Radio Key® 600 Operating & Installation
Secura Key 1
INTRODUCTION
The Radio Key® 600 is a programmable single-door access control system
which allows any mix of up to 600 Proximity Transponders (Key Tags) or
PIN codes for keypad entry. It can control an electric strike, magnetic lock,
or gate operator, and has an additional input for an exit switch and output
contacts for external alarm shunting. The major components are shown
in Figure 1.
The RK600 Access Control Unit contains the CPU, memory, access
relay, and an internal reader. It has a beeper, bi-color LED indicator and
a 16-position keypad, which is used to add or delete transponders or PIN
codes, to set the operating mode, to program the password and latch timer,
and for PIN entry. The RK600 is weather resistant and is provided with a
gasket for exterior installation.
Parts Supplied:
Access Control Unit
Gasket
MOV
Mounting Plate
Connector/Wire Pigtail
Operating Manual
Quick Start Guide and Wallet Sized Guide
User Log Form
2, 6-32 x 1/2” mounting screws
1, 4-40 x 5/16” Phillips housing screw
1, 4-40 x 5/16” Hex Socket, security housing screw
The RKAR Auxiliary Reader is optional, but recommended for extreme
weather or higher security applications. This reader parallels the internal
reader in the RK600. It contains a bi-color LED indicator and a beeper also
driven by the RK600. A gasket is provided for exterior installation.
The RKAT Audit Trail Module is optional and allows the RK600 to connect
to a PC or Printer for Audit Trail Reporting and programming. RK-LINKTM
Software for Windows® is included.
RK-PS, a 12VDC plug-in power supply is optional. It is designed to power
the RK600 only, and requires 120 VAC input. RK600-BB Back Box / Spacer
is optional. It extends the RK600 out from the mounting surface and provides
additional room for wiring.