REED R2300 Manuel utilisateur

R2300
Instruction
Manual
Infrared
Thermometer
1.888.610.7664info@REED-Direct.com REED-Direct.com

2
Table of Contents
Introduction ................................................................................................ 3
Product Quality........................................................................................... 3
Safety ......................................................................................................... 3
Features...................................................................................................... 4
Specications..........................................................................................4-5
Instrument Description ............................................................................... 5
Display Description .................................................................................... 6
Distance & Spot Size.................................................................................. 7
Operating Instructions...........................................................................8-10
Power ON and OFF................................................................................ 8
Turn Laser Indicator ON and OFF .......................................................... 8
Turn Display Backlight ON and OFF....................................................... 8
Display Maximum and Minimum Temperatures During Measurement... 8
Data Hold Measurement ........................................................................ 8
Entering Setting Mode ........................................................................... 9
Adjusting Emissivity ............................................................................... 9
Switching the Unit of Measure (°F/°C) ................................................... 9
Turning the Alarm Chime ON or OFF ..................................................... 9
Setting the High Temperature Alarm.................................................... 10
Setting the Low Temperature Alarm .................................................... 10
Appendix: Emissivity Chart .................................................................11-12
Fault Diagnostics...................................................................................... 13
Battery Replacement................................................................................ 13
Applications.............................................................................................. 14
Product Care ............................................................................................ 14
Product Warranty ..................................................................................... 14
Product Disposal and Recycling .............................................................. 15
Product Support....................................................................................... 15
1.888.610.7664info@REED-Direct.com REED-Direct.com

3
Introduction
Thank you for purchasing your REED R2300 Infrared Thermometer. Please
read the following instructions carefully before using your instrument. By
following the steps outlined in this manual your meter will provide years of
reliable service.
Product Quality
This product has been manufactured in an ISO9001 facility and has been
calibrated during the manufacturing process to meet stated product
specications. If a certicate of calibration is required please contact the
nearest authorized REED distributor or authorized Service Center. Please
note an additional fee for this service will apply.
Safety
• Neverattempttorepairormodifyyour
instrument. Dismantling your product,
other than for the purpose of replacing
batteries, may cause damage that will
not be covered under the manufac-
turer's warranty. Servicing should only be
provided by an authorized service center.
• Useextremecautionwhenthelaserbeamisturnedon.
• Donotletthebeamenteryoureye,anotherperson'seyeortheeyeof
an animal.
• Becarefulnottopointthebeamoffareectivesurfaceandstrikeyour
eye.
• Donotallowthelaserlightbeamtoimpingeonanygaswhichcan
explode.
1.888.610.7664info@REED-Direct.com REED-Direct.com

4
Features
• Built-inlaserpointeridentiestargetarea
• Userselectable°For°C
• 12:1distancetospotsizeratio
• Digitallyadjustableemissivity
• MaxandMinreadings
• Backlitdisplay
• Highandlowalarms
• Lowbatteryindicationandautoshutoff
Specifications
TemperatureRange: -25.6to752°F(-32to400°C)
Accuracy: ±4°F(2°C)or±2%rdg.
Resolution: 0.1°F(0.1°C)
OpticalResolution(D:S): 12:1
Spectral Response: 8 to 14µm
Emissivity: 0.1to1.0(Adjustable)
Response Time: 500ms
Backlit Display: Yes
DisplayHold: Yes
High/LowAlarms: Yes
AlarmIndicators: Yes(Beeping)
Max/Min: Yes
F/CSwitchable: Yes
LaserType: ClassII
LowBatteryIndicator: Yes
Power Supply: 9V battery
ProductCertications: CE,ETL,RoHS
BatteryLife: Approx.10hours(withcontinuoususe,
backlighton)
continued...
1.888.610.7664info@REED-Direct.com REED-Direct.com

5
OperatingTemperature: 32to104°F(0to40°C)
StorageTemperature: -4to140°F(-20to60°C)
OperatingHumidityRange: <90%
MaximumOperatingAltitude: 6561'(2000m)
MaximumStorageAltitude: 39370'(12000m)
Dimensions: 6.0x4.3x1.6"(153x108x40mm)
Weight: 6.5oz(185g)
Instrument Description
1. LCDDisplay
2. Set Button
3. MAX/MIN/DOWN
Arrow Button
4. Backlight/LaserToggle/
UPArrowButton
2
3
4
5
6
7
8
SET MAX
MIN
5. LaserPointerBeam
6. IR Sensor
7. Trigger
8. Battery Cover
1.888.610.7664info@REED-Direct.com REED-Direct.com

6
Display Description
Emissivity
LaserON
TemperatureMeasurementActive
MeasurementDataHold
MaximumorMinimumValue
LowBattery
Backlight Indicator
UnitofMeasurement
HighandLowLimitAlarm
AlarmOn/Off
1.888.610.7664info@REED-Direct.com REED-Direct.com

