisateur

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuel utilisateur

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuel utilisateur

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuel utilisateur

Telsey
Telsey CPVA 500 - SIP Manuel utilisateur