7
Distance & Spot Size
1.888.610.7664info@REED-Direct.com REED-Direct.com

8
Operating Instructions
Power ON and OFF
1. Gentlypullthetriggertoturnthethermometeron.TheLCDdisplay
and white backlight will turn on.
2. The thermometer will automatically shut off after 9 seconds of
inactivity.
Turn Laser Indicator ON and OFF
To turn the laser on or off, press and hold the button for 3 seconds.
The icon will appear on the display indicating the laser is on. Press
and hold the button again for 3 seconds and the icon will disap-
pear on the display indicating the laser is now off.
Turn Display Backlight ON and OFF
To turn the display backlight on or off, press the button. The
icon will disappear on the display indicating the backlight is now off. Press
the button again and the icon will reappear on the display and
the backlight will turn on.
Display Maximum and Minimum Temperatures During
Measurement
Press the button to toggle between the maximum and minimum
temperaturemeasurementmodes.WhenthetriggerispulledinMAX
mode, the maximum temperature measurement will show on the display.
WhenthetriggerispulledinMINmode,theminimumtemperature
measurement will show on the display. To resume normal operation, press
and hold the button for 3 seconds.
Data Hold Measurement
Pull and hold the trigger after aiming at the target. The icon will
ash,indicatingthatthetargettemperatureisbeingmeasured.Whenthe
trigger is released, the icon will disappear and the icon will
appear indicating that measurement has stopped and the last measured
temperature will remain on-screen until another measurement is taken.
continued...
1.888.610.7664info@REED-Direct.com REED-Direct.com

9
Entering Setting Mode
Press the trigger and then the SET button to enter the setting mode.
In this mode, a user can choose the desired setting for emissivity, unit
ofmeasure,alarmchimetoggleandHighandLowAlarmvalueadjust-
ment. Once in the setting mode, press the SET button to toggle through
eachmode.Thecorrespondingiconwillashindicatinganadjustment
canbemadefortheselectedparameter.Oncethedesiredadjustments
have been made, press and hold the SET button for 3 seconds to resume
normal operation.
Adjusting Emissivity
WheninSettingMode,the willash,indicatingthevaluecanbe
adjusted.Press to increase the emissivity value by 0.01. Press and hold
the forquickervalueadjustment.Press to decrease the emissivity
value by 0.01. Press and hold the forquickervalueadjustment.Once
thedesiredadjustmentshavebeenmade,pressandholdtheSET button
for 3 seconds to resume normal operation.
Switching the Unit of Measure (°F/°C)
WheninSettingMode,presstheSET button until the or ash,
indicating the value can be modied. Press or to toggle between
Fahrenheit and Celsius. Once the desired unit of measure has been
selected, press and hold the SET button for 3 seconds to save the selec-
tion and resume normal operation.
Turning the Alarm Chime ON or OFF
WheninSettingMode,presstheSET button until the ashes,indi-
catingthehigh/lowalarmchimecanbeadjusted.Press or to turn the
alarmchimeONorOFF.WhenthechimeissettoONthe
will be displayed. When the chime is set to OFF the will be
displayed.Pleasenotethatwhenthechimeisoff,theMAXandMINalarm
icons will still appear on screen when an alarm is triggered. Once the
desired selection has been made, press and hold the SET button for 3
seconds to save the selection and resume normal operation.
continued...
1.888.610.7664info@REED-Direct.com REED-Direct.com

10
Setting the High Temperature Alarm
WheninSettingMode,presstheSETbuttonuntiltheHIGHiconashes,
indicating the value can be modied. Press to increase the tempera-
ture value. Press and hold the forquickervalueadjustment.Press
to decrease the temperature value. Press and hold the for quicker
valueadjustment.Oncethedesiredadjustmentshavebeenmade,press
and hold the SET button for 3 seconds to save the selected high alarm
temperature and resume normal operation.
Setting the Low Temperature Alarm
WheninSettingMode,presstheSETbuttonuntiltheLOWiconashes,
indicating the value can be modied. Press to increase the tempera-
ture value. Press and hold the forquickervalueadjustment.Press to
decrease the temperature value. Press and hold the for quicker value
adjustment.Oncethedesiredadjustmentshavebeenmade,pressand
hold the SET button for 3 seconds to save the selected low alarm temper-
ature and resume normal operation.
1.888.610.7664info@REED-Direct.com REED-Direct.com
Table des matières
Autres manuels REED Thermomètre

REED
REED R2020 Manuel utilisateur

REED
REED R2320 Manuel utilisateur

REED
REED ST-8835 Manuel utilisateur

REED
REED ST-130 Manuel utilisateur

REED
REED R2005 Manuel utilisateur

REED
REED R2020 Manuel utilisateur

REED
REED ST-610B Manuel utilisateur

REED
REED ST-8819 Manuel utilisateur

REED
REED ST-616CT Manuel utilisateur

REED
REED R2002 Manuel utilisateur

REED
REED R2002 Manuel utilisateur

REED
REED R2007 Manuel utilisateur

REED
REED R2001 Manuel utilisateur

REED
REED R2310 Manuel utilisateur

REED
REED SD-947 Manuel utilisateur

REED
REED ST-610B Manuel utilisateur

REED
REED R2400 Manuel utilisateur

REED
REED ST-610B Manuel utilisateur

REED
REED C-370 Manuel utilisateur

REED
REED ST-8839 Manuel utilisateur